• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Sign in Sign up
Upload
Dual, Low-Noise Variable-Gain Amplifier with Preamp (Rev. D)
Dual, Low-Noise Variable-Gain Amplifier with Preamp (Rev. D)

... The LNP offers a high level of flexibility to adapt to a wide range of systems and probes. The LNP gain can be programmed to one of four settings (3dB, 12dB, 18dB, 22dB), while maintaining excellent noise and signal handling characteristics. The input impedance of the LNP can be controlled by select ...
manual
manual

... Important notice: Further, when establishing the direction of rotation of the body or the head of the flashlight we assume that the flashlight is located right in front of you. With your left handing you are holding its head and its body with your right hand. When establishing the direction of rotat ...
Chapter 13
Chapter 13

... the direction of propagation. It will be shown in Sec. 14.2 that such TEM waves propagate along structures composed of pairs of perfect conductors of arbitrary cross­section. The parallel plates shown in Fig. 13.1.1 are a special case of such a pair of conductors. The direction of propagation is alo ...
BIOS Setup - Dell Community
BIOS Setup - Dell Community

... Protection Technology that is used in the processors to segregate areas of memory for use by either storage of code instructions or for storage of data. Enable this feature to prevent malicious software and viruses from taking over the system by inserting malicious code into non-executable memory lo ...
ES51969 - Cyrustek
ES51969 - Cyrustek

... ES51969 provides detection of high-crest-factor (HCF) signal in ACV mode. ES51969 senses the signal and determines it as HCF if the Vpp is large enough. Once the signal is determined as HCF, ES51969 will jump up one measuring range regardless of current measurement value. It takes 60ms to jump one r ...
Universal Transducer Interface (UTI)
Universal Transducer Interface (UTI)

... The sequences of all phases are referred to the first one (phase 1). In this phase, the constant part (or offset) is measured. This phase also contains the synchronization for the microcontroller, since the output frequency in this phase is doubled. During the described measurements, an Intel 87C51F ...
Optical Nanotransmission Lines: Synthesis of Planar Left
Optical Nanotransmission Lines: Synthesis of Planar Left

... voltage applied) or in series (having the same current) configuration, depending on the orientation and polarization of the exciting field. It may be straightforward then to suggest more complex circuits when a system of nano-particles is properly arranged [19]. The circuit model of a “right-handed ...
General Description Features
General Description Features

... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
1 - Microstar
1 - Microstar

... usage outside of its intended role. Most small computers have an RS-232 interface as standard, or easily added, and many peripherals and instruments support its serial interface, but not all in the same way. Hence the application of an RS-232 needs careful study of equipment manufactures connections ...
NTE1739 Integrated Circuit TV Horizontal/Vertical Countdown
NTE1739 Integrated Circuit TV Horizontal/Vertical Countdown

... system looks for the occurrence of a vertical sync pulse: it also adjusts the phase detector gain for the two corresponding vertical windows. The 464th (Pin10 = low) or the 512th (Pin10 = high) clock pulse (at 2fH) from the horizontal divider is used to set the start of the vertical sync window. The ...
General Description Features
General Description Features

... Note 5: Note that the LVDS CWD LO clocks are DC-coupled. This is to ensure immediate synchronization when the clock is first turned on. An AC-coupled LO is problematic in that the RC time constant associated with the coupling capacitors and the input impedance of the pin causes there to be a period ...
Improved Dynamic Model of Fast-Settling Linear-in-dB Automatic Gain Control Circuit
Improved Dynamic Model of Fast-Settling Linear-in-dB Automatic Gain Control Circuit

... characteristic [2]. As a result of this characteristic, an exact analysis of the large-signal settling behavior of the Linear-in-dB circuit is very difficult. Previous authors have used a Taylor series expansion to approximate the exponential function in the overall loop analysis [1, 3-4], which is ...
STV5730A
STV5730A

... Digital Output This is the Red signal output. It is forced low during the horizontal and vertical blanking intervals. G Digital Output This is the Green signal output. It is forced low during the horizontal and vertical blanking intervals. B Digital Output This is the Blue signal output. It is force ...
fiber optics
fiber optics

... applicable and is thoroughly justified because for these fibers, the difference between the core and cladding refractive indices is very small. In other words, the fields in a practical optical fiber are almost transverse in nature and it can be shown that they are linearly polarized. This means tha ...
A practical approach to modal basis selection and wavefront
A practical approach to modal basis selection and wavefront

MAX2035 Ultrasound Variable-Gain Amplifier General Description Features
MAX2035 Ultrasound Variable-Gain Amplifier General Description Features

... The MAX2035 VGA is optimized for less than ±0.5dB absolute gain error to ensure minimal channel-to-channel ultrasound beamforming focus error. The device’s differential outputs are designed to directly drive ultrasound ADCs through an external passive anti-aliasing filter. A switchable clamp is also ...
MAX2037 Ultrasound Variable-Gain Amplifier General Description Features
MAX2037 Ultrasound Variable-Gain Amplifier General Description Features

... The MAX2037 VGA is optimized for less than ±0.25dB absolute gain error to ensure minimal channel-to-channel ultrasound beamforming focus error. The device’s differential outputs are designed to directly drive ultrasound ADCs through an external passive anti-aliasing filter. A switchable clamp is als ...
MAX2037 - Part Number Search
MAX2037 - Part Number Search

... The MAX2037 VGA is optimized for less than ±0.25dB absolute gain error to ensure minimal channel-to-channel ultrasound beamforming focus error. The device’s differential outputs are designed to directly drive ultrasound ADCs through an external passive anti-aliasing filter. A switchable clamp is als ...
Taking Advantage of S-Parameter
Taking Advantage of S-Parameter

... Absolute value/dB ...
CMOS 66 MHz Monolithic 256x24 Color Palette RAM
CMOS 66 MHz Monolithic 256x24 Color Palette RAM

... the blanking level, as shown in Table V. The BLANK signal is latched on the rising edge of CLOCK. While BLANK is at logical zero, the pixel inputs are ignored. Composite sync control input (TTL compatible). A logical zero on the SYNC input switches off a 40 IRE current source on the ISYNC output (se ...
Series 2200/2300 Room Units for Primary Controllers
Series 2200/2300 Room Units for Primary Controllers

... temperature display and output through a bias adjustment. The default value is + 0°F (0°C). Adjustments can be made between -5°F (-3°C) and + 5°F (+3°C), in 0.5°F (1°C) increments. ...
Analysis of Mode-Dependent Gain in Raman Amplified Few-Mode Fiber
Analysis of Mode-Dependent Gain in Raman Amplified Few-Mode Fiber

... minimum value for the error function (max(A± m ) − min(Am )), evaluated over all modes m of interest. In order to minimize the MDG along the whole fiber, the configurations for forward- and backward amplification, have to be optimized individually. However the resulting optimum configuration will be ...
PTN3355
PTN3355

...  1920  1440, 60 Hz, 18 bpp, 234 MHz pixel clock rate  2048  1152, 60 Hz (reduced blanking), 24 bpp, 162 MHz pixel clock rate  2048  1536, 50 Hz (reduced blanking), 24 bpp, 167.2 MHz pixel clock rate  WUXGA: 1920  1200, 60 Hz, 18 bpp, 193 MHz pixel clock rate  WUXGA: 1920  1200, 60 Hz (redu ...
Model
Model

... display. Functions provided include the control of both main and zone input selection, zone source selection, surround mode selection, tuner operation and preset selection. Separate discrete feedback is provided for the Main/Room2 source selection and the Main/Room2 volume level. It is not necessary ...
Defibrillator
Defibrillator

... Leads off / active noise suppression sensing circuit is < 0.1mA DC. The impedance / respiration detector signal frequency is 45 ± 4kHz at 78mA RMS (117mV RMS into an impedance of 1.5kW) pseudo-sinewave. Heart Rate Meter: 20 to 300 BPM. Heart Rate Alarms: User-selectable. Size: 0.125, 0.25, 0.5, 1, 2 ...
1 >

Video Graphics Array



Video Graphics Array (VGA) refers specifically to the display hardware first introduced with the IBM PS/2 line of computers in 1987, but through its widespread adoption has also come to mean either an Amplitude Modulated computer display standard, the 15-pin D-subminiature VGA connector or the 640x480 resolution itself.VGA was the last IBM graphics standard to which the majority of PC clone manufacturers conformed, making it the lowest common denominator that virtually all post-1990 PC graphics hardware can be expected to implement. It was officially followed by IBM's Extended Graphics Array (XGA) standard, but was effectively superseded by numerous slightly different extensions to VGA made by clone manufacturers, collectively known as Super VGA.Today, the VGA analog interface is used for high definition video, including resolutions of 1080p and higher. While the transmission bandwidth of VGA is high enough to support even higher resolution playback, there can be picture quality degradation depending on cable quality and length. How discernible this degradation is depends on the individual's eyesight and the display, though it is more noticeable when switching to and from digital inputs like HDMI or DVI.
  • studyres.com © 2023
  • DMCA
  • Privacy
  • Terms
  • Report