• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Model 1800 Manual
Model 1800 Manual

MECHANIC MEDICAL ELECTRONICS Central Staff Training and Research Institute
MECHANIC MEDICAL ELECTRONICS Central Staff Training and Research Institute

... Measure the indicator coil voltage corresponding to different measurements. Assemble and test the meter Dismantle Digital Multimeter and Identify components /ICs/sections and Trace circuit path for measurement of V, I (AC & DC) & R. Measure the Signal voltage to the display IC corresponding to diffe ...
Performance Characteristics of Sensors and Actuators
Performance Characteristics of Sensors and Actuators

SSE Shunt/Static Exciter/Regulators
SSE Shunt/Static Exciter/Regulators

LMC6001 Ultra Ultra-Low Input Current Amplifier (Rev. I)
LMC6001 Ultra Ultra-Low Input Current Amplifier (Rev. I)

neil_sense3 - Ece.umd.edu
neil_sense3 - Ece.umd.edu

... The focus of our research program in the first year will be to work closely with the MEMS and Infrared Optical Detector groups at ARL to develop state of the art electronics hardware to interface and control their unique sensors. For the MEMS group it is important to develop the electronics to inter ...
Capacitor Bank Switching with Vacuum Circuit Breakers : pdf
Capacitor Bank Switching with Vacuum Circuit Breakers : pdf

Reduction of Peak Input Currents during Charge Pump
Reduction of Peak Input Currents during Charge Pump

3-phase AC circuits
3-phase AC circuits

Dual 20 V N-Channel NexFET™ Power
Dual 20 V N-Channel NexFET™ Power

... Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been de ...
Active Power Filter Control Strategy With Implicit
Active Power Filter Control Strategy With Implicit

... The proposed control strategy is much simpler to implement than conventional strategies, such as the ones listed in the following. Perhaps, the most widespread method is the average current mode control [12], which presents an outer voltage control loop and an internal current control loop. Large co ...
Slide 1
Slide 1

Superior Pulse Resistor Capability
Superior Pulse Resistor Capability

R s
R s

...  An electrical signal source can be represented in either Thevenin form (a voltage source vs in series with source resistance Rs) or the Norton form (a current source is in parallel with resistance Rs). The Thevenin voltage vs is the open-circuit voltage between the source terminals. The Norton cur ...
View File - UET Taxila
View File - UET Taxila

... In its most basic form, an Inductor is simply a coil of wire. For most coils the current, ( i ) flowing through the coil produces a magnetic flux, ( NΦ ) that is proportional to this flow of electrical current. When electrons flow through a conductor a magnetic flux is developed around the conductor ...
Recent Advances In RF Integrated Circuits
Recent Advances In RF Integrated Circuits

... signal with minimal noise and interference. In addition to the noise figT h e viable I C technology for R F / circuits continues to change. Performance, cost, and time ure (NF) and third intercept point (IP3), the gain, port-to-port isolation, and power dissipation of these circuits impact the to ma ...
Non-invasive Bio-impedance Measurement Using Voltage
Non-invasive Bio-impedance Measurement Using Voltage

Aalborg Universitet Application with Shunt Active Power Filter Embedded
Aalborg Universitet Application with Shunt Active Power Filter Embedded

... where L, C and RLoad are filter inductance, filter capacitance and load respectively. Consequently, bode diagram of the system is presented in Fig. 6. It can be observed that 0 dB is achieved on the fundamental frequency (50Hz). With the proportional term kpv increasing, the gain in low frequency ra ...
Single-Phase Series AC Circuits
Single-Phase Series AC Circuits

... e will have its maximum values when the rate of change of current, di/dt, is at its maximum values. These maximum rates of change occur as the current waveform passes through the zero position. Similarly, e will be zero when the rate of change is zero. This occurs when the current waveform is at its ...
Temperature Transducers
Temperature Transducers

Improving Control Dynamics of PMSM Drive by Estimating Zero
Improving Control Dynamics of PMSM Drive by Estimating Zero

P2 Topic 2 - Using electricity foundation
P2 Topic 2 - Using electricity foundation

... A student sets up an experiment to measure the potential difference (voltage) across a filament lamp. She changes the current through the lamp. The diagram shows the circuit she used. ...
Circuit Testers
Circuit Testers

... Hot on Neutral Term. and Hot Term. Unwired ...
Design and Analysis of High Speed Capacitive Pipeline DACs
Design and Analysis of High Speed Capacitive Pipeline DACs

... charge/discharge switches, and charge redistribution switches. The clock feed-through caused by the data switches is not meaningful because there is always a low time-constant path either to Vref or GND. Unlike this, the feed-through related to the charge switches changes the capacitor voltage when ...
LTM8040 - 36V, 1A uModule LED Driver and Current Source.
LTM8040 - 36V, 1A uModule LED Driver and Current Source.

... state. Circuitry drawing current from the LPWR pin is also disabled. This way, the LTM8040 “remembers” the current sourced from the LEDA output until PWM is pulled high again. This leads to a highly linear relationship between pulse width and output light, allowing for a large and accurate dimming r ...
< 1 ... 817 818 819 820 821 822 823 824 825 ... 2207 >

Resistive opto-isolator



Resistive opto-isolator (RO), also called photoresistive opto-isolator, vactrol (after a genericized trademark introduced by Vactec, Inc. in the 1960s), analog opto-isolator or lamp-coupled photocell, is an optoelectronic device consisting of a source and detector of light, which are optically coupled and electrically isolated from each other. The light source is usually a light-emitting diode (LED), a miniature incandescent lamp, or sometimes a neon lamp, whereas the detector is a semiconductor-based photoresistor made of cadmium selenide (CdSe) or cadmium sulfide (CdS). The source and detector are coupled through a transparent glue or through the air.Electrically, RO is a resistance controlled by the current flowing through the light source. In the dark state, the resistance typically exceeds a few MOhm; when illuminated, it decreases as the inverse of the light intensity. In contrast to the photodiode and phototransistor, the photoresistor can operate in both the AC and DC circuits and have a voltage of several hundred volts across it. The harmonic distortions of the output current by the RO are typically within 0.1% at voltages below 0.5 V.RO is the first and the slowest opto-isolator: its switching time exceeds 1 ms, and for the lamp-based models can reach hundreds of milliseconds. Parasitic capacitance limits the frequency range of the photoresistor by ultrasonic frequencies. Cadmium-based photoresistors exhibit a ""memory effect"": their resistance depends on the illumination history; it also drifts during the illumination and stabilizes within hours, or even weeks for high-sensitivity models. Heating induces irreversible degradation of ROs, whereas cooling to below −25 °C dramatically increases the response time. Therefore, ROs were mostly replaced in the 1970s by the faster and more stable photodiodes and photoresistors. ROs are still used in some sound equipment, guitar amplifiers and analog synthesizers owing to their good electrical isolation, low signal distortion and ease of circuit design.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report