• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
INA19x Current Shunt Monitor −16 V to +80 V Common
INA19x Current Shunt Monitor −16 V to +80 V Common

Optical Through the Air Communication -- Preface
Optical Through the Air Communication -- Preface

Auto-titrating pH Meter
Auto-titrating pH Meter

... Organophosphates (OPs) are among the most toxic substances known. Examples of these compounds are: (1) parathion and paraoxon (as pesticides), and (2) soman, sarin and VX nerve gas (used as chemical warfare agents). These compounds irreversibly inhibit acetylcholine degradation in the human body and ...
Multimeter
Multimeter

... “Artisans must first sharpen their tools to perform well at work.” Several tools are required for exploring the world of electricity. A multimeter is one of these tools. A multimeter, also known as a Volt-Ohm meter (VOM) or multitester, is an instrument that combines the functions of a galvanometer, ...
Lab 6 Series and Parallel Circuits - Lawrence Technological University
Lab 6 Series and Parallel Circuits - Lawrence Technological University

... Figure 9 - Circuit configuration for Series/Parallel combination circuit. Note: The wire configuration is chosen to allow easy measurement of the currents. Let's investigate the current in the circuit. Will there be more current going into one branch or the other? We will measure the two currents an ...
KE2417381744
KE2417381744

Analog Design Challenges in Advanced CMOS Process Node
Analog Design Challenges in Advanced CMOS Process Node

... such as gain boosting, bootstrapping and current cancelation should be used [6]. Unfortunately threshold voltage Vth also changes with transistor dimensions. For these test cases simulation results showed that Vth ranges from 0.57÷0.61V for 350nm and 0.47÷ 0.51V for 65nm process. This results in abs ...
Design Optimization of Bulk Capacitor
Design Optimization of Bulk Capacitor

... - Actual Measurement and Analysis need to be correlated. - Capacitance Deterioration test. - Temperature variation with DC voltage variation. ...
Voltage Detection and Indication by Electric Field Measurement
Voltage Detection and Indication by Electric Field Measurement

... safest work practices are often those that are easiest to implement, recent emphasis has been placed on convenience and ease of use by both those who work on power lines and the voltage detection equipment providers. Generations of electric utility linemen have become familiar with hot stick type vo ...
MAXIM INTEGRATED PRODUCTS
MAXIM INTEGRATED PRODUCTS

... Reliability Report (RR-1N). Current monitor data for the B12/S12 Process results in a FIT rate of 0.10 @ 25°C and 1.73 @ 55°C (eV = 0.8, UCL = 60%). ...
MAX98302 Stereo 2.4W Class D Amplifier General Description Features
MAX98302 Stereo 2.4W Class D Amplifier General Description Features

... The MAX98302 filterless Class D amplifier offers much higher efficiency than Class AB amplifiers. The high efficiency of a Class D amplifier is due to the switching operation of the output stage transistors. Any power loss associated with the Class D output stage is mostly due to the I2R loss of the ...
Bulbs and Batteries
Bulbs and Batteries

... is placed in series with the capacitor. The switch is initially open. At t = 0, the switch is closed. A very long time after the switch is closed, the current in the circuit is 1. nearly zero 2. at a maximum and decreasing 3. nearly constant but non-zero ...
ABB string inverters PVI-5000/6000-TL-OUTD 5 to 6 kW
ABB string inverters PVI-5000/6000-TL-OUTD 5 to 6 kW

... installations producing between 5kW and 20kW. This inverter has a dual input section to process two strings with independent Maximum Power Point Tracking (MPPT), high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as transformerless operation for high pe ...
Software partitioning technique for an RF matching Craig S. Powers
Software partitioning technique for an RF matching Craig S. Powers

resistance questions
resistance questions

Investigating the Transistor
Investigating the Transistor

Typical Conson Specification
Typical Conson Specification

Doc - Greengineerz
Doc - Greengineerz

... The Status LEDs are used to indicate the direction and percentage of throttle and state of calibration. The LEDs may be one of three colors; red, orange or green. Solid green LEDs indicate positive output voltage equal to the input voltage of the Victor-SP. Solid Red LEDs indicate an output voltage ...
TL880P Engineering Data Sheet 575 KB | December 26, 2007
TL880P Engineering Data Sheet 575 KB | December 26, 2007

EXPERIMENT EMC2: RF EMISSION REDUCTION TECHNIQUES
EXPERIMENT EMC2: RF EMISSION REDUCTION TECHNIQUES

Enhanced-safety, linear Li-ion battery charger w
Enhanced-safety, linear Li-ion battery charger w

... the charger. When the internal chip temperature reaches a predefined temperature threshold—for example, 110°C— any further increase of the IC temperature results in reduction of the charge current. This limits the power dissipation and provides thermal protection to the charger. The maximum power di ...
EE 446/646 Photovoltaic Devices III
EE 446/646 Photovoltaic Devices III

... – Decreasing insolation also reduces the open circuit voltage , but it does so following a logarithmic relationship that results in relatively modest changes. ...
SCIPP Internships 2005
SCIPP Internships 2005

... Muon Lifetime Experiment: Design #1 Area of detectors A-D = 15 x 75 cm2 = 1125 cm2 Area of detector B or C = 30 x 75 cm2 = 2250 cm2 Angle subtended by B or C ≈ /2 = 90 Muon Decay times are measured: ...
LM4766 Overture Audio Pwr Amp Series Dual
LM4766 Overture Audio Pwr Amp Series Dual

... which the device is functional, but do not ensure specific performance limits. Electrical Characteristics state DC and AC electrical specifications under particular test conditions which ensure specific performance limits. This assumes that the device is within the Operating Ratings. Specifications ...
Floating Capacitance Multiplier Circuit Using Full
Floating Capacitance Multiplier Circuit Using Full

< 1 ... 1262 1263 1264 1265 1266 1267 1268 1269 1270 ... 2207 >

Resistive opto-isolator



Resistive opto-isolator (RO), also called photoresistive opto-isolator, vactrol (after a genericized trademark introduced by Vactec, Inc. in the 1960s), analog opto-isolator or lamp-coupled photocell, is an optoelectronic device consisting of a source and detector of light, which are optically coupled and electrically isolated from each other. The light source is usually a light-emitting diode (LED), a miniature incandescent lamp, or sometimes a neon lamp, whereas the detector is a semiconductor-based photoresistor made of cadmium selenide (CdSe) or cadmium sulfide (CdS). The source and detector are coupled through a transparent glue or through the air.Electrically, RO is a resistance controlled by the current flowing through the light source. In the dark state, the resistance typically exceeds a few MOhm; when illuminated, it decreases as the inverse of the light intensity. In contrast to the photodiode and phototransistor, the photoresistor can operate in both the AC and DC circuits and have a voltage of several hundred volts across it. The harmonic distortions of the output current by the RO are typically within 0.1% at voltages below 0.5 V.RO is the first and the slowest opto-isolator: its switching time exceeds 1 ms, and for the lamp-based models can reach hundreds of milliseconds. Parasitic capacitance limits the frequency range of the photoresistor by ultrasonic frequencies. Cadmium-based photoresistors exhibit a ""memory effect"": their resistance depends on the illumination history; it also drifts during the illumination and stabilizes within hours, or even weeks for high-sensitivity models. Heating induces irreversible degradation of ROs, whereas cooling to below −25 °C dramatically increases the response time. Therefore, ROs were mostly replaced in the 1970s by the faster and more stable photodiodes and photoresistors. ROs are still used in some sound equipment, guitar amplifiers and analog synthesizers owing to their good electrical isolation, low signal distortion and ease of circuit design.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report