Q.bloxx A109 - Gantner Instruments
... For/backward counter, quadrature counter with reference zero recognition (reset/enable), up to 1 MHz PWM in and output measurement of duty cycle and frequency, output with variable ...
... For/backward counter, quadrature counter with reference zero recognition (reset/enable), up to 1 MHz PWM in and output measurement of duty cycle and frequency, output with variable ...
FPF3040 IntelliMAX™ 20 V-Rated Dual Input Single Output Power-Source-Selector Switch
... The FPF3040 is a 20 V-rated Dual-Input Single-Output (DISO) load switch consisting of two channels of slewrate-controlled, low-on-resistance, N-channel MOSFET switches with protection features. The slew-ratecontrolled turn-on characteristic prevents inrush current and the resulting excessive voltage ...
... The FPF3040 is a 20 V-rated Dual-Input Single-Output (DISO) load switch consisting of two channels of slewrate-controlled, low-on-resistance, N-channel MOSFET switches with protection features. The slew-ratecontrolled turn-on characteristic prevents inrush current and the resulting excessive voltage ...
STEVAL-ISA063V1
... STBB1XX is a fixed frequency, high efficiency DcDC converter capable of providing output voltages ranging from 1.2 V to 5.5 V, and input voltages from 2.0 V to 5.5 V. The STBB1XX device can operate with input voltages higher than, equal to, or lower than the output voltage, making the product suitab ...
... STBB1XX is a fixed frequency, high efficiency DcDC converter capable of providing output voltages ranging from 1.2 V to 5.5 V, and input voltages from 2.0 V to 5.5 V. The STBB1XX device can operate with input voltages higher than, equal to, or lower than the output voltage, making the product suitab ...
MODEL 62000P SERIES Programmable DC Power Supply Key Features:
... example, the output specification for model 62012P-80-60 is 1200W/80V/60A, it allows operating flexibly in various combinations as shown in the figure at the right. As shown conventional power supplies provide the same rated current at all output voltages, however, the 62000P provides greater curren ...
... example, the output specification for model 62012P-80-60 is 1200W/80V/60A, it allows operating flexibly in various combinations as shown in the figure at the right. As shown conventional power supplies provide the same rated current at all output voltages, however, the 62000P provides greater curren ...
non isolated high step-up dc-dc converters adopting
... dc–dc converter is required to boost the low voltage of a PV or fuel cell to a relatively high bus voltage for the downstream dc–ac grid-connected inverter. To integrate the advantages of the high voltage gain of a switched-capacitor (SC) converter and excellent output regulation of a switching-mode ...
... dc–dc converter is required to boost the low voltage of a PV or fuel cell to a relatively high bus voltage for the downstream dc–ac grid-connected inverter. To integrate the advantages of the high voltage gain of a switched-capacitor (SC) converter and excellent output regulation of a switching-mode ...
The DatasheetArchive - Datasheet Search Engine
... available at Pin 2. Pins 2 and 3 are interchangeable. The mixers are doubly balanced to reduce spurious responses. The first and second mixers have conversion gains of 18 dB and 22 dB (typical), respectively, as seen in Figure 6: Mixer gain is stable with respect to supply voltage. For both conversi ...
... available at Pin 2. Pins 2 and 3 are interchangeable. The mixers are doubly balanced to reduce spurious responses. The first and second mixers have conversion gains of 18 dB and 22 dB (typical), respectively, as seen in Figure 6: Mixer gain is stable with respect to supply voltage. For both conversi ...
CA320010EN
... Eaton identifies an energized circuit by the pulsating of its high intensity LED display with its Cooper Power™ series S.T.A.R.™ hot line voltage indicators. These voltage indicators can be used on both 200 A separable connectors and 600 A terminators with a voltage test point. The removable sleeve ...
... Eaton identifies an energized circuit by the pulsating of its high intensity LED display with its Cooper Power™ series S.T.A.R.™ hot line voltage indicators. These voltage indicators can be used on both 200 A separable connectors and 600 A terminators with a voltage test point. The removable sleeve ...
Electric Circuits
... share the total voltage. In parallel, if one element goes out the other elements will remain on. All elements have the same voltage. Is a house wired in series or in parallel? ...
... share the total voltage. In parallel, if one element goes out the other elements will remain on. All elements have the same voltage. Is a house wired in series or in parallel? ...
(a)What is the load regulation?
... 1) A power supply has an output resistance of 25 mW and a full load current of 0.50 A to a 10.0 W load. (a)What is the load regulation? (b)What is the no load output voltage? 2) The input of certain regulator increase by 3.5V. As a result, the output voltage increase by 0.042V. The nominal output 20 ...
... 1) A power supply has an output resistance of 25 mW and a full load current of 0.50 A to a 10.0 W load. (a)What is the load regulation? (b)What is the no load output voltage? 2) The input of certain regulator increase by 3.5V. As a result, the output voltage increase by 0.042V. The nominal output 20 ...
Read AD589 Datasheet
... references (such as S type characteristics), most manufacturers have begun to use a maximum limit error band approach to specify devices. This technique involves measurement of the output at 3, 5, or more different temperatures to guarantee that the output voltage will fall within the given error ba ...
... references (such as S type characteristics), most manufacturers have begun to use a maximum limit error band approach to specify devices. This technique involves measurement of the output at 3, 5, or more different temperatures to guarantee that the output voltage will fall within the given error ba ...
Realization of the fundamental NOR gate using a chaotic circuit
... output of one gate element to easily couple to another gate element as input, so that gates can be ‘‘wired’’ directly into gate arrays implementing compounded logic operations. Now, for a NOR gate implementation, the following must hold true: ...
... output of one gate element to easily couple to another gate element as input, so that gates can be ‘‘wired’’ directly into gate arrays implementing compounded logic operations. Now, for a NOR gate implementation, the following must hold true: ...
DAC1218 DAC1219 12-Bit Binary Multiplying D/A Converter (Rev. A)
... DAC transfer characteristic. It is measured after adjusting for zero and full scale. Linearity error is a parameter intrinsic to the device and cannot be externally adjusted. National’s linearity test (a) and the best straight line test (b) used by other suppliers are illustrated below. The best str ...
... DAC transfer characteristic. It is measured after adjusting for zero and full scale. Linearity error is a parameter intrinsic to the device and cannot be externally adjusted. National’s linearity test (a) and the best straight line test (b) used by other suppliers are illustrated below. The best str ...
Design of a Clap Activated Switch
... terminal, it activates an electromagnet and closes its contacts. These contacts can then switch on larger amounts of current and voltage safely. But a low power transistor is also needed to switch the current for the relay’s coil. ...
... terminal, it activates an electromagnet and closes its contacts. These contacts can then switch on larger amounts of current and voltage safely. But a low power transistor is also needed to switch the current for the relay’s coil. ...
ohm`s Lab
... power source provides coulombs with energy which is measured in ________. The coulombs decrease in energy as they pass through the load, providing the load with energy to create light, heat or perform some sort of action. The connecting wires create a path allowing the coulombs to flow through the c ...
... power source provides coulombs with energy which is measured in ________. The coulombs decrease in energy as they pass through the load, providing the load with energy to create light, heat or perform some sort of action. The connecting wires create a path allowing the coulombs to flow through the c ...
CN-0120
... low distortion logarithmic audio volume control with glitch reduction. The logarithmic taper is achieved by adding resistor R8 between the wiper connection and ground. This method is described in detail in the article “Tack a Log Taper onto a Digital Potentiometer” by Hank Zumbahlen, EDN, 1/20/00. ...
... low distortion logarithmic audio volume control with glitch reduction. The logarithmic taper is achieved by adding resistor R8 between the wiper connection and ground. This method is described in detail in the article “Tack a Log Taper onto a Digital Potentiometer” by Hank Zumbahlen, EDN, 1/20/00. ...
Schmitt trigger
In electronics a Schmitt trigger is a comparator circuit with hysteresis implemented by applying positive feedback to the noninverting input of a comparator or differential amplifier. It is an active circuit which converts an analog input signal to a digital output signal. The circuit is named a ""trigger"" because the output retains its value until the input changes sufficiently to trigger a change. In the non-inverting configuration, when the input is higher than a chosen threshold, the output is high. When the input is below a different (lower) chosen threshold the output is low, and when the input is between the two levels the output retains its value. This dual threshold action is called hysteresis and implies that the Schmitt trigger possesses memory and can act as a bistable multivibrator (latch or flip-flop). There is a close relation between the two kinds of circuits: a Schmitt trigger can be converted into a latch and a latch can be converted into a Schmitt trigger.Schmitt trigger devices are typically used in signal conditioning applications to remove noise from signals used in digital circuits, particularly mechanical contact bounce. They are also used in closed loop negative feedback configurations to implement relaxation oscillators, used in function generators and switching power supplies.