TRANSPAK T713 ™ RTD Input Isolating, Field Configurable
... 4. Connect the input to a calibrated 3-wire resistance source and monitor the output current (refer to terminal wiring). 5. Set the calibrator to the desired minimum temperature. 6. Adjust the coarse zero rotary switch to obtain an output of approximately 4mA or 10mA. Adjust the fine zero for exact ...
... 4. Connect the input to a calibrated 3-wire resistance source and monitor the output current (refer to terminal wiring). 5. Set the calibrator to the desired minimum temperature. 6. Adjust the coarse zero rotary switch to obtain an output of approximately 4mA or 10mA. Adjust the fine zero for exact ...
FLEX /FLEX MINI Panel Meters For Counting Instruments You Can Rely On,
... * 11-36 VDC, 24 VAC input (others 85-250 AC) ...
... * 11-36 VDC, 24 VAC input (others 85-250 AC) ...
DG201 Datasheet
... Using the VREF Terminal The DG201 has an internal voltage divider setting the TTL threshold on the input control lines for V+ equal to +15V. The schematic shown in Figure 4 with nominal resistor values, gives approximately 2.4V on the VREF pin. As the TTL input signal goes from +0.8V to +2.4V, Q 1 a ...
... Using the VREF Terminal The DG201 has an internal voltage divider setting the TTL threshold on the input control lines for V+ equal to +15V. The schematic shown in Figure 4 with nominal resistor values, gives approximately 2.4V on the VREF pin. As the TTL input signal goes from +0.8V to +2.4V, Q 1 a ...
ADCMP606/ADCMP607 Rail-to-Rail, Very Fast, 2.5 V to 5.5 V
... It is also possible to operate the outputs with the internal termination only if greater output swing is desired. This can be especially useful for driving inputs on CMOS devices intended for full swing ECL and PECL, or for generating pseudo PECL levels. To avoid deep saturation of the outputs and r ...
... It is also possible to operate the outputs with the internal termination only if greater output swing is desired. This can be especially useful for driving inputs on CMOS devices intended for full swing ECL and PECL, or for generating pseudo PECL levels. To avoid deep saturation of the outputs and r ...
Difet OPA121 Low Cost Precision OPERATIONAL AMPLIFIER
... external current-limiting resistors to protect their inputs against destructive currents that can flow when input FET gate-to-substrate isolation diodes are forward-biased. Most BIFET amplifiers can be destroyed by the loss of –VCC. ...
... external current-limiting resistors to protect their inputs against destructive currents that can flow when input FET gate-to-substrate isolation diodes are forward-biased. Most BIFET amplifiers can be destroyed by the loss of –VCC. ...
Ultra-Precision CML AnyGate with Internal Input and Output
... 11. Measured with 100mV input swing. See the Timing Diagrams section for definition of parameters. High-frequency AC parameters are guaranteed by design and characterization. 12. Skew is defined for two parts with identical power supply voltages at the same temperature and with no skew of the edges ...
... 11. Measured with 100mV input swing. See the Timing Diagrams section for definition of parameters. High-frequency AC parameters are guaranteed by design and characterization. 12. Skew is defined for two parts with identical power supply voltages at the same temperature and with no skew of the edges ...
Presentation Title Here
... When Vin exceeds a Vcm maximum Vo is forced to an output rail level The op-amp is forced outside of its linear operating range The feedback loop collapses and an input differential voltage develops One clamp diode or the other becomes forward biased and the input bias current can increase tremendous ...
... When Vin exceeds a Vcm maximum Vo is forced to an output rail level The op-amp is forced outside of its linear operating range The feedback loop collapses and an input differential voltage develops One clamp diode or the other becomes forward biased and the input bias current can increase tremendous ...
Lab3
... An important amplifier configuration is known as cascode amplifier. It consists of a commonemitter (CE) stage followed by a common-base (CB) stage as shown in figure 3. The commonemitter configuration presents a relatively high input resistance ( ac 1) * re to the signal source. ...
... An important amplifier configuration is known as cascode amplifier. It consists of a commonemitter (CE) stage followed by a common-base (CB) stage as shown in figure 3. The commonemitter configuration presents a relatively high input resistance ( ac 1) * re to the signal source. ...
High Speed CMOS Optocouplers Technical Data H
... 1. The LED is OFF when the VI is high and ON when VI is low. 2. Device considered a two terminal device; pins 1-4 shorted together and pins 5-8 shorted together. 3. In accordance with UL 1577, for devices with minimum VISO specified at 3750 V rms, each optocoupler is proof-tested by applying an insu ...
... 1. The LED is OFF when the VI is high and ON when VI is low. 2. Device considered a two terminal device; pins 1-4 shorted together and pins 5-8 shorted together. 3. In accordance with UL 1577, for devices with minimum VISO specified at 3750 V rms, each optocoupler is proof-tested by applying an insu ...
NTE2764 Integrated Circuit
... Programming of multiple NTE2764s in parallel with the same data is easily accomplished. All the like inputs are tied together and programmed by applying a low (0) level TTL pulse to the PGM inputs. Programming Inhibit Mode: Programming multiple NTE2764 in parallel with different data is easier with ...
... Programming of multiple NTE2764s in parallel with the same data is easily accomplished. All the like inputs are tied together and programmed by applying a low (0) level TTL pulse to the PGM inputs. Programming Inhibit Mode: Programming multiple NTE2764 in parallel with different data is easier with ...
Signal Conditioning Unit (SCU) Description: The SCU provides
... The SCU provides power to the LED and converts the raw signal from the LED to a programmable pulse output. The SCU has several external controls and indicators. A green POWER indicator is lit whenever power is available to the SCU. A red EVENT indicator lights whenever a trigger is received from the ...
... The SCU provides power to the LED and converts the raw signal from the LED to a programmable pulse output. The SCU has several external controls and indicators. A green POWER indicator is lit whenever power is available to the SCU. A red EVENT indicator lights whenever a trigger is received from the ...
Schmitt trigger
In electronics a Schmitt trigger is a comparator circuit with hysteresis implemented by applying positive feedback to the noninverting input of a comparator or differential amplifier. It is an active circuit which converts an analog input signal to a digital output signal. The circuit is named a ""trigger"" because the output retains its value until the input changes sufficiently to trigger a change. In the non-inverting configuration, when the input is higher than a chosen threshold, the output is high. When the input is below a different (lower) chosen threshold the output is low, and when the input is between the two levels the output retains its value. This dual threshold action is called hysteresis and implies that the Schmitt trigger possesses memory and can act as a bistable multivibrator (latch or flip-flop). There is a close relation between the two kinds of circuits: a Schmitt trigger can be converted into a latch and a latch can be converted into a Schmitt trigger.Schmitt trigger devices are typically used in signal conditioning applications to remove noise from signals used in digital circuits, particularly mechanical contact bounce. They are also used in closed loop negative feedback configurations to implement relaxation oscillators, used in function generators and switching power supplies.