• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
An MSP430F11x1 Sigma-Delta Type Millivolt Meter
An MSP430F11x1 Sigma-Delta Type Millivolt Meter

electrical measurement laboratory
electrical measurement laboratory

... 3. Jewellery, ties and clothing which, in the opinion of the Laboratory Staff, is hazardous must not be worn while working with machinery in the Laboratory. All users must wear full shoes (not sandals) and at least a shirt and full-length trousers. Long hair must be held back securely with a head ba ...
A  MEMS-Based,  High-Resolution Electric-Field  Meter
A MEMS-Based, High-Resolution Electric-Field Meter

... Figure 1-4: Cross-section of the iMEMS process. In the case of the ESF, the released structure is the movable shutter. direct connection reduces parasitic capacitance, which improves the signal-to-noise ratio (SNR) of the device. Co-integration of the MEMS and the circuitry provides high reliability ...
Lecture 2
Lecture 2

arduinoa
arduinoa

ESM-49 96x48 1/8 DIN 00 Process Indicator
ESM-49 96x48 1/8 DIN 00 Process Indicator

... recommended before installation. It is your responsibility to ensure that qualified mechanical and electrical technicians install this product. If there is danger of serious accident resulting from a failure or defect in this unit, power off the system and separate the electrical connection of the d ...
ZXMC10A816N8 Product Summary Features
ZXMC10A816N8 Product Summary Features

... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
An MSP430F11x1 Sigma-Delta Type Millivolt
An MSP430F11x1 Sigma-Delta Type Millivolt

... The overall accuracy of the A/D converter is determined by the accuracy of the 1-bit DAC. The DAC switches between the MSP430’s VCC and GND. The low RDS (on) of the MSP430 port pins, which drives the DAC, insure DAC output levels extremely close to VCC and GND. The accuracy of system VCC that suppli ...
Capacitor
Capacitor

... Electrons cannot directly pass across the dielectric from one plate of the capacitor to the other. When there is a current through a capacitor, electrons accumulate on one plate and electrons are removed from the other plate. This process is commonly called 'charging' the capacitor even though the c ...
TGA2521-SM 数据资料DataSheet下载
TGA2521-SM 数据资料DataSheet下载

... These ratings represent the maximum operable values for this device. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device and / or affect device lifetime. These are stress ratings only, and functional operation of the device at these conditions is no ...
S - Parameter s - HP Memory Project
S - Parameter s - HP Memory Project

... do even at RF frequencies where lead inductance and capacitance make short and open circuits difficult to obtain. At higher frequencies these measurements typically require tuning stubs, separately adjusted at each measurement frequency, to reflect short or open circuit conditions to the device term ...
Braking Resistors
Braking Resistors

... When a drive unit is attempting to rapidly brake a motor "Deceleration Braking Cycle" or when an "overhauling load" condition exists, the spinning motor acts as a generator. This freewheeling condition will force some voltage back into the drive unit (regeneration) which, depending upon the amount o ...
Node Equations
Node Equations

... current directed from left to right in the 25 Ω resistor. We will simplify this equation by doing two things: 1. Multiplying each side by 8 × 25 = 200 to eliminate fractions. 2. Move the terms that don’t involve node voltages to the right side of the equation. The result is 33 v1 − 8 v 2 = −400 ...
Advanced Motion Detector Using PIR Sensors Reference Design
Advanced Motion Detector Using PIR Sensors Reference Design

... which exemplifies the need for amplification. First, the filtering function is necessary to limit the noise bandwidth of the system before reaching the input to the window comparator. Second, the filtering function sets limits for the minimum and maximum speed at which the system will detect movemen ...
Performance of Transmission Lines
Performance of Transmission Lines

... Transmission Lines 10.4 Three-Phase Short Transmission Lines 10.5 Effect of Load p.f. on Regulation and ...
American National Standard
American National Standard

... This is the second edition of the American National Standard, Diagnostic electrocardiographic devices. The standard, which was developed by the AAMI ECG Committee and its Diagnostic Electrocardiograph Subcommittee and first approved in 1983, is based on the fourth draft of a standard for electrocard ...
STUDY OF UPQC FOR POWER QUALITY IMPROVEMENT MIHIR
STUDY OF UPQC FOR POWER QUALITY IMPROVEMENT MIHIR

... load voltage and a pre established reference. The control provides the effective correction of power factor, harmonic distortion, and load voltage regulation. Chellali Benachaiba et al. [14] described DVR principles and voltage restoration methods at the point of common coupling (PCC) and analysed d ...
MB Series - DriverAgent
MB Series - DriverAgent

... Table 2-5. MB Series Output Module Wiring Diagram: STA-MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-17 Table 2-6. MB02 Address Selection Jumpers . . . . . . . . . . . .2-33 Table 3-1. MB30 and MB31 Specifications . . . . . . . . . . . . . .3-4 Table 3-2. MB30 and MB31 Ordering I ...
103_unit_2
103_unit_2

... format table. The number 5 x10-9 Farads could be written as 5 nano Farads and could also be written as 5 nF. The second conversion will be more difficult. Just remember that the number, when converted, should be a whole number and not a decimal number. To convert the scientific notation format into ...
2253i/2253iX Series User Manual
2253i/2253iX Series User Manual

... Always ensure that facility AC input power is de-energized prior to connecting or disconnecting any cable. In normal operation, the operator does not have access to hazardous voltages within the chassis. However, depending on the user’s application configuration, HIGH VOLTAGES HAZARDOUS TO HUMAN SAF ...
Basic Properties Terminology Theory
Basic Properties Terminology Theory

... of thicknesses achievable, more than one voltage gradient value is desired. By altering the composition of the metal oxide additives it is possible to change the grain size “d” and achieve the desired result. A fundamental property of the ZnO varistor is that the voltage drop across a single interfa ...
Analog and digital filters
Analog and digital filters

BDTIC AN2010-01 MA200E12/17_EVAL
BDTIC AN2010-01 MA200E12/17_EVAL

... voltage increases (close to DC-link voltage level). This behaviour can be practically used for short circuit detection and switching-off an IGBT. The short circuit duration time for Infineon 1200 V and 1700 V IGBT modules must not exceed 10µs. During this time the short circuit should be detected an ...
ADA4960-1 数据手册DataSheet 下载
ADA4960-1 数据手册DataSheet 下载

... The ADA4960-1 is a high performance, differential amplifier optimized for RF and IF applications. It achieves better than 63 dB IMD3 performance for frequencies up to and beyond 1 GHz, making it an ideal driver for 8-bit to 10-bit giga-sample analogto-digital converters (ADCs). ...
LTM4606 - High Efficiency Buck-Boost DC/DC uModule
LTM4606 - High Efficiency Buck-Boost DC/DC uModule

... input decoupling capacitance directly between VIN pins and PGND pins. VOUT (Bank 3): Power Output Pins. Apply output load between these pins and PGND pins. Recommend placing output decoupling capacitance directly between these pins and PGND pins (see figure below). PGND (Bank 2): Power Ground Pins f ...
< 1 ... 68 69 70 71 72 73 74 75 76 ... 1187 >

Schmitt trigger



In electronics a Schmitt trigger is a comparator circuit with hysteresis implemented by applying positive feedback to the noninverting input of a comparator or differential amplifier. It is an active circuit which converts an analog input signal to a digital output signal. The circuit is named a ""trigger"" because the output retains its value until the input changes sufficiently to trigger a change. In the non-inverting configuration, when the input is higher than a chosen threshold, the output is high. When the input is below a different (lower) chosen threshold the output is low, and when the input is between the two levels the output retains its value. This dual threshold action is called hysteresis and implies that the Schmitt trigger possesses memory and can act as a bistable multivibrator (latch or flip-flop). There is a close relation between the two kinds of circuits: a Schmitt trigger can be converted into a latch and a latch can be converted into a Schmitt trigger.Schmitt trigger devices are typically used in signal conditioning applications to remove noise from signals used in digital circuits, particularly mechanical contact bounce. They are also used in closed loop negative feedback configurations to implement relaxation oscillators, used in function generators and switching power supplies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report