OPTOTRONIC OTe 10/220-240/700 PC
... The luminaries’ manufacturer is responsible for providing the required clearance and creepage distances and also for the protection against electrical shock, especially for the line and load wires. ...
... The luminaries’ manufacturer is responsible for providing the required clearance and creepage distances and also for the protection against electrical shock, especially for the line and load wires. ...
Datasheet - Microchip
... The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not desig ...
... The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not desig ...
to this file: /twr8-11w
... During HALT, prototype and pre-production DC/DC converters are subjected to progressively higher stress levels induced by thermal cycling, rate of temperature change, vibration, power cycling, product-specific stresses (such as dc voltage variation) and combined environments. The stresses are not mea ...
... During HALT, prototype and pre-production DC/DC converters are subjected to progressively higher stress levels induced by thermal cycling, rate of temperature change, vibration, power cycling, product-specific stresses (such as dc voltage variation) and combined environments. The stresses are not mea ...
Multiphase DC–DC Converters Using a Boost-Half
... output capacitors [2]. The hybridge rectifier has been employed to reduce the diode conduction losses in the low-voltage and high-current applications [3]. An active-clamping technique not only suppresses the surge voltage, but helps to reduce the circulating current and compensate the duty cycle lo ...
... output capacitors [2]. The hybridge rectifier has been employed to reduce the diode conduction losses in the low-voltage and high-current applications [3]. An active-clamping technique not only suppresses the surge voltage, but helps to reduce the circulating current and compensate the duty cycle lo ...
MAX16836 High-Voltage, 350mA, High-Brightness LED Driver with PWM Dimming and 5V Regulator
... ideal for automotive applications. A +5V regulated output provides up to 4mA of current to power external circuitry. In addition, the MAX16836 features thermal and output short-circuit protection. The wide operating voltage range helps protect the MAX16836 against large transients such as those foun ...
... ideal for automotive applications. A +5V regulated output provides up to 4mA of current to power external circuitry. In addition, the MAX16836 features thermal and output short-circuit protection. The wide operating voltage range helps protect the MAX16836 against large transients such as those foun ...
LU3620212028
... resources, turbines employing squirrel cage induction generators (SCIG) have been used since the beginnings. The operation of SCIG demands reactive power, usually provided from the mains and/or by local generation in capacitor banks [4], [5].The changes occur in its mechanical speed due to wind dist ...
... resources, turbines employing squirrel cage induction generators (SCIG) have been used since the beginnings. The operation of SCIG demands reactive power, usually provided from the mains and/or by local generation in capacitor banks [4], [5].The changes occur in its mechanical speed due to wind dist ...
Motor Interfacing with the Handy Board
... stepper, in order for current to flow in opposite directions in each phase (i.e., independent stator winding), the polarity of the voltage applied to the winding must reverse (hence the name, bipolar). In a unipolar stepper, each phase has a center tap, so if current is supplied at the center tap, i ...
... stepper, in order for current to flow in opposite directions in each phase (i.e., independent stator winding), the polarity of the voltage applied to the winding must reverse (hence the name, bipolar). In a unipolar stepper, each phase has a center tap, so if current is supplied at the center tap, i ...
GS2 Sensor (AGS2) - Panasonic Industrial Devices
... • Use surge absorbers as applying the external surge voltage may damage the internal circuit. • Malfunction may occur near electric noises from static electricity, lightning, broadcast or amateur radio stations and mobile phones. • Avoid use in a place where these products come in contact with water ...
... • Use surge absorbers as applying the external surge voltage may damage the internal circuit. • Malfunction may occur near electric noises from static electricity, lightning, broadcast or amateur radio stations and mobile phones. • Avoid use in a place where these products come in contact with water ...
TPS2838 数据资料 dataSheet 下载
... BOOT to PGND (high-side driver ON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to 30 V BOOTLO to PGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to 16 V BOOT to BOOTLO . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
... BOOT to PGND (high-side driver ON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to 30 V BOOTLO to PGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to 16 V BOOT to BOOTLO . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... the buck–boost converter, their output currents are pulsating, thereby causing the corresponding output voltage ripples to tend to be large. As generally acknowledged, to overcome this problem, one way is to use the capacitor with large capacitance and low equivalent series resistance (ESR), another ...
... the buck–boost converter, their output currents are pulsating, thereby causing the corresponding output voltage ripples to tend to be large. As generally acknowledged, to overcome this problem, one way is to use the capacitor with large capacitance and low equivalent series resistance (ESR), another ...
MC34023 - High Speed PWM Controller
... The oscillator frequency is programmed by the values selected for the timing components RT and CT. The RT pin is set to a temperature compensated 3.0 V. By selecting the value of RT, the charge current is set through a current mirror for the timing capacitor CT. This charge current runs continuously ...
... The oscillator frequency is programmed by the values selected for the timing components RT and CT. The RT pin is set to a temperature compensated 3.0 V. By selecting the value of RT, the charge current is set through a current mirror for the timing capacitor CT. This charge current runs continuously ...
FSFR-XS Series — Fairchild Power Switch (FPS™) for Half-Bridge Resonant Converters
... of RT pin are enclosed by the primary current flow pattern on PCB layout. The direction of the magnetic field on the components caused by the primary current flow is changed when the high- and low-side MOSFET turn on by turns. The magnetic fields with opposite directions induce a current through, in ...
... of RT pin are enclosed by the primary current flow pattern on PCB layout. The direction of the magnetic field on the components caused by the primary current flow is changed when the high- and low-side MOSFET turn on by turns. The magnetic fields with opposite directions induce a current through, in ...
MAX6971 16-Port, 36V Constant-Current LED Driver General Description Features
... or more LED supplies. Bypass each supply to GND with a 0.1µF capacitor as close to the MAX6971 as possible. This is normally adequate for static LED driving. For multiplex or PWM applications, it is necessary to add an additional bulk electrolytic capacitor of 4.7µF or more to each supply for every ...
... or more LED supplies. Bypass each supply to GND with a 0.1µF capacitor as close to the MAX6971 as possible. This is normally adequate for static LED driving. For multiplex or PWM applications, it is necessary to add an additional bulk electrolytic capacitor of 4.7µF or more to each supply for every ...
OPA445 High Voltage FET-Input FEATURES DESCRIPTION
... capacitors, or greater, near the power supply pins. Be sure that the capacitors are appropriately rated for the power-supply voltage used. ...
... capacitors, or greater, near the power supply pins. Be sure that the capacitors are appropriately rated for the power-supply voltage used. ...
Holding Dissapearance in RTD-based Quantizers
... Multiple-valued Logic (MVL) circuits are one of the most attractive applications of the Monostable-to-Multistable transition Logic (MML), and they are on the basis of advanced circuits for communications. The operation of such quantizer has two steps: sampling and holding. Once the quantizer samples ...
... Multiple-valued Logic (MVL) circuits are one of the most attractive applications of the Monostable-to-Multistable transition Logic (MML), and they are on the basis of advanced circuits for communications. The operation of such quantizer has two steps: sampling and holding. Once the quantizer samples ...
IoT - L4
... Resolution is 10-bit (1024 values) In other words, 5/1024 = 4.8 mV smallest voltage change you can measure ...
... Resolution is 10-bit (1024 values) In other words, 5/1024 = 4.8 mV smallest voltage change you can measure ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.