Inductive proximity sensors
... 2 models available : / Dual voltage : $ 24…48 V Output 0-10 mA for 3-wire connection, and 4-14 mA for 2wire connection. / Single voltage : $ 24 V Output 0-16 mA for 3-wire connection and 4-20 mA for 2-wire connection ...
... 2 models available : / Dual voltage : $ 24…48 V Output 0-10 mA for 3-wire connection, and 4-14 mA for 2wire connection. / Single voltage : $ 24 V Output 0-16 mA for 3-wire connection and 4-20 mA for 2-wire connection ...
MAX9918/MAX9919/MAX9920 -20V to +75V Input Range, Precision Uni-/Bidirectional, Current-Sense Amplifiers
... board. For detailed information on package thermal considerations, refer to www.maximintegrated.com/thermal-tutorial. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these ...
... board. For detailed information on package thermal considerations, refer to www.maximintegrated.com/thermal-tutorial. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these ...
DMN63D8LDW Product Summary Features
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
ZDT6790 Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
ECE 342 – Jose Schutt-Aine
... Drain currents are determined by symmetry and inspection VGS values are also determined by inspection for all transistors except Q1 and Q2. To determine VGS for Q1 and Q2, we do the following: the equivalent load resistance will consist of ro1 in parallel with ro4 for Q1 and ro2 in parallel with ro5 ...
... Drain currents are determined by symmetry and inspection VGS values are also determined by inspection for all transistors except Q1 and Q2. To determine VGS for Q1 and Q2, we do the following: the equivalent load resistance will consist of ro1 in parallel with ro4 for Q1 and ro2 in parallel with ro5 ...
FUJI IGBT V-IPM APPLICATION MANUAL REH985 September 2012
... • OC and SC are functions to protect the IGBT against breakdown caused by overcurrent or load short-circuit. As these functions are implemented by detection of collector current by detecting elements built in each IGBT, they permit protection against disorder that occurs in any IGBT, and in addition ...
... • OC and SC are functions to protect the IGBT against breakdown caused by overcurrent or load short-circuit. As these functions are implemented by detection of collector current by detecting elements built in each IGBT, they permit protection against disorder that occurs in any IGBT, and in addition ...
Development of Models for Optical Instrument Transformers by
... Dedicated test facilities are developed so that the steady state and transient performances of analog outputs of a magnetic current transformer (CT) and a magnetic voltage transformer (VT) are compared with that of an optical current transformer (OCT) and an optical voltage transformer (OVT) respect ...
... Dedicated test facilities are developed so that the steady state and transient performances of analog outputs of a magnetic current transformer (CT) and a magnetic voltage transformer (VT) are compared with that of an optical current transformer (OCT) and an optical voltage transformer (OVT) respect ...
D1213A-02SOL Features Mechanical Data
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
Maxim Design Support Technical Documents Application Notes
... Switching losses in a converter occur each time that the circuit switches. These losses are independent of the inductor current, and are directly proportional to the switching period. Therefore, it is advantageous to use the longest switching period that allows for proper system operation. However, ...
... Switching losses in a converter occur each time that the circuit switches. These losses are independent of the inductor current, and are directly proportional to the switching period. Therefore, it is advantageous to use the longest switching period that allows for proper system operation. However, ...
The control of VSC-HVDC and its use for large industrial power
... associated with equipment mal-operation. Many industrial loads cause disturbances in the system like equipment starting dips and transients, harmonic distortion and flicker. Industrial loads are also very sensitive to voltage dips and other disturbances originating from the grid. So electric power s ...
... associated with equipment mal-operation. Many industrial loads cause disturbances in the system like equipment starting dips and transients, harmonic distortion and flicker. Industrial loads are also very sensitive to voltage dips and other disturbances originating from the grid. So electric power s ...
Open drain microprocessor reset
... by the magnitude indicated (Reset Threshold Overdrive). The graph indicates the maximum pulse width a negative VCC transient can have without causing a reset pulse. As the magnitude of the transient increases (further below the threshold), the maximum allowable pulse width decreases. Any combination ...
... by the magnitude indicated (Reset Threshold Overdrive). The graph indicates the maximum pulse width a negative VCC transient can have without causing a reset pulse. As the magnitude of the transient increases (further below the threshold), the maximum allowable pulse width decreases. Any combination ...
$doc.title
... † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to ...
... † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to ...
MAX9789/MAX9790 Windows Vista-Compliant, Stereo Class AB Speaker Amplifiers and DirectDrive Headphone Amplifiers
... Separate speaker and headphone amplifier control inputs provide independent shutdown of the speaker and headphone amplifiers, allowing speaker and headphone amplifiers to be active simultaneously, if required. The industry-leading click-and-pop suppression circuitry reduces audible transients during ...
... Separate speaker and headphone amplifier control inputs provide independent shutdown of the speaker and headphone amplifiers, allowing speaker and headphone amplifiers to be active simultaneously, if required. The industry-leading click-and-pop suppression circuitry reduces audible transients during ...
Lecture 2
... transistor and a resistor. (We use the resistor to translate the output current of the circuit into voltage; otherwise the circuit will not be able to provide a voltage gain.) We then analyze and compare the circuits' small-signals gains to understand for what applications they can be suitable. We a ...
... transistor and a resistor. (We use the resistor to translate the output current of the circuit into voltage; otherwise the circuit will not be able to provide a voltage gain.) We then analyze and compare the circuits' small-signals gains to understand for what applications they can be suitable. We a ...
DRT Series
... The DRT2-series Smart Slaves do not just handle the I/O information of field devices. They can also deliver a variety of information to improve the operating efficiency of the producion equipment. With this information a maintenance system can be fed with information to schedule preventive maintenen ...
... The DRT2-series Smart Slaves do not just handle the I/O information of field devices. They can also deliver a variety of information to improve the operating efficiency of the producion equipment. With this information a maintenance system can be fed with information to schedule preventive maintenen ...
SBYV28-50, SBYV28-100, SBYV28-150, SBYV28-200 Soft
... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
AN105 - Current Sense Circuit Collection
... requirement in many electronics systems, and the techniques to do so are as diverse as the applications themselves. This Application Note compiles solutions to current sensing problems and organizes the solutions by general application type. These circuits have been culled from a variety of Linear T ...
... requirement in many electronics systems, and the techniques to do so are as diverse as the applications themselves. This Application Note compiles solutions to current sensing problems and organizes the solutions by general application type. These circuits have been culled from a variety of Linear T ...
D1213A-01LP Features Mechanical Data
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.