Motors and Generators
... GENERAL DISTRIBUTION: Copyright © 2016 by the National Academy for Nuclear Training. Not for sale or for commercial use. This document may be used or reproduced by Academy members and participants. Not for public distribution, delivery to, or reproduction by any third party without the prior agreem ...
... GENERAL DISTRIBUTION: Copyright © 2016 by the National Academy for Nuclear Training. Not for sale or for commercial use. This document may be used or reproduced by Academy members and participants. Not for public distribution, delivery to, or reproduction by any third party without the prior agreem ...
Application Note - Galco Industrial Electronics
... designed to be rugged, low loss and easy to use. Use of advanced processing technologies gives low on-state saturation voltages while maintaining the high switching speed needed for 20kHz operation. The information presented in this section is intended to help users of Powerex IGBT modules apply the ...
... designed to be rugged, low loss and easy to use. Use of advanced processing technologies gives low on-state saturation voltages while maintaining the high switching speed needed for 20kHz operation. The information presented in this section is intended to help users of Powerex IGBT modules apply the ...
FZT855 Features Mechanical Data
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
ZX5T3Z
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
WP016: Lightning and surge protection for wind turbines
... of equipment according to the manufacturer’s instructions. Manufacturers of electrical and electronic components or devices should be able to provide the required information on the immunity level according to the EMC standards. If this is not the case, the wind turbine manufacturer should perform t ...
... of equipment according to the manufacturer’s instructions. Manufacturers of electrical and electronic components or devices should be able to provide the required information on the immunity level according to the EMC standards. If this is not the case, the wind turbine manufacturer should perform t ...
LAE-2012-008-T - MIT Laboratory for Aviation and the Environment
... as 68.43 mN/W was obtained for a d = 21 cm thruster. Dual-stage thrusters were shown to be more e↵ective than its single-stage counterpart of equal total gap length at producing current, leading to a smaller total voltage necessary for producing equal thrust. However, losses involving ion collection ...
... as 68.43 mN/W was obtained for a d = 21 cm thruster. Dual-stage thrusters were shown to be more e↵ective than its single-stage counterpart of equal total gap length at producing current, leading to a smaller total voltage necessary for producing equal thrust. However, losses involving ion collection ...
GP Series Service Manual
... This SERVICE MANUAL has been written and published by Generac to aid our dealers' mechanics and company service personnel when servicing the products described herein. It is assumed that these personnel are familiar with the servicing procedures for these products, or like or similar products manufa ...
... This SERVICE MANUAL has been written and published by Generac to aid our dealers' mechanics and company service personnel when servicing the products described herein. It is assumed that these personnel are familiar with the servicing procedures for these products, or like or similar products manufa ...
High Voltage, Quad-Channel 12-Bit Voltage Output DAC AD5504
... Asynchronous Clear Input. The CLR input is falling edge sensitive. When CLR is low, all LDAC pulses are ignored. When CLR is activated, the input register and the DAC register are set to 0x000 and the outputs to zero scale. Falling Edge Synchronization Signal. This is the frame synchronization signa ...
... Asynchronous Clear Input. The CLR input is falling edge sensitive. When CLR is low, all LDAC pulses are ignored. When CLR is activated, the input register and the DAC register are set to 0x000 and the outputs to zero scale. Falling Edge Synchronization Signal. This is the frame synchronization signa ...
Chapter 22 Performing Behavioral Modeling
... sources that may be configured to emulate op-amps, single- or multi-input logic gates, or any system with a continuous algebraic transfer function. These functions may be in algebraic form or in the form of coordinate pairs. Digital stimulus files are useful features that allow you to enter a number ...
... sources that may be configured to emulate op-amps, single- or multi-input logic gates, or any system with a continuous algebraic transfer function. These functions may be in algebraic form or in the form of coordinate pairs. Digital stimulus files are useful features that allow you to enter a number ...
Customer Guideline 7542‐2009‐3 KWHDG‐2 0
... K-W Hydro uses voltage regulating devices in the distribution system in order to maintain an adequate voltage profile along the feeders under various operating conditions. These voltage regulating devices include the under-load tap changers at the transformer stations and the voltage regulators or u ...
... K-W Hydro uses voltage regulating devices in the distribution system in order to maintain an adequate voltage profile along the feeders under various operating conditions. These voltage regulating devices include the under-load tap changers at the transformer stations and the voltage regulators or u ...
Build a Cool Blue Audio Level Meter for Your Speakers
... In log mode, there is only one range, because the meter covers the full range of dynamic levels on one scale. After lowpass filtering to remove any RF, the audio is rendered by the full-wave precision rectifier into a DC signal. A filter circuit smooths the DC. If peak mode is selected, the filter h ...
... In log mode, there is only one range, because the meter covers the full range of dynamic levels on one scale. After lowpass filtering to remove any RF, the audio is rendered by the full-wave precision rectifier into a DC signal. A filter circuit smooths the DC. If peak mode is selected, the filter h ...
Dual Precision Retriggerable/Resettable Monostable
... In the quiescent state, CX is fully charged to VDD causing the current through resistor RX to be zero. Both comparators are “off” with total device current due only to reverse junction leakages. An added feature of the MC14538B is that the output latch is set via the input trigger without regard to ...
... In the quiescent state, CX is fully charged to VDD causing the current through resistor RX to be zero. Both comparators are “off” with total device current due only to reverse junction leakages. An added feature of the MC14538B is that the output latch is set via the input trigger without regard to ...
ZXTD617MC Features and Benefits Mechanical Data
... express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. ...
... express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. ...
SP206 数据资料DataSheet下载
... Vdd transfer: The fourth phase of the clock connects the negative terminal of C2 to ground, and transfers the generated 10V across C2 to C4, the Vdd storage capacitor. Again, simultaneously with this, the positive side of capacitor C1 is switched to +5V and the negative side is connected to ground, ...
... Vdd transfer: The fourth phase of the clock connects the negative terminal of C2 to ground, and transfers the generated 10V across C2 to C4, the Vdd storage capacitor. Again, simultaneously with this, the positive side of capacitor C1 is switched to +5V and the negative side is connected to ground, ...
PowerPoint
... The disadvantage of the cascode configuration is that the minimum output voltage is now the sum of the saturation voltages of T1 and T2. It must therefore be used with care in low voltage circuits. ELEC 2005 ...
... The disadvantage of the cascode configuration is that the minimum output voltage is now the sum of the saturation voltages of T1 and T2. It must therefore be used with care in low voltage circuits. ELEC 2005 ...
MT-DB-X4 User Guide November 5, 2014
... The MTDBX4 is a development board for the 44pin Atmel AVR XMEGA AU, A, C, and D microcontrollers. The AU (ie: ATxmega128a4u) and C variants support USB device mode. All variants can be powered from USB or from the Vin pin. Two schottky diodes facilitate simple switching (and reversepolarity pro ...
... The MTDBX4 is a development board for the 44pin Atmel AVR XMEGA AU, A, C, and D microcontrollers. The AU (ie: ATxmega128a4u) and C variants support USB device mode. All variants can be powered from USB or from the Vin pin. Two schottky diodes facilitate simple switching (and reversepolarity pro ...
Generator TheoryPDF
... strength of the magnetic field of the rotor. • This is accomplished by controlling the amount of direct current (DC) or excitation current that is supplied to the rotor’s field winding • The excitation current is supplied by the exciter • The stator’s output to the system is a three‐phase alterna ...
... strength of the magnetic field of the rotor. • This is accomplished by controlling the amount of direct current (DC) or excitation current that is supplied to the rotor’s field winding • The excitation current is supplied by the exciter • The stator’s output to the system is a three‐phase alterna ...
ZXTD717MC Features and Benefits Mechanical Data
... express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. ...
... express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. ...
customising a reluctor style distributor (45dm4) hei
... angle of the distributor’s shaft by essentially providing an on-off switching signal as the shaft rotates, however they do not contain useful amplitude information. The reluctor, on the other hand, being a type of AC generator, not only contains the timing information to detect the distributor’s sh ...
... angle of the distributor’s shaft by essentially providing an on-off switching signal as the shaft rotates, however they do not contain useful amplitude information. The reluctor, on the other hand, being a type of AC generator, not only contains the timing information to detect the distributor’s sh ...
nSP5 PCD - Villa Lighting
... dimming incandescent lighting loads, certain line voltage dimmable fluorescent lighting loads, magnetic low voltage (MLV) lighting loads, and electronic low voltage (ELV) lighting loads. Manual switching and adjustment of the dimming level is possible via WallPods or through the nLight SensorView so ...
... dimming incandescent lighting loads, certain line voltage dimmable fluorescent lighting loads, magnetic low voltage (MLV) lighting loads, and electronic low voltage (ELV) lighting loads. Manual switching and adjustment of the dimming level is possible via WallPods or through the nLight SensorView so ...
AD9225 - Analog Devices
... On-Board Sample-and-Hold Amplifier (SHA)—The versatile SHA input can be configured for either single-ended or differential inputs. Out-of-Range (OTR)—The OTR output bit indicates when the input signal is beyond the AD9225’s input range. ...
... On-Board Sample-and-Hold Amplifier (SHA)—The versatile SHA input can be configured for either single-ended or differential inputs. Out-of-Range (OTR)—The OTR output bit indicates when the input signal is beyond the AD9225’s input range. ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.