• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Chapter-10: Design Of Ehvand UHV Sub-Station
Chapter-10: Design Of Ehvand UHV Sub-Station

... The scheme should fit in the planning criteria used to design the connected transmission system. System should be stable if a permanent fault occurs on a line. It is, therefore, important to limit as much as possible the system un-stability caused by outage of line, transformer or generators due to ...
BA3121F
BA3121F

... extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect on the conduction through the transistor and cause unexpected operation of the IC. So unless otherwise specified, ...
40-A, 8-V to 14-V Input, 3-V to 5.25-V Output, Non
40-A, 8-V to 14-V Input, 3-V to 5.25-V Output, Non

Negative-Sequence Impedance Directional Element
Negative-Sequence Impedance Directional Element

... A-phase current (and the resulting negative-sequence current) would be 180 degrees out-of-phase with the previous example. This would result in a negative torque and a reverse directional declaration. This directional element has been used quite successfully for many years. However, it can be shown ...
IEEE Generator Protection - Levine Lectronics and Lectric
IEEE Generator Protection - Levine Lectronics and Lectric

... • Protects all of the stator winding – Existing schemes typically only see 90% – Stop low level fault near neutral from degrading into a high level fault and causing large amounts of damage – Very secure ...
Aalborg Universitet Electronics-Based Power Systems
Aalborg Universitet Electronics-Based Power Systems

Casco diode - the key to high PFC efficiency BYC58X-600
Casco diode - the key to high PFC efficiency BYC58X-600

... Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights. ...
Presentation Slides
Presentation Slides

... The CPU will do the following things: • Read in a utility (AC) voltage signal • Read in a battery voltage signal • Control the switching of the power source switch • Control the switching of the charging switch • Output a battery life signal to the display ...
LTC4370 - Two-Supply Diode-OR Current
LTC4370 - Two-Supply Diode-OR Current

... 10μA internal pull-up current source into this resistor sets the pin voltage VRANGE. The two supplies will typically share the load current if their voltage difference is within ±VRANGE. The maximum sharing range is ±0.6V, obtained by leaving RANGE open. Connecting this pin to VCC disables load shar ...
Technical Article 650V TRENCHSTOP 5
Technical Article 650V TRENCHSTOP 5

... IGBT that can achieve a considerable improvement in the highlighted PFC topology above. Furthermore, the overshoot and EMC behavior is on the same level as the well-known HighSpeed 3 series. The H5 with the Rapid diode as the free-wheeling diode offers an ease-ofuse solution for high performance har ...
MSi2500 - Mirics.com
MSi2500 - Mirics.com

... during device boot. GPIO_0 receives output data from the EEPROM, whereas GPIO_1 controls the EEPROM chip-select line during the boot sequence. A pull-up or pull-down resistor should be fitted on GPIO_2 to specify which EEPROM size is being used in the application circuit. This allows support for bot ...
IDT8P34S1102I Final Data Sheet.fm
IDT8P34S1102I Final Data Sheet.fm

... Wiring the Differential Input to Accept Single-Ended Levels Figure 1 shows how a differential input can be wired to accept single ended levels. The reference voltage V1= VDD/2 is generated by the bias resistors R1 and R2. The bypass capacitor (C1) is used to help filter noise on the DC bias. This bi ...
LT8608 - 42V, 1.5A Synchronous Step-Down
LT8608 - 42V, 1.5A Synchronous Step-Down

... mode step-down DC/DC converter. An oscillator with frequency set using a resistor on the RT pin turns on the internal top power switch at the beginning of each clock cycle. Current in the inductor then increases until the top switch current comparator trips and turns off the top power switch. The pe ...
MAX11205 16-Bit, Single-Channel, Ultra-Low Power, Delta-Sigma ADC with 2-Wire Serial Interface General Description
MAX11205 16-Bit, Single-Channel, Ultra-Low Power, Delta-Sigma ADC with 2-Wire Serial Interface General Description

... The MAX11205 utilizes power-on reset (POR) supplymonitoring circuitry on both the digital supply (DVDD) and the analog supply (AVDD). The POR circuitry ensures proper device default conditions after either a digital or analog power-sequencing event. The MAX11205 performs a self-calibration operation ...
AAT3603A 数据资料DataSheet下载
AAT3603A 数据资料DataSheet下载

... current, charge termination current, and recharge voltage are programmable with an external resistor and/or by a standard I2C interface. The step-down DC/DC converter is integrated with internal compensation and operates at a switching frequency of 1.5MHz, thus minimizing the size of external compon ...
36-W, Universal Input, >90% Efficiency, Dual Output, Auxiliary
36-W, Universal Input, >90% Efficiency, Dual Output, Auxiliary

... which eliminates the need of current sensing on secondary-side and multiple optocoupler feedback loops for open-loop detection and power limiting. The UCC28740 isolated flyback power supply controller provides CV output regulation using an optical coupler to improve transient response under large lo ...
AD8381 数据手册DataSheet 下载
AD8381 数据手册DataSheet 下载

... permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to the absolute maximum ratings for extended periods may reduce device rel ...
IAS-2002
IAS-2002

... The highest internal surface temperature can generally occur on the surface of the rotor (including the end rings). Rotor temperatures are generally increased when an induction motor is fed from a PWM inverter instead of a sinusoidal voltage source. The difference between the rotor and stator temper ...
BD6046GUL
BD6046GUL

... the common impedance of the wiring patterns. Similarly take pattern design into account for GND lines as well. Furthermore, for all power supply pins of the LSI, in conjunction with inserting capacitors between power supply and GND pins, when using electrolytic capacitors, determine constants upon a ...
Switch-on-to-Fault Schemes in the Context of Line Relay
Switch-on-to-Fault Schemes in the Context of Line Relay

SiT5001 - SiTime
SiT5001 - SiTime

... unauthorized modification or repairs which have been soldered or altered during assembly and are not capable of being tested by SiTime under its normal test conditions, or (iv) improper installation, storage, handling, warehousing or transportation, or (v) being subjected to unusual physical, therma ...
74LCXR2245
74LCXR2245

... ■ Power down high impedance inputs and outputs ■ Supports live insertion/withdrawal(1) ■ ±12mA output drive (VCC = 3.0V) ■ Implements proprietary noise/EMI reduction circuitry ■ Latch-up performance exceeds 500mA ■ Equivalent 26Ω series resistor on all outputs ■ ESD performance: ...
Parameter Display Program
Parameter Display Program

... 'Restart indicator (sets the charged battery indicator to full - 5kWhr 'Used to detect 20Whr increments upon which X is decresed by one. '20Whr x 255 = 5100 Whr (20W x 1 second = 20Whr) 'e.g. 100A at 100V is 10000W for one second is 10000/3600 = 2.78Whr x 7 = 20Whr 'The program cycle is set to run a ...
BD9122GUL
BD9122GUL

... 5. Consideration on Permissible Dissipation and Heat Generation Since this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including l ...
UC2835 数据资料 dataSheet 下载
UC2835 数据资料 dataSheet 下载

... (Surface Mount also Available) ...
< 1 ... 272 273 274 275 276 277 278 279 280 ... 1099 >

Voltage regulator



A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report