DRV8870 3.6-A Brushed DC Motor Driver (PWM
... inputs control the H-bridge driver, which consists of four N-channel MOSFETs that have a typical Rds(on) of 565 mΩ (including one high-side and one low-side FET). A single-power input, VM, serves as both device power and the motor winding bias voltage. The integrated charge pump of the device boosts ...
... inputs control the H-bridge driver, which consists of four N-channel MOSFETs that have a typical Rds(on) of 565 mΩ (including one high-side and one low-side FET). A single-power input, VM, serves as both device power and the motor winding bias voltage. The integrated charge pump of the device boosts ...
电流检测放大器系列ADM1192 数据手册DataSheet 下载
... This is an absolute value to be used when converting ADC codes to current readings; any inaccuracy in this value is factored into absolute current accuracy values (see the specifications for the Current Sense Absolute Accuracy parameter). ...
... This is an absolute value to be used when converting ADC codes to current readings; any inaccuracy in this value is factored into absolute current accuracy values (see the specifications for the Current Sense Absolute Accuracy parameter). ...
A CMOS 33-mW 100-MHz 80-dB SFDR Sample-and-Hold Amplifier PAPER Cheng-Chung HSU
... output voltage swing, noises, and under the constraint of supply voltage. This paper describes the design of a SHA that takes advantage of the parallelism of the timeinterleaved configuration to achieve high-speed and high-resolution performance while reducing power dissipation. The paper is organize ...
... output voltage swing, noises, and under the constraint of supply voltage. This paper describes the design of a SHA that takes advantage of the parallelism of the timeinterleaved configuration to achieve high-speed and high-resolution performance while reducing power dissipation. The paper is organize ...
Linear IC Applications UNIT -1 DIFFERENTIAL AMPLIFIER
... Before jumping into op-amps, let’s first go over some amplifier fundamentals. An amplifier has an input port and an output port. (A port consists of two terminals, one of which is usually connected to the ground node.) In a linear amplifier, the output signal = A input signal, where A is the ampli ...
... Before jumping into op-amps, let’s first go over some amplifier fundamentals. An amplifier has an input port and an output port. (A port consists of two terminals, one of which is usually connected to the ground node.) In a linear amplifier, the output signal = A input signal, where A is the ampli ...
P7000-K MAXON #286121-01 OWNERS MANUAL Date: 01.06.2014
... volts. The difference occurs because of the voltage drop between the battery and the alternator. With this fact in mind, the starting voltage for the liftgate batteries is 13.5 volts. The circuit to charge the liftgate batteries includes the cables from the vehicle's battery box to the dual pole rec ...
... volts. The difference occurs because of the voltage drop between the battery and the alternator. With this fact in mind, the starting voltage for the liftgate batteries is 13.5 volts. The circuit to charge the liftgate batteries includes the cables from the vehicle's battery box to the dual pole rec ...
BDTIC
... The EVAL-2EDL23N06PJ provides an operational amplifier which amplifies the voltage drop over the shunt with a gain of 10. The amplified voltage is available for the user at connector X1 pins A9 and B9. The amplified voltage is calculated with V = Ishunt x Rshunt x 10. Due to inherent component toler ...
... The EVAL-2EDL23N06PJ provides an operational amplifier which amplifies the voltage drop over the shunt with a gain of 10. The amplified voltage is available for the user at connector X1 pins A9 and B9. The amplified voltage is calculated with V = Ishunt x Rshunt x 10. Due to inherent component toler ...
diodes.ies - crazyengg
... the effects that arise due to these time varying signals and the charge separation that exists in the depletion region and in the bulk p and n regions of the diode under forward bias conditions. ...
... the effects that arise due to these time varying signals and the charge separation that exists in the depletion region and in the bulk p and n regions of the diode under forward bias conditions. ...
DIELECTRIC BARRIER DISCHARGES FOR EGG
... The dissipated energy is w = 16 mJ / period. For a frequency f = 13 kHz and a duty cycle δ = 10%, power amounts to P = w f δ = 20.8 W. After a running time of 30 minutes, the inside air temperature is 32o C. If it will take longer times for treatment, the electrodes will have to be cooled. A first a ...
... The dissipated energy is w = 16 mJ / period. For a frequency f = 13 kHz and a duty cycle δ = 10%, power amounts to P = w f δ = 20.8 W. After a running time of 30 minutes, the inside air temperature is 32o C. If it will take longer times for treatment, the electrodes will have to be cooled. A first a ...
manganese titanium lithium rechargeable batteries
... Precautions for handling rechargeable coin type lithium batteries Please observe the following precautions to keep the batteries in good condition. Precautions for storage • Avoid storing batteries at unusually high temperatures. • Store batteries in a low-humidity location with little temperature v ...
... Precautions for handling rechargeable coin type lithium batteries Please observe the following precautions to keep the batteries in good condition. Precautions for storage • Avoid storing batteries at unusually high temperatures. • Store batteries in a low-humidity location with little temperature v ...
BD9102FVM
... Consideration on Permissible Dissipation and Heat Generation Since these ICs function with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including low ...
... Consideration on Permissible Dissipation and Heat Generation Since these ICs function with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including low ...
Motivating Software-Driven Current Balancing in Flexible Voltage-Stacked Multicore Processors
... The most common mechanism for such adaptation is dynamic voltage and frequency scaling (DVFS). Since power and operating frequency scale differently with supply voltage, dynamically adjusting voltage and frequency allows for operation at different points of the power/performance tradeoff space. Howe ...
... The most common mechanism for such adaptation is dynamic voltage and frequency scaling (DVFS). Since power and operating frequency scale differently with supply voltage, dynamically adjusting voltage and frequency allows for operation at different points of the power/performance tradeoff space. Howe ...
fan-aspirated radiation shield
... There is no reference standard for the elimination of radiation effects on air temperature measurement, but well-designed fan-aspirated shields minimize this effect. In the absence of a standard, radiationinduced temperature increase (RITI) was analyzed in long-term experiments over snow and grass s ...
... There is no reference standard for the elimination of radiation effects on air temperature measurement, but well-designed fan-aspirated shields minimize this effect. In the absence of a standard, radiationinduced temperature increase (RITI) was analyzed in long-term experiments over snow and grass s ...
R.M.A. Dawson, M.H. Lu, J.C. Sturm et al, "Impact of transient response of organic light emitting diodes on the design of active matrix OLED displays," Tech. Dig. Int. Elec. Dev. Mtg., pp. 875-878 (1998).
... current versus time is shown in Fig. 2 where there is an initial current peak charging the parallel capacitance followed by a region of constant current determined by the diode. The maximum current shown in Fig. 2 is 7 mA/cm2 which is the peak current level necessary for an active matrix display wit ...
... current versus time is shown in Fig. 2 where there is an initial current peak charging the parallel capacitance followed by a region of constant current determined by the diode. The maximum current shown in Fig. 2 is 7 mA/cm2 which is the peak current level necessary for an active matrix display wit ...
MAX8811 High-Speed, Dual-Phase Driver with Integrated Boost Diodes General Description
... High-Speed, Dual-Phase Driver with Integrated Boost Diodes Principles of Operation MOSFET Gate Drivers (DH_, DL_) DH_ is driven high when the PWM_ is high; DL_ is driven high when PWM_ is low. PWM pulsewidths under 20ns (typ) are rejected, and no switching occurs. The low-side drivers (DL_) have ty ...
... High-Speed, Dual-Phase Driver with Integrated Boost Diodes Principles of Operation MOSFET Gate Drivers (DH_, DL_) DH_ is driven high when the PWM_ is high; DL_ is driven high when PWM_ is low. PWM pulsewidths under 20ns (typ) are rejected, and no switching occurs. The low-side drivers (DL_) have ty ...
Current Source Modular Multilevel Converter for HVDC and FACTS
... To avoid any sensing circuit, control, and/or firing delay, Fig. 6 illustrates another protection scheme against internal open-circuit faults. A back-to-back presspack diode pair is connected in parallel with each switch element in an inductor cell. The diodes must have a lower breakdown voltage tha ...
... To avoid any sensing circuit, control, and/or firing delay, Fig. 6 illustrates another protection scheme against internal open-circuit faults. A back-to-back presspack diode pair is connected in parallel with each switch element in an inductor cell. The diodes must have a lower breakdown voltage tha ...
table of contents - Apogee Instruments
... There is no reference standard for the elimination of radiation effects on air temperature measurement, but well-designed fan-aspirated shields minimize this effect. In the absence of a standard, radiationinduced temperature increase (RITI) was analyzed in long-term experiments over snow and grass s ...
... There is no reference standard for the elimination of radiation effects on air temperature measurement, but well-designed fan-aspirated shields minimize this effect. In the absence of a standard, radiationinduced temperature increase (RITI) was analyzed in long-term experiments over snow and grass s ...
AD650
... phased-locked loop circuits, and precision stepper motor speed controllers. In the F/V mode, the AD650 can be used in precision tachometer and FM demodulator circuits. The input signal range and full-scale output frequency are userprogrammable with two external capacitors and one resistor. Input off ...
... phased-locked loop circuits, and precision stepper motor speed controllers. In the F/V mode, the AD650 can be used in precision tachometer and FM demodulator circuits. The input signal range and full-scale output frequency are userprogrammable with two external capacitors and one resistor. Input off ...
JV2416961699
... signals required for timing in digital circuits and frequency translation in radio frequency Circuits. Their output frequency is a function of a control input usually a voltage. An ideal voltage-controlled voltage oscillator is a circuit whose output frequency is a linear function of its control vol ...
... signals required for timing in digital circuits and frequency translation in radio frequency Circuits. Their output frequency is a function of a control input usually a voltage. An ideal voltage-controlled voltage oscillator is a circuit whose output frequency is a linear function of its control vol ...
OPA3691 Triple Wideband, Current-Feedback OPERATIONAL AMPLIFIER With Disable FEATURES
... The OPA3691 sets a new level of performance for broadband, triple current-feedback op amps. Operating on a very low 5.1mA/ch supply current, the OPA3691 offers a slew rate and output power normally associated with a much higher supply current. A new output stage architecture delivers a high output c ...
... The OPA3691 sets a new level of performance for broadband, triple current-feedback op amps. Operating on a very low 5.1mA/ch supply current, the OPA3691 offers a slew rate and output power normally associated with a much higher supply current. A new output stage architecture delivers a high output c ...
MULTI-BEAM 2-Wire AC Power Block Modules
... MULTI-BEAM 2-wire power blocks offer the ultimate in simplicity of sensor wiring. They wire directly in series with an ac load, exactly like a limit switch. Response time of 2-wire power blocks is determined by the scanner block, whose response time is 10 ms on/off. A built-in false pulse protection ...
... MULTI-BEAM 2-wire power blocks offer the ultimate in simplicity of sensor wiring. They wire directly in series with an ac load, exactly like a limit switch. Response time of 2-wire power blocks is determined by the scanner block, whose response time is 10 ms on/off. A built-in false pulse protection ...
Digital Power Monitor with Convert Pin and ALERTB Output ADM1191
... sense resistor in the power path via the VCC pin and the SENSE pin. A 12-bit ADC can measure the current seen in the sense resistor, as well as the supply voltage on the VCC pin. An industry-standard I2C interface allows a controller to read current and voltage data from the ADC. Measurements can be ...
... sense resistor in the power path via the VCC pin and the SENSE pin. A 12-bit ADC can measure the current seen in the sense resistor, as well as the supply voltage on the VCC pin. An industry-standard I2C interface allows a controller to read current and voltage data from the ADC. Measurements can be ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.