BD14000EFV-C Datasheet
... It is recommended to use a ceramic capacitor with a capacitance equal or greater than 1uF between VREG to VSS. Please select a capacitor with good DC bias characteristics and with a high capacitance value. ...
... It is recommended to use a ceramic capacitor with a capacitance equal or greater than 1uF between VREG to VSS. Please select a capacitor with good DC bias characteristics and with a high capacitance value. ...
AN1404/D ECLinPS™ Circuit Performance at Non
... the input voltages are dropped by an additional VBE (≈800mV) before they are fed into the differential amplifier input gate. The switching reference is also shifted down by one diode drop to remain centered in the input swing. Obviously this input structure will represent the “best case” in the area ...
... the input voltages are dropped by an additional VBE (≈800mV) before they are fed into the differential amplifier input gate. The switching reference is also shifted down by one diode drop to remain centered in the input swing. Obviously this input structure will represent the “best case” in the area ...
SAW Components: Application Note: ESD protection for SAW filters
... A much more critical issue is Electro Static Discharge in a SAWF / SAWR. Interdigital transducers are acting like a capacitor with no DC path between the electrodes. Applying electrostatic energy to the SAWF input (e.g. via antenna) the voltage between the interdigital transducers (IDT) rises and cr ...
... A much more critical issue is Electro Static Discharge in a SAWF / SAWR. Interdigital transducers are acting like a capacitor with no DC path between the electrodes. Applying electrostatic energy to the SAWF input (e.g. via antenna) the voltage between the interdigital transducers (IDT) rises and cr ...
Instructions for Testing and Installing a Voltage
... If the trouble is in the generator, battery or wiring, a new regulator will not correct the fault. Make these tests to determine whether or not a new regulator is needed. If Battery voltage is low and the charging rate is low, or there is no charge at all, make these tests: (1) Check battery water l ...
... If the trouble is in the generator, battery or wiring, a new regulator will not correct the fault. Make these tests to determine whether or not a new regulator is needed. If Battery voltage is low and the charging rate is low, or there is no charge at all, make these tests: (1) Check battery water l ...
PCB manual - Notes Milenge
... at or near full load (i.e. with iron lo-: full load copper loss ratio of 1: 1). Power transformers are designed to have considerable gre: leakage reactance than is permissible in distribution transformers because in power tr: formers inherent voltage regulation is not as much important as current li ...
... at or near full load (i.e. with iron lo-: full load copper loss ratio of 1: 1). Power transformers are designed to have considerable gre: leakage reactance than is permissible in distribution transformers because in power tr: formers inherent voltage regulation is not as much important as current li ...
AAT3608 数据资料DataSheet下载
... package, making it ideal for portable space-constrained systems. The single-input linear charger powers up from an adapter or a USB port. The adapter charge current is programmable with an external resistor or pin selectable between 100mA and 500mA when connected to a USB port. The device integrates ...
... package, making it ideal for portable space-constrained systems. The single-input linear charger powers up from an adapter or a USB port. The adapter charge current is programmable with an external resistor or pin selectable between 100mA and 500mA when connected to a USB port. The device integrates ...
AP1122 1A LOW DROPOUT POSITIVE REGULATOR Description
... 2. See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured at a constant junction temperature by low duty cycle pulse testing. Load regulation is measured at the output lead = 1/18” from the package. 3. Line and load regulatio ...
... 2. See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured at a constant junction temperature by low duty cycle pulse testing. Load regulation is measured at the output lead = 1/18” from the package. 3. Line and load regulatio ...
MAX3967A 270Mbps SFP LED Driver General Description Features
... (VEE, VEEOUT = 0V) ..............................................-0.5V to +7V Current into OUT+, OUT- ................................-40mA to +160mA Differential Output Voltage (OUT+ to OUT-) .........-3.3V to +3.3V Voltage at PB1, PB2, PB3, IN+, IN-, OUT+, OUT-, TX_DISABLE......-0.5V to (VCC + 0.5 ...
... (VEE, VEEOUT = 0V) ..............................................-0.5V to +7V Current into OUT+, OUT- ................................-40mA to +160mA Differential Output Voltage (OUT+ to OUT-) .........-3.3V to +3.3V Voltage at PB1, PB2, PB3, IN+, IN-, OUT+, OUT-, TX_DISABLE......-0.5V to (VCC + 0.5 ...
RTR040N03
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
Aalborg Universitet
... A DG unit can communicate with other DG units by RS232 serial communication. Each DG unit has the opportunity to trigger a synchronization event on the condition that the time interval between two consecutive synchronization events is greater than a permissible minimum value and the output voltage o ...
... A DG unit can communicate with other DG units by RS232 serial communication. Each DG unit has the opportunity to trigger a synchronization event on the condition that the time interval between two consecutive synchronization events is greater than a permissible minimum value and the output voltage o ...
Step-up, step-down, and isolation transformers
... transformer. Explain how the construction of a soldering gun employs a step-down transformer (with a very large step ratio!) to generate high temperatures at the soldering tip. file 02167 Question 30 The ignition coil of a gasoline-powered internal combustion automobile engine is an example of a tra ...
... transformer. Explain how the construction of a soldering gun employs a step-down transformer (with a very large step ratio!) to generate high temperatures at the soldering tip. file 02167 Question 30 The ignition coil of a gasoline-powered internal combustion automobile engine is an example of a tra ...
FAN3268 2 A Low-Voltage PMOS-NMOS Bridge Driver F AN3
... X7R, with good temperature characteristics and high pulse current capability. ...
... X7R, with good temperature characteristics and high pulse current capability. ...
AD8600 数据手册DataSheet 下载
... The output of the DAC ladder is buffered by a rail-to-rail output amplifier. This amplifier is configured as a unity gain follower as shown in Figure 16. The input stage of the amplifier contains a PNP differential pair to provide low offset drift and noise. The output stage is shown in Figure 17. I ...
... The output of the DAC ladder is buffered by a rail-to-rail output amplifier. This amplifier is configured as a unity gain follower as shown in Figure 16. The input stage of the amplifier contains a PNP differential pair to provide low offset drift and noise. The output stage is shown in Figure 17. I ...
36-V, Low-Power, Precision, CMOS, RRIO, Low Offset, Low Input
... – Single in SOIC-8, SOT-5, and VSSOP-8 – Dual in SOIC-8 and VSSOP-8 – Quad in SOIC-14 and TSSOP-14 ...
... – Single in SOIC-8, SOT-5, and VSSOP-8 – Dual in SOIC-8 and VSSOP-8 – Quad in SOIC-14 and TSSOP-14 ...
LTM8048 - 3.1VIN to 32VIN Isolated uModule DC/DC Converter with LDO Post Regulator
... VIN pin, but if the BIAS pin is connected to an external voltage higher than 3.1V, bias power will be drawn from the external source, improving efficiency. VBIAS must not exceed VIN. The RUN pin is used to turn on or off the LTM8048, disconnecting the output and reducing the input current to 1μA or ...
... VIN pin, but if the BIAS pin is connected to an external voltage higher than 3.1V, bias power will be drawn from the external source, improving efficiency. VBIAS must not exceed VIN. The RUN pin is used to turn on or off the LTM8048, disconnecting the output and reducing the input current to 1μA or ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.