![THS4551 Low-Noise, Precision, 150](http://s1.studyres.com/store/data/014839298_1-0b16dd7d12f26bfeb4436b309ccee943-300x300.png)
MAX791 Microprocessor Supervisory Circuit General Description Features
... or debouncing network. It connects to a 1.25V comparator, and has a pull-up to VOUT as shown in Figure 1. The propagation delay from asserting MR to RESET asserted is 4µs typ. Pulsing MR low for a minimum of 15µs resets all the internal counters, sets the Watchdog Output (WDO) and Watchdog-Pulse Out ...
... or debouncing network. It connects to a 1.25V comparator, and has a pull-up to VOUT as shown in Figure 1. The propagation delay from asserting MR to RESET asserted is 4µs typ. Pulsing MR low for a minimum of 15µs resets all the internal counters, sets the Watchdog Output (WDO) and Watchdog-Pulse Out ...
TDA8025HN
... • where β is the accuracy ratio of R1 and R2 (R1 and R2 are considered to be of the ...
... • where β is the accuracy ratio of R1 and R2 (R1 and R2 are considered to be of the ...
Time Delay Relays and Modules - catalog 1308242 issued 3/2003
... Operating life - a measure of the number of operations a TDR can be expected to perform within specifications; for TDRs with electromechanical (EMR) loadswitching means, there are two ratings - mechanical and electrical operations at full rated load. Operating mode - the relationship between control ...
... Operating life - a measure of the number of operations a TDR can be expected to perform within specifications; for TDRs with electromechanical (EMR) loadswitching means, there are two ratings - mechanical and electrical operations at full rated load. Operating mode - the relationship between control ...
12 Introduction to Switched
... the base current drawn from the inverting input in the amplification phase [Fig. 12.5(b)] creates an error in the output voltage. The existence of simple switches and a high input impedance have made CMOS technology the dominant choice for sampled-data applications. The foregoing discussion leads to ...
... the base current drawn from the inverting input in the amplification phase [Fig. 12.5(b)] creates an error in the output voltage. The existence of simple switches and a high input impedance have made CMOS technology the dominant choice for sampled-data applications. The foregoing discussion leads to ...
1 - Monash University Research Repository
... Fi^; ire 8.21: Simulated waveforms for case 1, after compensation with reduced five-level VSI, favg ~ 2kHz - vd: voltage at the end of feeder section. Vjnv: T-PQC inverter switched voltage. Is: feeder substation transformer current. ILB, ILD: various traction load currents. Ijnv: T-PQC inverter curr ...
... Fi^; ire 8.21: Simulated waveforms for case 1, after compensation with reduced five-level VSI, favg ~ 2kHz - vd: voltage at the end of feeder section. Vjnv: T-PQC inverter switched voltage. Is: feeder substation transformer current. ILB, ILD: various traction load currents. Ijnv: T-PQC inverter curr ...
Surge Suppression Catalog
... To ensure 99.999% of service availability and to prolong the service life of mission critical equipment, it is absolutely necessary for facilities to be equipped to effectively dissipate damaging levels of transient surge energy. A complete LIGHTNING PROTECTION SYSTEM includes strike termination dev ...
... To ensure 99.999% of service availability and to prolong the service life of mission critical equipment, it is absolutely necessary for facilities to be equipped to effectively dissipate damaging levels of transient surge energy. A complete LIGHTNING PROTECTION SYSTEM includes strike termination dev ...
datalog 20 – 90 – 140
... Acquisition trigger input in triggered mode ........................................................................ 120 Programmable measurements .............................................................................................. 121 Connections .......................................... ...
... Acquisition trigger input in triggered mode ........................................................................ 120 Programmable measurements .............................................................................................. 121 Connections .......................................... ...
WT1800 Precision Power Analyzer Getting Started Guide User’s
... • The cables are connected firmly to the current input terminals. • There are no problems with the current input terminals and the crimping terminals, such as the presence of foreign substances. During measurement (never touch the terminals and the connected cables when the item under measurement ...
... • The cables are connected firmly to the current input terminals. • There are no problems with the current input terminals and the crimping terminals, such as the presence of foreign substances. During measurement (never touch the terminals and the connected cables when the item under measurement ...
SGA Strain Gauge Load Cell Amplifier / Signal Conditioner Manual
... The module has built-in FILTERS to cancel the field effects of vibration, agitation and electrically noisy environment. The on-board low pass filter can be switched in and adjusted (from 1Hz to 5kHz) using a series of DIP switches. A wide range of proportional output options for currents and voltage ...
... The module has built-in FILTERS to cancel the field effects of vibration, agitation and electrically noisy environment. The on-board low pass filter can be switched in and adjusted (from 1Hz to 5kHz) using a series of DIP switches. A wide range of proportional output options for currents and voltage ...
VS-VSKD600 Series
... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
Area Efficiency Improvement of CMOS Charge Pump Circuits by
... The charge pump is a dc-dc converting circuit used to obtain a dc voltage higher or lower than the supply voltage or opposite in polarity to the supply voltage. Charge pump circuits use capacitors as energy storage devices. The capacitors are switched in such a way that the desired voltage conversio ...
... The charge pump is a dc-dc converting circuit used to obtain a dc voltage higher or lower than the supply voltage or opposite in polarity to the supply voltage. Charge pump circuits use capacitors as energy storage devices. The capacitors are switched in such a way that the desired voltage conversio ...
AD5346 英文数据手册DataSheet 下载
... The GAIN pin on these devices allows the output range to be set at 0 V to VREF or 0 V to 2 × VREF. Input data to the DACs is double-buffered, allowing simultaneous update of multiple DACs in a system using the LDAC pin. An asynchronous CLR input is also provided, which resets the contents of the inp ...
... The GAIN pin on these devices allows the output range to be set at 0 V to VREF or 0 V to 2 × VREF. Input data to the DACs is double-buffered, allowing simultaneous update of multiple DACs in a system using the LDAC pin. An asynchronous CLR input is also provided, which resets the contents of the inp ...
Manual - Curtis Instruments
... The eXm’s DSP runs at 32 MIPS (Million Instructions per Second), allowing the eXm to run six fast PI (Proportional/Integral) closed loop controllers. The eXm’s PI controllers provide an accurate constant current to the load, which is important for precise control of proportional valves. Each output ...
... The eXm’s DSP runs at 32 MIPS (Million Instructions per Second), allowing the eXm to run six fast PI (Proportional/Integral) closed loop controllers. The eXm’s PI controllers provide an accurate constant current to the load, which is important for precise control of proportional valves. Each output ...
Navy Electricity and Electronics Training Series
... many electrical- and electronic-related Navy ratings. Written by, and with the advice of, senior technicians in these ratings, this series provides beginners with fundamental electrical and electronic concepts through self-study. The presentation of this series is not oriented to any specific rating ...
... many electrical- and electronic-related Navy ratings. Written by, and with the advice of, senior technicians in these ratings, this series provides beginners with fundamental electrical and electronic concepts through self-study. The presentation of this series is not oriented to any specific rating ...
586 Capacity of Distribution Feeders for Hosting DER
... should not exceed the installed transformer capacity of the substation at N-1 conditions, possibly taking into account the annual minimum substation load (correction coefficients may apply, further limiting the hosting capacity). In some cases an even stricter criterion is applied, to avoid reverse ...
... should not exceed the installed transformer capacity of the substation at N-1 conditions, possibly taking into account the annual minimum substation load (correction coefficients may apply, further limiting the hosting capacity). In some cases an even stricter criterion is applied, to avoid reverse ...
NTB0101 1. General description Dual supply translating transceiver; auto direction sensing;
... The NTB0101 is a 1-bit, dual supply translating transceiver with auto direction sensing, that enables bidirectional voltage level translation. It features two 1-bit input-output ports (A and B), one output enable input (OE) and two supply pins (VCC(A) and VCC(B)). VCC(A) can be supplied at any volta ...
... The NTB0101 is a 1-bit, dual supply translating transceiver with auto direction sensing, that enables bidirectional voltage level translation. It features two 1-bit input-output ports (A and B), one output enable input (OE) and two supply pins (VCC(A) and VCC(B)). VCC(A) can be supplied at any volta ...
HANDBOOK OF OPERATIONAL AMPLIFIER APPLICATIONS Application Report
... operational amplifier as a comparator – if the output stage is designed to be used that way as in a voltage limiting operational amplifier – or if clamping is added externally that prevents the output from saturating. These applications are shown. ...
... operational amplifier as a comparator – if the output stage is designed to be used that way as in a voltage limiting operational amplifier – or if clamping is added externally that prevents the output from saturating. These applications are shown. ...
Voltage regulator
![](https://commons.wikimedia.org/wiki/Special:FilePath/7812_voltage_regulator.jpg?width=300)
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.