• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Three-Phase Power Quality Analyzer PowerPad™ Model 3945
Three-Phase Power Quality Analyzer PowerPad™ Model 3945

... Three-Phase Power Quality Analyzer PowerPad™ Model 3945 (pdf) ...
G210 STEP MOTOR DRIVE
G210 STEP MOTOR DRIVE

... The power supply voltage must be between 24 VDC and 80 VDC. The maximum power supply current required is 67% of the motor’s rated phase current. An unregulated power supply may be used as long as the voltage stays between the limits; keep the ripple voltage to 10% or less for best results. The drive ...
MODEL ELC-12/20-S and ELC-12/20
MODEL ELC-12/20-S and ELC-12/20

... The terminal-type probe should be attached to the negative (-) battery post near the center of the battery pack. If the threaded stud is long enough above the battery jumper nut, attach the probe with another nut. Torque this nut to proper specifications. If the stud is too short, the nut holding th ...
VOS618A Optocoupler, Phototransistor Output, Low Input Current
VOS618A Optocoupler, Phototransistor Output, Low Input Current

... • High collector emitter voltage, VCEO = 80 V • Isolation test voltage, 3750 VRMS • Low coupling capacitance • High common mode transient immunity ...
Retrofit for Siemens GIS Type 8D1 / 8D2
Retrofit for Siemens GIS Type 8D1 / 8D2

AN-1411 LM3075 Evaluation Board Reference
AN-1411 LM3075 Evaluation Board Reference

... applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask ...
FMS2028 SP6T G A MULTI-BAND GSM ANTENNA
FMS2028 SP6T G A MULTI-BAND GSM ANTENNA

... GaAs devices are fragile and should be handled with great care. Specially designed collets should be used where possible. The back of the die is metallized and the recommended mounting method is by the use of conductive epoxy. Epoxy should be applied to the attachment surface uniformly and sparingly ...
as a PDF - Takeoff Projects
as a PDF - Takeoff Projects

... improved upon this system by introducing a two-loop controller with MPPT. Tao et al., [12] have proposed a multiinput, bidirectional dc–dc converter configuration involving a combination of dc-link and magnetic coupling. The configuration offers high boosting capability and galvanic isolation. Howev ...
Remote AC Power Controller Owner`s Manual
Remote AC Power Controller Owner`s Manual

... Multiple units can be daisy-chained via low-voltage wiring to comprise the building blocks of a versatile, high performance power conditioning and distribution system. A PowerPort system can grow to any size, yet be conveniently switched on and off with either maintained or momentary contact switche ...
Visit us at www.mr
Visit us at www.mr

... normally enough current in your batteries to set fire to your precious Model. Fuses, Diodes, Resistors and Suppression Kits are available on our website at www.mr-rcworld.co.uk ...
To Filter or Divert?
To Filter or Divert?

... the expense of reliability. Novaris uses 275V MOVs for their 240V products to provide adequate headroom for tolerable voltage fluctuations. If lower let through voltages are required Novaris can provide a range of surge filters that offer excellent performance without sacrificing reliability. ...
Medium-Power Plastic NPN Silicon Transistors
Medium-Power Plastic NPN Silicon Transistors

... Buyer is responsible for its products and applications using ON Semiconductor products, including compliance with all laws, regulations and safety requirements or standards, regardless of any support or applications information provided by ON Semiconductor. “Typical” parameters which may be provided ...
MC33340, MC33342 Battery Fast Charge
MC33340, MC33342 Battery Fast Charge

... capacity and operating time while preventing overcharging. Overcharging can result in a reduction of battery life as well as physical harm to the end user. Since most portable applications require the batteries to be charged rapidly, a primary and usually a secondary or redundant charge sensing tech ...
Slide 1
Slide 1

... • The load capacitance voltage is only slowly varying due to the high value of CL . During one conduction period of the rectifier the load voltage can be viewed as a constant voltage source, U 0 , in series with the voltage u AB • The influence of the parallel capacitance, C w, is only significant ...
low harmonic drive packages engineered for you.
low harmonic drive packages engineered for you.

... exclusive roll-out design for ease of installation and servicing helping to reduce installation costs and time. The Allen-Bradley CENTERLINE® Motor Control Center (MCC) 1 8 - Pulse drive package uses a standard Allen-Br a d l e y® 1336 P LUS II design with the front end replaced by a separate 18-Pul ...
Siemens Simatic ST70 Control Systems 2011
Siemens Simatic ST70 Control Systems 2011

COMBINED FIRST AND SECOND SEMESTER B.TECH
COMBINED FIRST AND SECOND SEMESTER B.TECH

... current and produce the main field in the machine. Thus the poles are created electromagnetically. Brush and brush holders Brushes rest on the surface of the commutator. Normally electro-graphite is used as brush material. The actual composition of the brush depends on the peripheral speed of the co ...
MAX848/MAX849 1-Cell to 3-Cell, High-Power, Low-Noise, Step-Up DC-DC Converters General Description
MAX848/MAX849 1-Cell to 3-Cell, High-Power, Low-Noise, Step-Up DC-DC Converters General Description

... The MAX848/MAX849 boost converters set a new standard of high efficiency and high integration for noisesensitive power-supply applications, such as portable phones and small systems with RF data links. The heart of the these devices is a synchronous boost-topology regulator that generates a fixed 3. ...
Power System Reliability: adequacy-long term planning
Power System Reliability: adequacy-long term planning

AP8800 Description Pin Assignments
AP8800 Description Pin Assignments

... L1, the LEDs and the schottky diode D1, and back to the supply rail, but it decays, with the rate of decay determined by the forward voltage drop of the LEDs and the schottky diode. This decaying current produces a falling voltage at RSET, which is sensed by the AP8800. A voltage proportional to the ...
Electron Charge Lab
Electron Charge Lab

operation amplifier circuit templates
operation amplifier circuit templates

FDS6676AS 30V N SyncFET
FDS6676AS 30V N SyncFET

... HEREIN TO IMPROVE RELIABILITY, FUNCTION, OR DESIGN. FAIRCHILD DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS. THESE SPECIFICATIONS DO NOT EXPAND THE T ...
NAS1000X12SXX SMT Non-Isolated Point-of
NAS1000X12SXX SMT Non-Isolated Point-of

... 4). The converter’s pre-bias startup is affected by this function. The converter will still be able to start under a pre-bias condition, but the output voltage waveform will have a glitch during startup. ...
TS0001
TS0001

< 1 ... 811 812 813 814 815 816 817 818 819 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report