• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DM-300 Series Brochure
DM-300 Series Brochure

P84454
P84454

TPS65136 数据资料 dataSheet 下载
TPS65136 数据资料 dataSheet 下载

... the converter topology operates just like any other buck-boost converter topology with the difference that the output voltage across the inductor is the sum of the positive and negative output voltages. With this consideration, all calculations of the buck-boost converter apply for this topology as ...
Model Based-Energy Control of a Solar Power Plant With a
Model Based-Energy Control of a Solar Power Plant With a

... generation applications. The PV array is used as the main generator, and the SC functions as an auxiliary source for supplying the (transient and steady-state) power deficiency of the PV array. For high-power applications, four-phase parallel boost converters and four-phase parallel bidirectional co ...
Design Consideration for Boundary Conduction Mode Power Factor
Design Consideration for Boundary Conduction Mode Power Factor

... to make changes without further notice to any products herein. ON Semiconductor makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ON Semiconductor assume any liability arising out of the application or use of any product or ...
Delphi NC Series Non-Isolated Point of Load DC
Delphi NC Series Non-Isolated Point of Load DC

... is detected. Once the OVP condition is detected, the controller will stop all PWM outputs and will turn on low-side MOSFET driver to prevent any damage to load. ...
Methods of accurately measuring capacitive RH sensors
Methods of accurately measuring capacitive RH sensors

7 – The Power MOSFET 1
7 – The Power MOSFET 1

... The total conduction (on-state) power loss for a given MOSFET with forward current ID and onresistance RDS(on) is given by, The value of RDS(on) can be significant and it varies between tens of milliohms and a few ohms for low-voltage and high-voltage MOSFETS, respectively. The on-state resistance i ...
LM2676 - Texas Instruments
LM2676 - Texas Instruments

2BOhmsLaw - WordPress.com
2BOhmsLaw - WordPress.com

Decibel Reading #1
Decibel Reading #1

... same, but this is seldom the case in practice. For instance, a power amplifier typically has a high INPUT IMPEDANCE and a very low OUTPUT IMPEDANCE for ...
High voltage microfocus CT for inspection of dense, complex parts
High voltage microfocus CT for inspection of dense, complex parts

... A current is applied to the filament, which causes it to heat up and emit electrons. The electrons are repelled by the cathode and attracted to the anode by the high voltage field. This field accelerates the electrons up to 80% of the speed of light toward the end of the tube. Before they leave the ...
Using a Multimeter
Using a Multimeter

... 2. Plug the black and red leads into the meter in the way appropriate for measuring current (black in “COM”, red in “A”). 3. Set the dial on the meter. If you want to measure DC current (like that provided by a battery), use one of the settings in the group marked “DCA”. If you want to measure AC c ...
Aalborg Universitet compensation in an islanded AC microgrid
Aalborg Universitet compensation in an islanded AC microgrid

A high-speed hybrid Full Adder with low power consumption - J
A high-speed hybrid Full Adder with low power consumption - J

... high speed, Full Adder has not a proper PDP (Power-delay product), because it consumes extra average power. Furthermore, a high percentage of the total power consumption of Full Adder is used by generative circuit of carry out, especially in its first inverter. In fact, x-node and y-node which are i ...
Trilogy Linear
Trilogy Linear

... current values. There are many different ways to report these values (for example, peak of sine or RMS of sine) and the results can be very confusing or misleading if the correct formulation is not known. The relationships derived so far use peak of sine (that is, amplitude) values. The equipment ma ...
Electrical Battery Model for Use in Dynamic Electric Vehicle
Electrical Battery Model for Use in Dynamic Electric Vehicle

... Determination of the longest time constant, W hour , and its resistive and capacitive ...
Grant Proposal for Project Name - WSU EECS
Grant Proposal for Project Name - WSU EECS

... to operate at high speed  Power dissipation for those IP blocks could be reduced by operating at a lower voltage  TBB offers the possibility to dynamically operate at either sub-threshold or superthreshold voltages ...
MODEL NRS-12/20 BATTERY CHARGER
MODEL NRS-12/20 BATTERY CHARGER

... order to achieve good charger performance and to prevent damage to the charger and batteries. When a charger is received, a check for possible in-transit damage should be made. If any damage is found, it should be reported as a claim to the carrier. To permit free air flow for convention cooling, al ...
AM26LV31E-EP 数据资料 dataSheet 下载
AM26LV31E-EP 数据资料 dataSheet 下载

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
Breakdown of Gasses - Department of Electrical Engineering
Breakdown of Gasses - Department of Electrical Engineering

... sufficient energy (more than the energy Ei necessary for ionisation to occur), it may ionise by collision. The (mean) number of ionising collisions by one electron per unit drift across the gap is not a constant but subject to statistical fluctuations. The newly liberated electron and the impinging ...
Power Integrations
Power Integrations

DN26
DN26

... becomes unstable and then backing off a fraction. ...
Connection Agreement
Connection Agreement

Soft Starters: the better start in a gentle manner
Soft Starters: the better start in a gentle manner

... fans and pump drives • Controlled start and stop with conveyor drives prevents damage to the transported goods and premature wear in frequently spacious and extensive systems •A  s a three-phase regulator for control of heating and lighting systems as well as for inrush current limitation with tra ...
< 1 ... 767 768 769 770 771 772 773 774 775 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report