• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
RURG3060 30 A, 600 V, Ultrafast Diode Features Description
RURG3060 30 A, 600 V, Ultrafast Diode Features Description

... Counterfeiting of semiconductor parts is a growing problem in the industry. All manufactures of semiconductor products are experiencing counterfeiting of their parts. Customers who inadvertently purchase counterfeit parts experience many problems such as loss of brand reputation, substandard perform ...
EVB USER Guide - Cirel Systems
EVB USER Guide - Cirel Systems

17511 Sample Question Paper
17511 Sample Question Paper

... c) A 3300 V, 50 Hz star connected alternator has a full load current of 90 A. When the output terminals of alternator are shorted a field current of 6 A produces a full load current. The open circuit emf for the same field current was 1000 V. If the armature resistance per phase is 0.5 Ω, find volta ...
Datasheet - Mouser Electronics
Datasheet - Mouser Electronics

... Datasheet contains final specifications. Fairchild Semiconductor reserves the right to make changes at any time without notice to improve the design. ...
BD9A300MUV
BD9A300MUV

... 1ch Synchronous Buck DC/DC Converter BD9A300MUV  Description BD9A300MUV is a synchronous buck switching regulator with built-in low On-resistance power MOSFETs. It is capable of providing current up to 3A. The SLLMTM control provides excellent efficiency characteristics in light-load conditions whi ...
ENGG 3640: Microcomputer Interfacing
ENGG 3640: Microcomputer Interfacing

A Brain-Machine Interface using Dry-Contact, Low
A Brain-Machine Interface using Dry-Contact, Low

... operation is achieved, comparable to current medical-grade systems. Two experiments were described that show robust EEG data collection even in a noisy lab environment. First, alpha waves around 10 Hz were seen to increase in power with closed eyes, which is a commonly reported finding. Second, eye ...
1 - hoytmonitor
1 - hoytmonitor

... Star t: 4:00PM 03/29/11 De tail ...
Development of Fast-Switching SiC Transistor
Development of Fast-Switching SiC Transistor

... Recently, with the growing global interest on energy saving, power device efficiency is becoming increasingly important. Almost all power devices are fabricated utilizing silicon (Si) and their performances have approached to the limit that can be obtained from Si. Silicon carbide (SiC) is one of th ...
A motor control center
A motor control center

... See also: Motor soft starter A small motor can be started by simply plugging it into an electrical receptacle or by using a switch or circuit breaker. A larger motor requires a specialized switching unit called a motor starter or motor contactor. When energized, a direct on line (DOL) starter immed ...
a new static synchronous series compensator for real power control
a new static synchronous series compensator for real power control

Proposal for Battery Facility Technical and Operating Requirements October 22, 2013
Proposal for Battery Facility Technical and Operating Requirements October 22, 2013

... provide fast ramping and fast response services. The potential use of ES resulted in the industry becoming more active in ES integration. In December 2012, the AESO received a System Access Service Request (SASR) for the first ES project in Alberta. In February 2013, another ES project submitted a S ...
File
File

... Like other electrolytics the super capacitor is also polarized so exercise caution in regards to the breakdown voltage. Care must be taken when using this capacitor. It has such large capacitance that, without precautions, it would destroy part of a powersupply such as the bridge rectifier, volt reg ...
PEO-Underpinning-Knowledge-Questions-Power
PEO-Underpinning-Knowledge-Questions-Power

... It is difficult to get hold of the 17th edition book without buying it. However the most important reasons for using the standards and regulations above can be listed as: ...
Inverter - UniMAP Portal
Inverter - UniMAP Portal

... dc-to-ac converters are known as inverters The function of an inverter is to change the dc input voltage to an ac output voltage of desired magnitude and frequency The output voltage waveforms of ideal inverters should be sinusoidal However, the output of practical inverters contains harmonics For h ...
Low Dropout 1 Ampere Linear Regulator Family
Low Dropout 1 Ampere Linear Regulator Family

... with output current, so that dropout at 200mA is less than 100mV. Quiescent current is always less than 650µA. To prevent reverse current conduction, on-chip circuitry limits the minimum forward voltage to typically 50mV. Once the forward voltage limit is reached, the input-output differential volta ...
ASE 112 Electrical Fundamentals
ASE 112 Electrical Fundamentals

specifications
specifications

... 1) AC input voltage is rectified and smoothed by the bridge diode (D901) and capacitors (C912,913). 2) The rectified voltage (DC voltage) is applied to the primary coil of the transformer (T901,T902). 3) The control IC (IC905) generates switching pulse to turn on and off the primary coil of the tran ...
FMA4A
FMA4A

... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
BU2099FV
BU2099FV

... of these parasitic elements can result in mutual interference among circuits, operational faults, or physical damage. Therefore, conditions which cause these parasitic elements to operate, such as applying a voltage to an input pin lower than the ground voltage should be avoided. Furthermore, do not ...
What`s on the board?
What`s on the board?

Single Phase Dual Full Bridge Bi-directional DC
Single Phase Dual Full Bridge Bi-directional DC

... operation of full bridge dc-dc converter. The proposed topology has two single phase full bridge converters on either side of the isolation transformer considering EDLC as energy storage device. Typical applications of this scheme are auxiliary power supply in fuel cell vehicles and battery charging ...
Phase-Locked Loops for Grid-Tied Inverters
Phase-Locked Loops for Grid-Tied Inverters

... matter for a variety grid-connected power electronic converters, be they in the form of distributed power generation systems (DPGS), High Voltage DC transmission (HVDC), Flexible AC Transmission Systems (FACTS) or Custom Power units. Power flow is controlled by adjusting the voltage phase and magnit ...
Technical Conference Publication - Edge
Technical Conference Publication - Edge

... is its ability to convert “waste heat” into electricity which is accomplished by the Thermoelectric Generator (TEG). The selected TEG is capable of outputting up to 5.9W steady state assuming a sufficient temperature differential is present. In the case the thermal output is insufficient; a battery ...
TR41.7-09-11-005-MR1-2564
TR41.7-09-11-005-MR1-2564

... AC power fault testing is conducted with voltages to simulate contact to a mains supply operating at 120/240 V, 120/208 V 3 phase-Y or 277/480 V 3 phase-Y. Testing is also conducted at levels up to 600 Vac for contact or induction faults from higher voltage AC lines, limited by a primary protector. ...
< 1 ... 631 632 633 634 635 636 637 638 639 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report