OIP A 67 dBm Multistacked Junction Varactor 3
... ECENTLY, radio frequency (RF) adaptive systems have drawn a lot of attention, resulting in an intensive search for low-cost low-distortion tunable elements. Potential candidates are semiconductor diodes [1]–[4], MEMS switches/varactors [5], [6] and Barium Strontium Titanate (BST) varactors [7]. Alth ...
... ECENTLY, radio frequency (RF) adaptive systems have drawn a lot of attention, resulting in an intensive search for low-cost low-distortion tunable elements. Potential candidates are semiconductor diodes [1]–[4], MEMS switches/varactors [5], [6] and Barium Strontium Titanate (BST) varactors [7]. Alth ...
Subgap biasing of Superconducting Tunnel Junctions without a Magnetic Field
... STJs offer high spectral resolution, single photon counting, and good quantum efficiency for low-light applications at a variety of wavelengths.1 These detectors operate by counting the number of quasiparticle excitations that are produced when a photon is absorbed. In order to operate, the STJ dete ...
... STJs offer high spectral resolution, single photon counting, and good quantum efficiency for low-light applications at a variety of wavelengths.1 These detectors operate by counting the number of quasiparticle excitations that are produced when a photon is absorbed. In order to operate, the STJ dete ...
Paper - World Academy of Science, Engineering and
... Vision and Local Intelligence has been investigated by [5]; they developed their own controllers with a variety of digital/analog I/O facilities and their own operating system RoBIOS, which allows maximum flexibility. The design of an obstacle avoidance robot has been studied and implemented in [6]- ...
... Vision and Local Intelligence has been investigated by [5]; they developed their own controllers with a variety of digital/analog I/O facilities and their own operating system RoBIOS, which allows maximum flexibility. The design of an obstacle avoidance robot has been studied and implemented in [6]- ...
LTC1069-1 - Low Power, 8th Order Progressive Elliptic, Lowpass Filter
... signal ground can affect the filter performance. For either single or dual supply operation, an analog ground plane surrounding the package is recommended. The analog ground plane should be connected to any digital ground at a single point. For dual supply operation Pin 1 should be connected to the a ...
... signal ground can affect the filter performance. For either single or dual supply operation, an analog ground plane surrounding the package is recommended. The analog ground plane should be connected to any digital ground at a single point. For dual supply operation Pin 1 should be connected to the a ...
MAX1365/MAX1367 Stand-Alone, 4.5-/3.5
... Note 4: Drift error is eliminated by recalibration at the new temperature. Note 5: The input voltage range for the analog inputs is given with respect to the voltage on the negative input of the differential pair. Note 6: VAIN+ or VAIN- = -2.2V to +2.2V. VREF+ or VREF- = -2.2V to +2.2V. All input st ...
... Note 4: Drift error is eliminated by recalibration at the new temperature. Note 5: The input voltage range for the analog inputs is given with respect to the voltage on the negative input of the differential pair. Note 6: VAIN+ or VAIN- = -2.2V to +2.2V. VREF+ or VREF- = -2.2V to +2.2V. All input st ...
Application Note: Turning Varactors
... improved and new ones developed, it became possible to obtain uniformly doped profiles, which resulted in inverse square root dependence. This type is called Abrupt Junction and is presently most commonly used. Hyperabrupt: Many applications require a linear or nearly linear variation of frequency w ...
... improved and new ones developed, it became possible to obtain uniformly doped profiles, which resulted in inverse square root dependence. This type is called Abrupt Junction and is presently most commonly used. Hyperabrupt: Many applications require a linear or nearly linear variation of frequency w ...
Rajasthan Technical University, Kota COURSE - FILE
... 1. Two generators rated 10 MVA, 13.2 KV and 15 MVA, 13.2 KV are connected in parallel to a bus bar. They feed supply to 2 motors of inputs 8 MVA and 12 MVA respectIely. The operating voltage of motors is 12.5 KV. Assuming the base quantities as 50 MVA, 13.8 KV, draw the per unit reactance diagram. T ...
... 1. Two generators rated 10 MVA, 13.2 KV and 15 MVA, 13.2 KV are connected in parallel to a bus bar. They feed supply to 2 motors of inputs 8 MVA and 12 MVA respectIely. The operating voltage of motors is 12.5 KV. Assuming the base quantities as 50 MVA, 13.8 KV, draw the per unit reactance diagram. T ...
Electromagnetic Induction
... This is the action which is responsible for almost all our electricity generation (solar energy being the main exception). If you follow the electric wires in your house back to their source you will find at the other end a generating station which has either a magnet moving in and out of a coil of ...
... This is the action which is responsible for almost all our electricity generation (solar energy being the main exception). If you follow the electric wires in your house back to their source you will find at the other end a generating station which has either a magnet moving in and out of a coil of ...
magnetic field - the SASPhysics.com
... 6.18 explain the use of step-up and step-down transformers in the large scale generation and transmission of electrical energy 6.19 know and use the relationship between input (primary) and output (secondary) voltages and the turns ratio for a transformer: 6.20 know and use the relationship: input p ...
... 6.18 explain the use of step-up and step-down transformers in the large scale generation and transmission of electrical energy 6.19 know and use the relationship between input (primary) and output (secondary) voltages and the turns ratio for a transformer: 6.20 know and use the relationship: input p ...
OKL-T/6-W12 Series
... natural convection unless otherwise indicated. Extended tests at full power must supply substantial forced airflow. All models are tested and specified with external 10μF ceramic output capacitors and a 22 μF external input capacitor. All capacitors are low ESR types. These capacitors are necessary to ...
... natural convection unless otherwise indicated. Extended tests at full power must supply substantial forced airflow. All models are tested and specified with external 10μF ceramic output capacitors and a 22 μF external input capacitor. All capacitors are low ESR types. These capacitors are necessary to ...
User and Installation Manual
... feasibility of electric drive vehicle applications. UQM Technologies, Inc does not imply that these drives have been tested or pass EMI RFI standards as set forth by any of the regulatory agencies. It should be understood that EMI and RFI from UQM Technologies, Inc. drives could interfere with radio ...
... feasibility of electric drive vehicle applications. UQM Technologies, Inc does not imply that these drives have been tested or pass EMI RFI standards as set forth by any of the regulatory agencies. It should be understood that EMI and RFI from UQM Technologies, Inc. drives could interfere with radio ...
ispPAC-POWR1220AT8 Evaluation Board
... Lattice Semiconductor’s Power Manager II ispPAC®-POWR1220AT8 device simplifies power supply design by integrating the analog and digital functions of power supply management (sequencing, monitoring, trimming/margining, measurement) into a single device. This device provides designers with a rich set ...
... Lattice Semiconductor’s Power Manager II ispPAC®-POWR1220AT8 device simplifies power supply design by integrating the analog and digital functions of power supply management (sequencing, monitoring, trimming/margining, measurement) into a single device. This device provides designers with a rich set ...
Comparison of Time-Based Non-Active Power Definitions for Active
... first definitions of non-active power involved rms or average values, and not until more recently did expressions for instantaneous non-active power appear in the literature. Most of the theories have chosen voltage to be a reference and to decompose current into an active component that is responsi ...
... first definitions of non-active power involved rms or average values, and not until more recently did expressions for instantaneous non-active power appear in the literature. Most of the theories have chosen voltage to be a reference and to decompose current into an active component that is responsi ...
RSB6.8CS
... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
Analysis and Design of Switched Capacitor
... used for both the flying capacitor and bypass capacitor. This gives a total ESR contribution of 35 “l. Allowing for 10 &I of trace resistance, total parasitic resistance is 167 mR. The limiting equivalent resistance is 835 d. Capacitor values are specified as *20%, so the design target is 1.05 R equ ...
... used for both the flying capacitor and bypass capacitor. This gives a total ESR contribution of 35 “l. Allowing for 10 &I of trace resistance, total parasitic resistance is 167 mR. The limiting equivalent resistance is 835 d. Capacitor values are specified as *20%, so the design target is 1.05 R equ ...
955 Brik Series Linear Position Sensor
... shield, tied to the coupling nut. To reduce electrical noise, the shield must be properly used. Connect the cable’s shield to the controller system Ground. The cable shield is connected at the connector end. Always observe proper grounding techniques and isolate high voltage (i.e. 120/240VAC) from l ...
... shield, tied to the coupling nut. To reduce electrical noise, the shield must be properly used. Connect the cable’s shield to the controller system Ground. The cable shield is connected at the connector end. Always observe proper grounding techniques and isolate high voltage (i.e. 120/240VAC) from l ...