Automotive Power-Management IC with Three Step-Down Converters and Linear Regulator MAX16920 Features
... The MAX16920 power-management IC integrates three high-voltage step-down DC-DC converters, one high-voltage linear regulator, and an overvoltage protection block. The three step-down converters deliver up to 150mA, 600mA, and 1.5A, while the linear regulator is capable of up to 150mA. The MAX16920 i ...
... The MAX16920 power-management IC integrates three high-voltage step-down DC-DC converters, one high-voltage linear regulator, and an overvoltage protection block. The three step-down converters deliver up to 150mA, 600mA, and 1.5A, while the linear regulator is capable of up to 150mA. The MAX16920 i ...
balanced three–phase circuits
... 11.6 Measuring Average Power in Three-Phase Circuits A wattmeter measures the average power delivered to a load by using a current coil connected in series with the load and a potential coil connected in parallel with the load. : stationary & designed to carry a ct. proportional to the load ct ...
... 11.6 Measuring Average Power in Three-Phase Circuits A wattmeter measures the average power delivered to a load by using a current coil connected in series with the load and a potential coil connected in parallel with the load. : stationary & designed to carry a ct. proportional to the load ct ...
Do-more T1H Series PLC System Specifications
... restrictions with the Do-more T1H Series PLC family. In general, any mix of up to 16 analog and discrete I/O module types can be used in any local or Ethernet I/O base. Specialty modules can also be used in any local or Ethernet I/O base. Reference the Module Placement Restrictions table to the righ ...
... restrictions with the Do-more T1H Series PLC family. In general, any mix of up to 16 analog and discrete I/O module types can be used in any local or Ethernet I/O base. Specialty modules can also be used in any local or Ethernet I/O base. Reference the Module Placement Restrictions table to the righ ...
Saving energy with high-efficiency motors
... a realistic option given how often we fail to turn off the lights in a room even though we can see that they are not needed – something that is certainly not the case when we are dealing with drives used in an industrial application. There are also drives that only have to operate at full power for ...
... a realistic option given how often we fail to turn off the lights in a room even though we can see that they are not needed – something that is certainly not the case when we are dealing with drives used in an industrial application. There are also drives that only have to operate at full power for ...
BDTIC TVS Diodes ESD102-U2-099EL
... Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigation Ltd. EMV™ of EMVCo, LLC (Visa Holdings Inc.). EPCOS™ of Epcos AG. FLEXGO™ of Microsoft Corporation. FlexRay™ is licensed by FlexRay Consortium. HYPERTERMINAL™ of Hilgraeve Incorporated. IEC™ of Commiss ...
... Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigation Ltd. EMV™ of EMVCo, LLC (Visa Holdings Inc.). EPCOS™ of Epcos AG. FLEXGO™ of Microsoft Corporation. FlexRay™ is licensed by FlexRay Consortium. HYPERTERMINAL™ of Hilgraeve Incorporated. IEC™ of Commiss ...
ANN BASED DETECTION OF OS CONDITIONS IN POWER SYSTEM
... having (at least at the first sight) the highest strengths in given task. The accuracy of PDF’s calculation is a non-linear function of the number of simulation runs. Based on some statistics referring to the mean value and variance of distribution (assuming that a PDF is of normal type [4]) it can ...
... having (at least at the first sight) the highest strengths in given task. The accuracy of PDF’s calculation is a non-linear function of the number of simulation runs. Based on some statistics referring to the mean value and variance of distribution (assuming that a PDF is of normal type [4]) it can ...
Catalogue PDF (1,705 KB)
... for each phase. During main busbar connection no gas processing is required. Since the surface of the insulation is earth screened, there is no chance of phase-to-phase short circuits. ...
... for each phase. During main busbar connection no gas processing is required. Since the surface of the insulation is earth screened, there is no chance of phase-to-phase short circuits. ...
CS5124DEMO/D Demonstration Note for CS5124 48 V to 5.0 V,
... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
数字功率钳表使用说明书
... base-wave frequency is between 45 and 65 Hz; harmonic analysis is not performed when base-wave frequency exceeds this range. ...
... base-wave frequency is between 45 and 65 Hz; harmonic analysis is not performed when base-wave frequency exceeds this range. ...
i-STS Model W Product Manual
... The integral maintenance bypass switch should be used when the user is sure that the supplies are both available of the same magnitude and phase. If the STS is on Supply 1 then the maintenance bypass switch should only be operated to position 1. Similarly if the is on Supply 2 then the maintenance b ...
... The integral maintenance bypass switch should be used when the user is sure that the supplies are both available of the same magnitude and phase. If the STS is on Supply 1 then the maintenance bypass switch should only be operated to position 1. Similarly if the is on Supply 2 then the maintenance b ...
BFP650F
... For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expect ...
... For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expect ...
Switches and Circuit Protectors
... Fuse – a device that is designed to open automatically if its current exceeds a specified value ...
... Fuse – a device that is designed to open automatically if its current exceeds a specified value ...
Rad Hard 190K Used Gates 0.5 um CMOS Sea of Gates
... Current Protection this without impacting the functionality of the circuit, three new features have been added: ...
... Current Protection this without impacting the functionality of the circuit, three new features have been added: ...
SIGC39T60E
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
Motion from electricity (The motor effect)
... In 1821 Michael Faraday found a way of producing motion from electricity. He found that if a wire carrying an electric current was placed in a magnetic field then there was a force on the wire; and if it could it moved. This happens because of the combined effects of the magnetic fields of the wire ...
... In 1821 Michael Faraday found a way of producing motion from electricity. He found that if a wire carrying an electric current was placed in a magnetic field then there was a force on the wire; and if it could it moved. This happens because of the combined effects of the magnetic fields of the wire ...
table 7-2 - Newport Scientific
... Never install sensor cable in conduits with or adjacent to AC power or line voltage cables. Induced signals from these lines could cause false readings. Do not adjust the potentiometers on the printed circuit boards. These potentiometers are preset and should be adjusted only by a Newport Scientific ...
... Never install sensor cable in conduits with or adjacent to AC power or line voltage cables. Induced signals from these lines could cause false readings. Do not adjust the potentiometers on the printed circuit boards. These potentiometers are preset and should be adjusted only by a Newport Scientific ...
medium-voltage measuring current transformers user
... Periodically remove any dust or other deposits that may accumulate on the transformers’ surfaces. Avoid using solvents. 8. STAFF TRAINING All installation, commissioning and maintenance operations must be carried out by trained staff. Staff need to be trained in order for them to operate competently ...
... Periodically remove any dust or other deposits that may accumulate on the transformers’ surfaces. Avoid using solvents. 8. STAFF TRAINING All installation, commissioning and maintenance operations must be carried out by trained staff. Staff need to be trained in order for them to operate competently ...
(DEE 411)
... separately excited dc motor for controlling its speed. The firing angle of the converter supplying the field, adjusted such that maximum field current flows. The machine parameters are : armature resistance of 0.25, field circuit resistance of 147, motor voltage constant Kv = 0.7032 V/A-rad/s. Th ...
... separately excited dc motor for controlling its speed. The firing angle of the converter supplying the field, adjusted such that maximum field current flows. The machine parameters are : armature resistance of 0.25, field circuit resistance of 147, motor voltage constant Kv = 0.7032 V/A-rad/s. Th ...