TP2000-AP2300 Modellbasierte Entwicklung innovativer
... In this work package we focus on the possibilities to optimize the energy flow between different electric actuators, which cope with the task of driving, by the use of real-time optimization based control and estimation techniques. The aim is to find a control strategy via model based control which ...
... In this work package we focus on the possibilities to optimize the energy flow between different electric actuators, which cope with the task of driving, by the use of real-time optimization based control and estimation techniques. The aim is to find a control strategy via model based control which ...
Extending the Common-Mode Range of
... VCML = lowest common-mode input voltage [V] Since only one value for R6 can be used, the smaller value must be selected if the common-mode input is bipolar. The total common-mode swing is limited by this value. Reducing the difference amplifier output swing increases the possible common-mode input r ...
... VCML = lowest common-mode input voltage [V] Since only one value for R6 can be used, the smaller value must be selected if the common-mode input is bipolar. The total common-mode swing is limited by this value. Reducing the difference amplifier output swing increases the possible common-mode input r ...
OPA699 Wideband, High Gain VOLTAGE LIMITING AMPLIFIER FEATURES
... (5) CMIR tested as < 3dB degradation from minimum CMRR at specified limits. (6) I VH (VH bias current) is negative, and IVL (VL bias current) is positive, under these conditions. See Note 3 and Figures 2 and 12. (7) Limiter feedthrough is the ratio of the output magnitude to the sinewave added to V ...
... (5) CMIR tested as < 3dB degradation from minimum CMRR at specified limits. (6) I VH (VH bias current) is negative, and IVL (VL bias current) is positive, under these conditions. See Note 3 and Figures 2 and 12. (7) Limiter feedthrough is the ratio of the output magnitude to the sinewave added to V ...
MPC941 rev 10 Final Data Sheet.fm
... The differential LVPECL inputs of the MPC941 allow the device to interface directly with an LVPECL fanout buffer like the MC100EP111 to build very wide clock fanout trees or to couple to a high frequency clock source. The LVCMOS input provides a more standard interface for applications requiring onl ...
... The differential LVPECL inputs of the MPC941 allow the device to interface directly with an LVPECL fanout buffer like the MC100EP111 to build very wide clock fanout trees or to couple to a high frequency clock source. The LVCMOS input provides a more standard interface for applications requiring onl ...
HP 5082-76xx Datasheets
... 1. Device case temperature is 25°C prior to the intensity measurement. 2. The digits are categorized for luminous intensity. The intensity category is designated by a letter on the side of the package. 3. The dominant wavelength, λd, is derived from the CIE chromaticity diagram and is that single wa ...
... 1. Device case temperature is 25°C prior to the intensity measurement. 2. The digits are categorized for luminous intensity. The intensity category is designated by a letter on the side of the package. 3. The dominant wavelength, λd, is derived from the CIE chromaticity diagram and is that single wa ...
Data Sheet (current)
... 1. Device case temperature is 25°C prior to the intensity measurement. 2. The digits are categorized for luminous intensity. The intensity category is designated by a letter on the side of the package. 3. The dominant wavelength, λd, is derived from the CIE chromaticity diagram and is that single wa ...
... 1. Device case temperature is 25°C prior to the intensity measurement. 2. The digits are categorized for luminous intensity. The intensity category is designated by a letter on the side of the package. 3. The dominant wavelength, λd, is derived from the CIE chromaticity diagram and is that single wa ...
AN-1704 LMH6555 Application as High Speed ADC Input Driver
... harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With ...
... harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With ...
Terminations for Advanced CMOS Logic
... of the signal duty cycle. Signals with lower duty cycles will dissipate less DC power. Since the load seen by the driving device is resistive, not capacitive, load capacitance does not affect power consumption. Therefore, parallel termination dissipates less AC power. Because of this lower AC power ...
... of the signal duty cycle. Signals with lower duty cycles will dissipate less DC power. Since the load seen by the driving device is resistive, not capacitive, load capacitance does not affect power consumption. Therefore, parallel termination dissipates less AC power. Because of this lower AC power ...
TNB Technical Guidebook on Grid-interconnection of Photovoltaic
... requirements of PV interconnection with TNB Distribution system. This “Technical Guidebook on Grid-interconnection of Photovoltaic Power Generation System to LV and MV Networks” (“the PV Guidelines”) is intended for use mainly by parties involved in the development and operation of PV generation con ...
... requirements of PV interconnection with TNB Distribution system. This “Technical Guidebook on Grid-interconnection of Photovoltaic Power Generation System to LV and MV Networks” (“the PV Guidelines”) is intended for use mainly by parties involved in the development and operation of PV generation con ...
PS202010EN/ Old G210-90-1
... winding temperature rise rating. The above winding temperature rise shall not exceed 55°C when loaded at base kVA rating. The transformer shall provide an additional 22% continuous operating capacity at the 75°C rating. This transformer is identified as a PEAK transformer. 4 of 13 • October 2015 • S ...
... winding temperature rise rating. The above winding temperature rise shall not exceed 55°C when loaded at base kVA rating. The transformer shall provide an additional 22% continuous operating capacity at the 75°C rating. This transformer is identified as a PEAK transformer. 4 of 13 • October 2015 • S ...
MAX17014 Low-Cost Multiple-Output Power Supply for LCD TVs General Description
... The MAX17014 multiple-output power-supply controller generates all the supply rails for thin-film transistor (TFT) liquid-crystal display (LCD) panels in TVs and monitors operating from a regulated 12V input. It includes a step-down and a step-up regulator, a positive and a negative charge pump, two ...
... The MAX17014 multiple-output power-supply controller generates all the supply rails for thin-film transistor (TFT) liquid-crystal display (LCD) panels in TVs and monitors operating from a regulated 12V input. It includes a step-down and a step-up regulator, a positive and a negative charge pump, two ...
Saturated Load Noise Margin Analysis
... In Fig. S6.1.1, it can be seen that the calculated values of VIH and VIL agree well with SPICE simulation results. Thus, the approximation of neglecting the voltage dependence of the threshold voltage of the load device does not introduce significant error. However, if we so desire, we can use an it ...
... In Fig. S6.1.1, it can be seen that the calculated values of VIH and VIL agree well with SPICE simulation results. Thus, the approximation of neglecting the voltage dependence of the threshold voltage of the load device does not introduce significant error. However, if we so desire, we can use an it ...
PPS3210 Programmable DC Power Supply User`s Manual
... 1. Do not use this instrument in an environment with dusty, vibrating, and corrosive gas and do not explore this machine directly to the sunlight. Please use this instrument in an environment that the ambient temperature is in 0 ~ 40°C and the relative humidity is in 20% ~ 80%. If the temperature is ...
... 1. Do not use this instrument in an environment with dusty, vibrating, and corrosive gas and do not explore this machine directly to the sunlight. Please use this instrument in an environment that the ambient temperature is in 0 ~ 40°C and the relative humidity is in 20% ~ 80%. If the temperature is ...
PS1201C, PS2401C Replacement Power Supply Kits for Electronic
... Cleaners. See Table 1. IMPORTANT These kits cannot be used for air cleaners with performance indicator circuits. ...
... Cleaners. See Table 1. IMPORTANT These kits cannot be used for air cleaners with performance indicator circuits. ...
2ch High Side Switch ICs for USB Devices and Memory Cards Datasheet
... When excessive current flows due to output short-circuit or so, ringing occurs because of inductance between power source lines to IC, and may cause bad influences on IC operations. In order to avoid this case, connect a bypass capacitor across IN terminal and GND terminal of IC. 1μF or higher is re ...
... When excessive current flows due to output short-circuit or so, ringing occurs because of inductance between power source lines to IC, and may cause bad influences on IC operations. In order to avoid this case, connect a bypass capacitor across IN terminal and GND terminal of IC. 1μF or higher is re ...
3.1. The dc transformer model
... converter: transformation of dc voltage and current levels, ideally with 100% efficiency, and control of the conversion ratio M via the duty cycle D. This model can be easily manipulated and solved using familiar techniques of conventional circuit analysis. 2. The model can be refined to account for ...
... converter: transformation of dc voltage and current levels, ideally with 100% efficiency, and control of the conversion ratio M via the duty cycle D. This model can be easily manipulated and solved using familiar techniques of conventional circuit analysis. 2. The model can be refined to account for ...
Reduction of Peak Input Currents during Charge Pump
... electrical energy fed through smart-card contacts or delivered by an on-board RF chip that captures an electromagnetic field in case of contact-less smartcards. It is clear that - especially in the latter case - the available supply current, and to a lesser degree also the supply voltage, is limited ...
... electrical energy fed through smart-card contacts or delivered by an on-board RF chip that captures an electromagnetic field in case of contact-less smartcards. It is clear that - especially in the latter case - the available supply current, and to a lesser degree also the supply voltage, is limited ...
adj5034 - Arecibo Observatory
... The CP581 used for the Arecibo PLC has to be equipped with a Math Coprocessor 80387. An 80387 chip will be installed on each CP581 supplied for this project by Vertex. When purchasing a CP581 directly from Siemens make sure that the 80387 option is included (Siemens Order No. 6ES5 581-0KA11). ...
... The CP581 used for the Arecibo PLC has to be equipped with a Math Coprocessor 80387. An 80387 chip will be installed on each CP581 supplied for this project by Vertex. When purchasing a CP581 directly from Siemens make sure that the 80387 option is included (Siemens Order No. 6ES5 581-0KA11). ...