Practical Simulation and Modelling of Lightning Impulse Voltage
... Standard impulse waveform have similar characteristics as that of lightning strike and can be used for testing the strength of electrical equipment. For producing high voltage pulses Marx generator is the most popular and is most widely used method. This thesis describes the creation of a simulation ...
... Standard impulse waveform have similar characteristics as that of lightning strike and can be used for testing the strength of electrical equipment. For producing high voltage pulses Marx generator is the most popular and is most widely used method. This thesis describes the creation of a simulation ...
MBC15161 User`s Guide
... have holding current at standstill. If the ON/OFF input is low the motor will be turned off with no holding current and clock signals will be ignored. When the ON/OFF input becomes high again, the motor will hold at the step it was in when the ON/OFF input went low. Refer to hook up drawing. ...
... have holding current at standstill. If the ON/OFF input is low the motor will be turned off with no holding current and clock signals will be ignored. When the ON/OFF input becomes high again, the motor will hold at the step it was in when the ON/OFF input went low. Refer to hook up drawing. ...
GS7100A 07/13/06 POWER DELEGATOR SERIES 7100A POWER
... 6.4.1 Each cable assembly shall be factory assembled and tested. 6.4.2 Cable raceways shall be, multi-wall, flexible steel conduit with a plastic waterproof jacket. A copper shielding-grounding conductor must be wound between the steel walls of the flexible conduct. 6.4.3 Conductors in the flexible ...
... 6.4.1 Each cable assembly shall be factory assembled and tested. 6.4.2 Cable raceways shall be, multi-wall, flexible steel conduit with a plastic waterproof jacket. A copper shielding-grounding conductor must be wound between the steel walls of the flexible conduct. 6.4.3 Conductors in the flexible ...
DU-35MV 50/100/200mV DC Full Scale 3 1/2 Digit with 0.56” LEDs
... DU-35CL ..................Process 4 to 20mA (100.0), easily user scalable, 3.5 digit DU-35CLE ......................Process 4 to 20mA (100.0) with 24V DC excitation, scalable, 3.5 digit DU-45CL ..................Process 4 to 20mA (100.00), easily user scalable, 4.5 digit DU-35P...................... ...
... DU-35CL ..................Process 4 to 20mA (100.0), easily user scalable, 3.5 digit DU-35CLE ......................Process 4 to 20mA (100.0) with 24V DC excitation, scalable, 3.5 digit DU-45CL ..................Process 4 to 20mA (100.00), easily user scalable, 4.5 digit DU-35P...................... ...
Evaluates: MAX4200/MAX4201/MAX4202 MAX4201 Evaluation Kit ________________General Description ____________________________Features
... resistors are included for test equipment compatibility. This EV kit can also be used to evaluate the MAX4200 and MAX4202 (contact Maxim for free samples). Note that the MAX4201 has an internal 50Ω output termination resistor, and the MAX4202 has an internal 75Ω output termination resistor, while th ...
... resistors are included for test equipment compatibility. This EV kit can also be used to evaluate the MAX4200 and MAX4202 (contact Maxim for free samples). Note that the MAX4201 has an internal 50Ω output termination resistor, and the MAX4202 has an internal 75Ω output termination resistor, while th ...
BDTIC www.BDTIC.com/infineon S e n s e & ... M A P
... IC based on a capacitive principle. It is surface micromachined with a monolithic integrated signal conditioning circuit implemented in BiCMOS technology. The sensor converts a pressure into an analog output signal. The calibrated transfer function converts a pressure of 10 kPa to 115 kPa into a vol ...
... IC based on a capacitive principle. It is surface micromachined with a monolithic integrated signal conditioning circuit implemented in BiCMOS technology. The sensor converts a pressure into an analog output signal. The calibrated transfer function converts a pressure of 10 kPa to 115 kPa into a vol ...
Document
... The AD8304 is a monolithic logarithmic detector optimized for the measurement of low frequency signal power in fiber optic systems. It uses an advanced translinear technique to provide an exceptionally large dynamic range in a versatile and easily used form. Its wide measurement range and accuracy a ...
... The AD8304 is a monolithic logarithmic detector optimized for the measurement of low frequency signal power in fiber optic systems. It uses an advanced translinear technique to provide an exceptionally large dynamic range in a versatile and easily used form. Its wide measurement range and accuracy a ...
An approach to extract the parameters of solar cells from their
... Many methods used to determine the unknown parameters Iph , Io , a, Rs , and Rsh have been the suggested by various authors [6–23]. Some authors use the measurements of illuminated I − V characteristics at different illumination levels [6–8]. Others utilize dark and illuminated measurements [9–12]. ...
... Many methods used to determine the unknown parameters Iph , Io , a, Rs , and Rsh have been the suggested by various authors [6–23]. Some authors use the measurements of illuminated I − V characteristics at different illumination levels [6–8]. Others utilize dark and illuminated measurements [9–12]. ...
Manual - Martindale Electric
... fault of our manufacturing, with no charge for parts and service. If we are unable to repair or replace the product, we will make a refund of the purchase price. Consult the Instruction Manual for instructions regarding the proper use and servicing of instruments and test equipment. Our obligation u ...
... fault of our manufacturing, with no charge for parts and service. If we are unable to repair or replace the product, we will make a refund of the purchase price. Consult the Instruction Manual for instructions regarding the proper use and servicing of instruments and test equipment. Our obligation u ...
AN162 : Power On Conditions for the X9258
... circuits. If the ramp rate is too slow, the POR occurs when VCC is too low and the wiper data may be recalled incorrectly. If the ramp rate is too fast, the POR circuit responds before the internal circuits have had a chance to “charge up”, again causing a recall when the voltage internal to the dev ...
... circuits. If the ramp rate is too slow, the POR occurs when VCC is too low and the wiper data may be recalled incorrectly. If the ramp rate is too fast, the POR circuit responds before the internal circuits have had a chance to “charge up”, again causing a recall when the voltage internal to the dev ...
1200V Large DIPIPM Version 6 Series Application Note
... may be different from above point. In such cases, it is necessary to change the measuring point to that under the highest power chip. (Refer Section 2.3.2) ...
... may be different from above point. In such cases, it is necessary to change the measuring point to that under the highest power chip. (Refer Section 2.3.2) ...
CHAPTER 4 BIPOLAR JUNCTION TRANSISTORS (BJTs)
... In saturation region, it behaves as a closed switch with a small resistance RCEsat The saturation IV curve can be approximated by a straight line intersecting the vCE axis at VCEoff The saturation voltage VCEsat VCEoff+ICsatRCEsat VCEsat is normally treated as a constant of 0.2 V for simplici ...
... In saturation region, it behaves as a closed switch with a small resistance RCEsat The saturation IV curve can be approximated by a straight line intersecting the vCE axis at VCEoff The saturation voltage VCEsat VCEoff+ICsatRCEsat VCEsat is normally treated as a constant of 0.2 V for simplici ...
Photocontrol Surge Protection 1. ALL ABOUT MOVS 1.1 What is a
... There are three fundamental differences which prove MOV protection to be advantageous: 1) reaction time, 2) clamping voltage, and 3) energy absorption. 1.) MOV surge reaction time is three orders of magnitude faster than that of a spark gap arrestor. MOVs react in nanoseconds, indicated as 10 -9 sec ...
... There are three fundamental differences which prove MOV protection to be advantageous: 1) reaction time, 2) clamping voltage, and 3) energy absorption. 1.) MOV surge reaction time is three orders of magnitude faster than that of a spark gap arrestor. MOVs react in nanoseconds, indicated as 10 -9 sec ...
Recloser Application Notes - Association of Municipal Electricity
... Automatic Circuit Reclosers (ACR) have been around in one form or another for over half a century. Studies of faults on overhead distribution lines have shown that most are transient and can be cleared without interrupting customer supply. This is especially true of areas that experience lightning a ...
... Automatic Circuit Reclosers (ACR) have been around in one form or another for over half a century. Studies of faults on overhead distribution lines have shown that most are transient and can be cleared without interrupting customer supply. This is especially true of areas that experience lightning a ...
All about Digital Input and Digital Output
... There are two ways to approach to the connection types. The first way is to study the connection types and see if there is a type that is necessary for you. If so, then you can refer to the device list in the chapter “Connection Types of ACTi Devices” to make a choice among the cameras that support ...
... There are two ways to approach to the connection types. The first way is to study the connection types and see if there is a type that is necessary for you. If so, then you can refer to the device list in the chapter “Connection Types of ACTi Devices” to make a choice among the cameras that support ...
Introduction to Circuit Analysis
... Use a meter scale with a maximum value higher than the quantity you are measuring. If you do not have a good idea of what the quantity will be, start at the highest scale and work down until you have a good measurement. Some meters have autoscaling, which is a convenient feature that does this autom ...
... Use a meter scale with a maximum value higher than the quantity you are measuring. If you do not have a good idea of what the quantity will be, start at the highest scale and work down until you have a good measurement. Some meters have autoscaling, which is a convenient feature that does this autom ...
EVALUATION AND DESIGN SUPPORT CIRCUIT FUNCTION AND BENEFITS
... final output. Achieving the required output phase matching and settling time can be a challenge, especially at low power levels. The circuit shown in Figure 1 uses the AD8475 differential funnel amplifier to perform attenuation, level shifting, and conversion to differential without the need for any ...
... final output. Achieving the required output phase matching and settling time can be a challenge, especially at low power levels. The circuit shown in Figure 1 uses the AD8475 differential funnel amplifier to perform attenuation, level shifting, and conversion to differential without the need for any ...
ET5X Accessories - Advanced Automation, Inc.
... NOTE: Power Supply (PWRS►Not compatible with devices using 14000-148R) and AC Line Cord Rugged Frame with Rugged I/O port (SG(23844-00-00R) can be used ET5X-8RCSE1-01/SG-ET5X-10RCSE1for demo purposes, but is not ...
... NOTE: Power Supply (PWRS►Not compatible with devices using 14000-148R) and AC Line Cord Rugged Frame with Rugged I/O port (SG(23844-00-00R) can be used ET5X-8RCSE1-01/SG-ET5X-10RCSE1for demo purposes, but is not ...
LM111, LM211, LM311 Differential Comparators
... The LM111, LM211 and LM311 are voltage comparators that have input currents nearly a thousand times lower than legacy standard devices. They are also designed to operate over a wider range of supply voltages: from standard ±15V op amp supplies down to the single 5-V supply used for IC logic. Their o ...
... The LM111, LM211 and LM311 are voltage comparators that have input currents nearly a thousand times lower than legacy standard devices. They are also designed to operate over a wider range of supply voltages: from standard ±15V op amp supplies down to the single 5-V supply used for IC logic. Their o ...