• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CFE Generator Protection Guidelines for Setting 40 and 64G
CFE Generator Protection Guidelines for Setting 40 and 64G

... An ungrounded generator does not have a connection between its neutral and ground. However, it still has phase-toground capacitance because of the generator winding, transformer winding, bus, cable, and auxiliary transformer capacitances. For this type of system, ground faults are limited to very lo ...
PowerLab 30 Series Owner`s Guide
PowerLab 30 Series Owner`s Guide

lecture1423723848
lecture1423723848

... Three phase Transformer: Constructional features of three phase transformers – three phase connection of transformers (Dd0, Dd6, Yy0, Yy6, Dy1, Dy11, Yd1, Yd11, zigzag), Scott connection, open delta connection, three phase to six phase connection, oscillating neutral, tertiary winding, three winding ...
ILD223T - PC Components Company
ILD223T - PC Components Company

... 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as the ...
Analog Pulse Width Modulation
Analog Pulse Width Modulation

... charge from the integration capacitor C3. For this reason, a FET type op amp is recommended because the extremely low bias currents of these amplifiers will not add appreciable error to the triangle wave shape. Finally, the output of the op amp must be able to produce voltages near the supply voltag ...
Practical Analog Design - School of Electrical and Computer
Practical Analog Design - School of Electrical and Computer

Testing Application Notes
Testing Application Notes

... When the CT’s are mounted on the transformer primary windings, the user needs to install jumpers on the secondary windings to eliminate the Turns-Ratio reading errors Typical CT’s on the Delta windings is shown here Secondary windings are shorted (X bushings are shorted) ...
AN1304 Integrated Sensor Simplifies Bar Graph Pressure
AN1304 Integrated Sensor Simplifies Bar Graph Pressure

... is based upon power dissipation in the LM3914 assuming all 10 LED's are lit and ambient temperature is 25°C. The board will survive input transients up to 25 volts provided that power dissipation in the LM3914 does not exceed 1.3 watts. OUT An analog output is supplied at the OUT terminal. The signa ...
LT1970 - 500mA Power Op Amp with Adjustable Precision Current Limit
LT1970 - 500mA Power Op Amp with Adjustable Precision Current Limit

... normally not used and should be left open or shorted to the SENSE– pin. The FILTER pin can be used to adapt the response time of the current sense amplifiers with a 1nF to 100nF capacitor connected to the SENSE – input. An internal 1k resistor sets the filter time constant. SENSE– (Pin 6): Negative Cu ...
HMC-AUH317 数据资料DataSheet下载
HMC-AUH317 数据资料DataSheet下载

... The HMC-AUH317 is a high dynamic range, three stage GaAs HEMT MMIC Medium Power Amplifier which operates between 81 and 86 GHz. The HMCAUH317 provides 22 dB of gain, and an output power of +17.5 dBm at 1 dB compression from a +4V supply voltage. All bond pads and the die backside are Ti/Au metallize ...
Disassembly and Power
Disassembly and Power

... − Good continuity means little or no resistance. − Bad continuity means high or infinite resistance, such as with a broken wire in a cable or a bad fuse. − Continuity checks can also be used to determine which connector pins on one end of a cable are attached to what pins on the other connector end. ...
Phase-shifting Transformer Modeling in PSS®E
Phase-shifting Transformer Modeling in PSS®E

... For short circuit calculations the phase-shifting transformer model for the negative sequence network will employ the same leakage impedance used in the load flow calculations, but the sign of the phase shift angle will be reversed. Hence, if the phase shift angle is +Φ in the positive sequence netw ...
Driving LEDs with a PIC Microcontroller Application Note
Driving LEDs with a PIC Microcontroller Application Note

Benefits of IGBT Technology versus SCR Dimming
Benefits of IGBT Technology versus SCR Dimming

... SCR chokes are tuned to a specific, set rise time at a specific load wattage and load type. And, SCR choke-based systems produce tremendous amounts of heat requiring external, often expensive cooling schemes. This means one IGBT dimming module can adapt its rise time for most efficient operation and ...
INTRODUCTION 1.
INTRODUCTION 1.

... analog and digital [1] . This signal processing refers to multiplication and filtering for the extraction of the information required by an energy meter and includes kWhrs, VARS etc. Typical trends are that companies with newer generation technologies can process most signals in the digital domain w ...
MOC256M AC Input Phototransistor Small Outline Surface Mount Optocouplers
MOC256M AC Input Phototransistor Small Outline Surface Mount Optocouplers

... Fairchild Semiconductor Corporation's Anti-Counterfeiting Policy. Fairchild's Anti-Counterfeiting Policy is also stated on our external website, www.fairchildsemi.com, under Sales Support. Counterfeiting of semiconductor parts is a growing problem in the industry. All manufacturers of semiconductor ...
APPLICATION NOTE - TDA8768A/C2 - 12-BIT HIGH-SPEED A/D CONVERTER DEMONSTRATION BOARD
APPLICATION NOTE - TDA8768A/C2 - 12-BIT HIGH-SPEED A/D CONVERTER DEMONSTRATION BOARD

... This Application Note describes the design and the realization of the Demonstration Board using the TDA8768AH/C2 version (PCB no 834-2) with an application environment. ...
6.0 Electrical Simulations, Field and Iron Material Force Calculations
6.0 Electrical Simulations, Field and Iron Material Force Calculations

... loads that would be impossible to restrain with structures we are contemplating. If these components or other iron components like gas bottles or tools are allowed near the magnet they could easily become disastrous projectiles. If you choose to control the loading via separation, we should consider ...
ELEC 3105 Lecture 17 Real Transformer
ELEC 3105 Lecture 17 Real Transformer

... but there are more of these small currents. So have we really won? The answer is yes, for two reasons. Power loss (the reduction of which is our aim) is proportional to the square of induced voltage. Induced voltage is proportional to the rate of change of flux, and each of our laminations carries o ...
Installation manual - Harrison Hydra-Gen
Installation manual - Harrison Hydra-Gen

... It is best to use a multimeter that can read frequency. You do not want to operate the generator above 63 HZ. Turn on the tool circuit and slowly turn the flow control adjustment screw counter-clockwise to set the frequency. Operate the generator by applying some load to the generator. Using a drill ...
54191/DM54191/DM74191 Synchronous Up/Down 4
54191/DM54191/DM74191 Synchronous Up/Down 4

The Ideal Transformer Description and Circuit Symbol As with all the
The Ideal Transformer Description and Circuit Symbol As with all the

... a transformer with a 1:1 turns ratio is added to a circuit solely to take advantage of the galvanic isolation it offers. What this is good for is best explained with an example. Consider a 50-kW A.M. broadcasting transmitter. The transmitting antenna is a metal tower about 75 m tall, insulated from ...
VFC320 - Texas Instruments
VFC320 - Texas Instruments

... These supplies should be bypassed as close as possible to the converter with 0.01µF capacitors. Internal circuitry causes some current to flow in the common connection (pin 11 on DIP package). Current flowing into the fOUT pin (logic sink current) will also contribute to this current. It is advisabl ...
Protected against direct spray of water from all - Consultations
Protected against direct spray of water from all - Consultations

... (b) is designed so that it can be moved while it is working, or (c) is moved from time to time between the periods during which it is working; “residual current device” means an electro mechanical switching device intended to disconnect a circuit when the residual current attains a stated value unde ...
Design Considerations for Ultracapacitors
Design Considerations for Ultracapacitors

< 1 ... 459 460 461 462 463 464 465 466 467 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report