• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Parallel Charging Using Multiple Controllers With Separate PV Arrays
Parallel Charging Using Multiple Controllers With Separate PV Arrays

EE 1183340
EE 1183340

... and variable frequency). Output of the five leg inverter and Three leg inerter is controlled by SPWM control technique method. It is highly economical, has more Efficiency and fully controllable. Keywords – Five Phase dq Induction Motor, Five phase SPWM Inverter, Three phase dq Induction Motor, Thre ...
Document
Document

... 1. How does the rotor of a dc motor maintain electrical contact with its commutation circuit? By using brushes that are pushed against a spring. 2. Name two motors that do not need brushes for their rotor windings. Squirrel cage induction motor and the brushless DC motor, and some types of stepper m ...
LT1511 - Constant-Current/ Constant-Voltage
LT1511 - Constant-Current/ Constant-Voltage

AN 043 1/9 E521.14 CAN/LIN SBC WITH DC/DC BUCK
AN 043 1/9 E521.14 CAN/LIN SBC WITH DC/DC BUCK

... MDRV (Output which steer the MOS Fet of step-up converter) ...
Generator
Generator

NCP1615 - High Voltage High Efficiency Power
NCP1615 - High Voltage High Efficiency Power

AN2852
AN2852

... The power stage of the PFC comprises inductor L2, MOSFET Q1, diode D4 and capacitor C9. The PFC circuit is quite standard and already well described in previous ST application notes. Therefore this note will focus on the AHB stage and its controller, the L6591. This DCDC converter comprises a half-b ...
PSR-SxF/URM/4X1/2X2
PSR-SxF/URM/4X1/2X2

LT8631 - 100V, 1A Synchronous Micropower
LT8631 - 100V, 1A Synchronous Micropower

... The LT®8631 is a current mode PWM step-down DC/DC converter with internal synchronous switches that provide current for output loads up to 1A. The wide input range of 3V to 100V makes the LT8631 suitable for regulating power from a wide variety of sources, including automotive and industrial systems ...
SGA8543Z HIGH IP , MEDIUM POWER DISCRETE SiGe TRANSISTOR
SGA8543Z HIGH IP , MEDIUM POWER DISCRETE SiGe TRANSISTOR

... Caution! ESD sensitive device. Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional op ...
AND9441 - Current Limits in Electronic Fuses using Direct
AND9441 - Current Limits in Electronic Fuses using Direct

... power MOSFET known as a SENSEFET to control current in the load. All power MOSFETs are made up of thousands of parallel FETs or cells. In a SENSEFET a small percent of the FET cells have their sources separated from the sources of the remaining FET cells. The ratio of cells in the main and small sec ...
CA230008EN/ Old 230-70
CA230008EN/ Old 230-70

FPF2300/02/03 Dual-Output Current Limit Switch
FPF2300/02/03 Dual-Output Current Limit Switch

... arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. Buyer is responsible for its products and applications using ON Semiconductor products, including compliance w ...
Power Consumption at 45nm (WP298)
Power Consumption at 45nm (WP298)

MAX976/MAX978/MAX998 Single/Dual/Quad, SOT23, Single-Supply, High-Speed, Low-Power Comparators ________________General Description
MAX976/MAX978/MAX998 Single/Dual/Quad, SOT23, Single-Supply, High-Speed, Low-Power Comparators ________________General Description

... three-state devices and the small internal current for SHDN, three-stating this pin could also result in indeterminate logic levels. The maximum input voltage for SHDN is 6V, referred to GND, and is not limited by VCC. This allows the use of 5V logic to drive SHDN while VCC operates at a lower volta ...
Did Tesla`s Wardenclyffe tower generate squarewaves?
Did Tesla`s Wardenclyffe tower generate squarewaves?

... coupled? And the coil has very high "Q?" What happens? In that case the coil's RF output voltage will ramp up slowly, as if the oscillating coil was a kind of "capacitor" being charged up. The secondary coil is an energy storage component. But it's being charged up with AC high frequency, not with D ...
Presentation kit - UCSD VLSI CAD Laboratory
Presentation kit - UCSD VLSI CAD Laboratory

Presentation – DC motor
Presentation – DC motor

Standard Start-up P70, P700, P700VC A and P700VC B
Standard Start-up P70, P700, P700VC A and P700VC B

... (Finish setting all the parameters in this document before running the Autotunes) ...
AC Motors
AC Motors

... If we look at a continuous roll of paper, for example, we know that when the roll is stopped it would take a certain amount of force to overcome the inertia of the roll to get it rolling. The force required to overcome this inertia can come from a source of energy such as a motor. Once rolling, the ...
General Description Features
General Description Features

... limit inrush current during startup. An internal stepdown converter current-limit function and a versatile overcurrent shutdown protect the power supplies against fault conditions. The MAX1530/MAX1531 use a currentmode control architecture, providing fast load transient response and easy compensatio ...
RIGOL  User’s Guide DP1308A
RIGOL User’s Guide DP1308A

... Inadequate ventilation may cause increasing of temperature or damages to the device. So please keep well ventilated and inspect the intake and fan regularly. Do Not Operate in Wet Conditions. In order to avoid short circuiting to the interior of the device or electric shock, please do not operate in ...
Aalborg Universitet
Aalborg Universitet

IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

... B. Reducing Switching Activity To reduce power dissipation effectively low power methodologies can be used. Since designers have no influence on Vdd, and switching activity is the remaining one to influence. Methodologies for reducing the switching activity are minimization of glitches and minimizat ...
< 1 ... 398 399 400 401 402 403 404 405 406 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report