• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
to notes16
to notes16

... impedance was given. If the feeder radially feeds a single load at the end of the feeder, this impedance is the actual impedance of the single phase line between the point of regulation and the load. However, if there are multiple taps along the line, then the current at the sending end does not flo ...
Stanford University
Stanford University

... Cooling: (Forced convection) (or) (natural convection) (Provide forced air cooled unit with redundant cooling so that failure of any one cabinet cooling fan or fan circuit will not affect continued operation at full load and ambient temperature of 77 degrees F (25 degrees C) or lower). Operate batte ...
GR-390 GR-392
GR-390 GR-392

... outgoing cable to connect the luminaires to the mains power supply (figure 2). To attach the luminaire to the ceiling pass it s cable from inside the supporting base and then connect the supporting base to the luminaire. This is done by placing the supporting base to the cable s exit and rotating it ...
ML4000 Datasheet - Ototronix Diagnostics
ML4000 Datasheet - Ototronix Diagnostics

... Interactive Diagnostic Audiometric Testing System ...
Driving High Power, High Brightness LEDs
Driving High Power, High Brightness LEDs

... the series is the same throughout the series. Its disadvantage is that if one LED is opened, no LED will light up. The total VF across the series LED is higher, but the current requirement is lower. ...
Chapter 4_Power Transformer
Chapter 4_Power Transformer

... it can deliver at its standard output voltage. This VA rating (KVA or MVA for large power transformers) is dependent on the ambient temperature or cooling provided. Exceeding the VA rating will cause overheating of the core and windings and subsequent damage ...
NEU-4, -6, -8 AND -10 E-BEAM GUN SWITCHING POWER SUPPLY
NEU-4, -6, -8 AND -10 E-BEAM GUN SWITCHING POWER SUPPLY

Conductors and Insulators
Conductors and Insulators

... other ways! The cost of the wiring itself, of course, is obvious, but there are other costs as well. Brainstorm ideas with your students about the cost-inefficiencies of oversized wiring in an electrical system. Notes 9 This question provides an opportunity for ”qualitative” analysis: does the volta ...
Nuclear_Chapter 6
Nuclear_Chapter 6

... an electron. A number of accelerating electrodes called dynodes are arranged in the tube at increasing positive potentials and the electron is accelerated by this electric field towards the first dynode. The incident electron causes multiple secondary electrons to be emitted, which accelerate toward ...
NCP5183 - High Voltage High Current High and Low Side Driver
NCP5183 - High Voltage High Current High and Low Side Driver

Dry-Type Cast Resin, Medium Voltage
Dry-Type Cast Resin, Medium Voltage

... Nameplate shall be [Aluminum][Stainless Steel] A key interlock to prevent unauthorized access shall be provided [Kirk key interlock] [Kirk key interlock with indicating signal light that indicates doors are open] Current transformers shall be provided [details per project documentation] Potential tr ...
GMW360A Sin/Cos to Analog Interpolator IC
GMW360A Sin/Cos to Analog Interpolator IC

... Zero Angle set command - The electrical output of the IC for the zero angle position can be set to match any mechanical position of the magnet within the 360 degree rotation. This feature eliminates the need to mechanically align the position of the sensor output to the mechanical position of the ro ...
Magnetic Latch Solenoid Actuator
Magnetic Latch Solenoid Actuator

... Solenoid Actuator, specially designed for reliable long life service in irrigation systems controlled by Battery Operated Controllers. The BERMAD latching Solenoid Actuator is applicable directly to the valve cover or with a 2-Way Base that enables combining it in variety of 2-way control circuits. ...
Intro to Testing - Electrical and Computer Engineering Department
Intro to Testing - Electrical and Computer Engineering Department

BasicElectronicWorksheet
BasicElectronicWorksheet

... G. Device that is being driven by the source of power; absorbs the power from the supply voltage and converts it to heat, light, etc; resistance connected across a circuit that determines the current flow and energy used H. electrical measuring device (I, E, & R) I. circuit which contains two or mor ...
ECE2262 Electric Circuits Chapter 6: Capacitance and Inductance
ECE2262 Electric Circuits Chapter 6: Capacitance and Inductance

... • A capacitor consists of two conductors separated by a non-conductive region. The non-conductive region (orange) is called the dielectric Charge separation in a parallel-plate capacitor causes an internal electric field. • A dielectric reduces the electric field and increases the capacitance. Beca ...
Top 10 energy saving options
Top 10 energy saving options

... Monitoring and Targeting Systems An effective monitoring and targeting system is typically the most important element of any energy management programme and will deliver the fastest payback. The ability to measure and monitor real time key performance indicators on your site, by collecting the right ...
G Series.indd
G Series.indd

FDFM2N111 Integrated N-Channel PowerTrench MOSFET and Schottky Diode
FDFM2N111 Integrated N-Channel PowerTrench MOSFET and Schottky Diode

... Figure 6. Body Diode Forward Voltage Variation with Source Current and Temperature ...
Sitemte*® Series Brushless Controllers
Sitemte*® Series Brushless Controllers

... Proper overcurrent protection (fusing) is required for the protection of this controller. We recommend a 10 amp , non-time delay fuse. This fuse should be connected in series with the + Input line going to the controller and should be of a value less than or equal to the maximum current rating of th ...
Photovoltaic and thermal solar plants
Photovoltaic and thermal solar plants

... system integrated throughout the grid in a distributed utility structure, like residential home or commercial establishment. Photovoltaic is a simple, low risk technology that can be installed virtually anywhere where sunlight is available. This means that there is a huge potential for the use of ro ...
Fieldbus 502
Fieldbus 502

Volvo XC90 T8 Twin Engine
Volvo XC90 T8 Twin Engine

cPCI200A-1C Series
cPCI200A-1C Series

... Overload response for outputs V1-V3 is constant-current mode. Overload response for V4 is foldback; hiccup mode in response to a hard short. ...
DC – DC CONVERTER 1000W 100 - 400VDC Input / 12VDC Output
DC – DC CONVERTER 1000W 100 - 400VDC Input / 12VDC Output

< 1 ... 1178 1179 1180 1181 1182 1183 1184 1185 1186 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report