5B30 数据手册DataSheet 下载
... stable gain. At the amplifier input, a stable, laser-trimmed zeroscale input voltage is subtracted from the input signal to set the zero scale value. For user convenience, the zero can be optionally factory-set to meet custom needs. This allows suppression of a zero-scale input value many times larg ...
... stable gain. At the amplifier input, a stable, laser-trimmed zeroscale input voltage is subtracted from the input signal to set the zero scale value. For user convenience, the zero can be optionally factory-set to meet custom needs. This allows suppression of a zero-scale input value many times larg ...
2N5401 - CordellAudio.com
... 2. A critical component is any component of a life support which, (a) are intended for surgical implant into the body, device or system whose failure to perform can be or (b) support or sustain life, or (c) whose failure to perform reasonably expected to cause the failure of the life support when pr ...
... 2. A critical component is any component of a life support which, (a) are intended for surgical implant into the body, device or system whose failure to perform can be or (b) support or sustain life, or (c) whose failure to perform reasonably expected to cause the failure of the life support when pr ...
7510 - Analog Modules, Inc.
... since capacitive loading may cause oscillation. If output is connected to a transmission line, proper termination is a must since severe reflections may damage the pre-amp. A series resistor at the output may provide reverse termination and protection with a loss in amplitude. PIN 11 TEMPERATURE SEN ...
... since capacitive loading may cause oscillation. If output is connected to a transmission line, proper termination is a must since severe reflections may damage the pre-amp. A series resistor at the output may provide reverse termination and protection with a loss in amplitude. PIN 11 TEMPERATURE SEN ...
262900 - Low Medium Voltage Motor Controlers
... For motors shut down by the fire alarm system; refer to Division 28 31 00 Fire Alarm Systems. Meet building control systems requirements. ...
... For motors shut down by the fire alarm system; refer to Division 28 31 00 Fire Alarm Systems. Meet building control systems requirements. ...
Specification Sheet
... RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average load factor of 80% for the duration of the power outage. No overload capacity is specified at ...
... RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average load factor of 80% for the duration of the power outage. No overload capacity is specified at ...
Synchronous Machines
... responsible for the production of emf, it is immaterial whether the conductors are rotated or the magnetic flux producing poles are rotated. In most of the alternators it is the field that is rotated rather than the conductors. In an alternator the external connection to the load can be taken direct ...
... responsible for the production of emf, it is immaterial whether the conductors are rotated or the magnetic flux producing poles are rotated. In most of the alternators it is the field that is rotated rather than the conductors. In an alternator the external connection to the load can be taken direct ...
MJD361T4-A
... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
Muhammad Said Abdul Halim
... Mina Maurice William Kindly, according to be out of Egypt, it is from the honor to contact me via: Cell: +254 718 999 887 E-Mail: [email protected] Address ...
... Mina Maurice William Kindly, according to be out of Egypt, it is from the honor to contact me via: Cell: +254 718 999 887 E-Mail: [email protected] Address ...
POWER ELECTRONICS TECHNOLOGY
... fixed DC voltage. The input voltage to rectifier could be either single phase or three phase. AC to DC Converters. An AC to DC converter circuit can convert AC voltage into a DC voltage. The DC output voltage can be controlled by varying the firing angle of the thyristors. The AC input voltage could ...
... fixed DC voltage. The input voltage to rectifier could be either single phase or three phase. AC to DC Converters. An AC to DC converter circuit can convert AC voltage into a DC voltage. The DC output voltage can be controlled by varying the firing angle of the thyristors. The AC input voltage could ...
BC547/BC547A/BC547B/BC547C NPN General Purpose Amplifier
... support device or system whose failure to perform can systems which, (a) are intended for surgical implant into be reasonably expected to cause the failure of the life the body, or (b) support or sustain life, or (c) whose support device or system, or to affect its safety or failure to perform when ...
... support device or system whose failure to perform can systems which, (a) are intended for surgical implant into be reasonably expected to cause the failure of the life the body, or (b) support or sustain life, or (c) whose support device or system, or to affect its safety or failure to perform when ...
IOSR Journal of Applied Physics (IOSR-JAP)
... Abstract: The use of inverters in preference to generators as an alternative for un-interruptible power supply is gaining wide acceptability in developing countries, due to inverters’ greater environmental compatibility. However, the major challenge remains local production of sufficiently high powe ...
... Abstract: The use of inverters in preference to generators as an alternative for un-interruptible power supply is gaining wide acceptability in developing countries, due to inverters’ greater environmental compatibility. However, the major challenge remains local production of sufficiently high powe ...
X4 Drives Specification Sheet
... • Standard Modbus communications • ARCTIC mode for cold locations • V/Hz or Sensorless Vector Control • 3-year warranty ...
... • Standard Modbus communications • ARCTIC mode for cold locations • V/Hz or Sensorless Vector Control • 3-year warranty ...
Product Specifications: AMP-2210S
... The AMP-2210S provides two channels of amplification. Each channel is rated for 210W @ 4Ω or 120W @ 8Ω, and may be bridged together to deliver a robust 420W @ 8Ω to a single load. ENERGY STAR® Qualified Its ultra-efficient design allows the AMP-2210S to meet demanding ENERGY STAR qualification requi ...
... The AMP-2210S provides two channels of amplification. Each channel is rated for 210W @ 4Ω or 120W @ 8Ω, and may be bridged together to deliver a robust 420W @ 8Ω to a single load. ENERGY STAR® Qualified Its ultra-efficient design allows the AMP-2210S to meet demanding ENERGY STAR qualification requi ...
Voltage Fluctuation Impacts (T. McDermott, Sep 2009)
... Voltage Fluctuation Impacts (T. McDermott, Sep 2009) Any type of distributed generation can produce voltage fluctuations on the electric power system. For example, photovoltaic power output can drop from 100% to 20% of nameplate in less than one minute, and wind power output of a single turbine can ...
... Voltage Fluctuation Impacts (T. McDermott, Sep 2009) Any type of distributed generation can produce voltage fluctuations on the electric power system. For example, photovoltaic power output can drop from 100% to 20% of nameplate in less than one minute, and wind power output of a single turbine can ...
Week 10 - Air Washington
... electricity within an electrical apparatus. Its main purpose is to conduct electricity, not to function as a structural member. A distribution point in an aircraft electrical system to which the battery and the generator(s) are connected and from which the electrical loads derive their power. In com ...
... electricity within an electrical apparatus. Its main purpose is to conduct electricity, not to function as a structural member. A distribution point in an aircraft electrical system to which the battery and the generator(s) are connected and from which the electrical loads derive their power. In com ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.