Electronic Circuits
... There are many configurations of capacitors. The three most common are: 1. Fixed – a preset value of capacitance for a specific function. We have disk capacitors to work with in your time constant project. 2. Variable – used in tuning circuits of radios. 3. Electrolytic – Used to filter and/or remov ...
... There are many configurations of capacitors. The three most common are: 1. Fixed – a preset value of capacitance for a specific function. We have disk capacitors to work with in your time constant project. 2. Variable – used in tuning circuits of radios. 3. Electrolytic – Used to filter and/or remov ...
Interconnection Study Report for 10 MW of Wind Generation
... 0.95 and 0.92 for generator and load buses respectively. The company’s preferred upper limit for bus voltage is 1.05 for both generator and load buses. Finally, the instantaneous change in voltage (rise/drop) due to capacitors or generators during system intact conditions is limited to 0.03 PU. Base ...
... 0.95 and 0.92 for generator and load buses respectively. The company’s preferred upper limit for bus voltage is 1.05 for both generator and load buses. Finally, the instantaneous change in voltage (rise/drop) due to capacitors or generators during system intact conditions is limited to 0.03 PU. Base ...
SOiid-State oua1-c1ock Generator
... Note that there are three supply voltages and three ground connections that must be made to the IC. B + to the oscillators must be R-C decoupled to prevent interaction between both circuit halves. The oscillators cannot be gated by applying and removing B + because of a sneak path through from the v ...
... Note that there are three supply voltages and three ground connections that must be made to the IC. B + to the oscillators must be R-C decoupled to prevent interaction between both circuit halves. The oscillators cannot be gated by applying and removing B + because of a sneak path through from the v ...
The desired DC voltage increase from 420 to 600 V is shown in
... Figure 3. Cross section of the 35 kV XLP cable The PSCAD simulation for the service transformer involves a five-limb model. The UMEC (Unified Magnetic Equivalent Circuit) transformer model used in PSCAD is based mostly on core geometry. This allows taking proper account of magnetic coupling between ...
... Figure 3. Cross section of the 35 kV XLP cable The PSCAD simulation for the service transformer involves a five-limb model. The UMEC (Unified Magnetic Equivalent Circuit) transformer model used in PSCAD is based mostly on core geometry. This allows taking proper account of magnetic coupling between ...
Aquarium Lighting and Resource Monitor
... of a users sensor input Organized into different sections with variable time frames Power usage (individual and combined) Temperature (individual and average) pH ...
... of a users sensor input Organized into different sections with variable time frames Power usage (individual and combined) Temperature (individual and average) pH ...
XUPS-600-1000
... voltage regulation with surge protection and noise filtering, and also overvoltage protection with a threshold of 135 vac, and undervoltage protection with a threshold of 95 vac. Upon a brownout, overvoltage, or loss of power, the XUPs will transfer to battery power in less ...
... voltage regulation with surge protection and noise filtering, and also overvoltage protection with a threshold of 135 vac, and undervoltage protection with a threshold of 95 vac. Upon a brownout, overvoltage, or loss of power, the XUPs will transfer to battery power in less ...
1A Step-Down Voltage Regulator
... The LM2575 series offers a high-efficiency replacement for popular three-terminal linear regulators. It substantially reduces the size of the heat sink, and in many cases no heat sink is required. A standard series of inductors optimized for use with the LM2575 are available from several different m ...
... The LM2575 series offers a high-efficiency replacement for popular three-terminal linear regulators. It substantially reduces the size of the heat sink, and in many cases no heat sink is required. A standard series of inductors optimized for use with the LM2575 are available from several different m ...
infresco t
... Short wave infrared lamps are a highly efficient heat source, converting over 90% of consumed electrical power into radiated heat. They offer a very clean and safe form of heating as they generate no fumes plus the design of the lamps ensures a constant level of heat output throughout the lamp life. ...
... Short wave infrared lamps are a highly efficient heat source, converting over 90% of consumed electrical power into radiated heat. They offer a very clean and safe form of heating as they generate no fumes plus the design of the lamps ensures a constant level of heat output throughout the lamp life. ...
Model: HPCW-640 D5-6
... The DSE8610 is an easy to use multi-generator load-share system, designed to synchronise up to 32 generators including electronic and non-electronic engines. The DSE8610 monitors the generator and indicates operational status and fault conditions, automatically starting or stopping the engine on loa ...
... The DSE8610 is an easy to use multi-generator load-share system, designed to synchronise up to 32 generators including electronic and non-electronic engines. The DSE8610 monitors the generator and indicates operational status and fault conditions, automatically starting or stopping the engine on loa ...
UPS (Uninterruptible Power Supplies)
... Input voltage not passed directly to load Rectifies AC to DC (where Storage are connected) then inverts back to AC Seamlessly draws power from DC storage when input voltage lost Independent, conditioned output power Single-phase or three-phase, ratings can exceed 1000 kVA, higher if paralleled ...
... Input voltage not passed directly to load Rectifies AC to DC (where Storage are connected) then inverts back to AC Seamlessly draws power from DC storage when input voltage lost Independent, conditioned output power Single-phase or three-phase, ratings can exceed 1000 kVA, higher if paralleled ...
DN341 - 16-Bit ADC Simplifies Current Measurements
... LT®1029 precision shunt reference. The series resistor should be chosen such that the LT1029 current is at least 1mA at all times. While a conversion is taking place, the LTC2433-1 draws 200µA. During the data output phase, ADC current drops to 4µA and the 6N139 optocoupler draws 2mA at 50% duty cyc ...
... LT®1029 precision shunt reference. The series resistor should be chosen such that the LT1029 current is at least 1mA at all times. While a conversion is taking place, the LTC2433-1 draws 200µA. During the data output phase, ADC current drops to 4µA and the 6N139 optocoupler draws 2mA at 50% duty cyc ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.