• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Three Phase User Manual 4.8 - 16.7 KvA
Three Phase User Manual 4.8 - 16.7 KvA

... digital meter display, and maintenance free sealed lead calcium type batteries. The system components are carefully matched to make the unit a completely self-contained, fully automatic standby power source for operation on all types of lighting loads. The batteries are sized and tested per UL-924 a ...
Presentation Title Here
Presentation Title Here

A/V fiber optical transceiver HOT-3322 | Manual
A/V fiber optical transceiver HOT-3322 | Manual

... To test or generate sync signals the internal pattern generator can be used. The pattern generator can be enabled by holding down the output format set button for three seconds. The pattern generator interface is equal to the selected format selected before the unit enters test pattern mode. If the ...
ALS-102 Core Logic Board Nuclear Automation Background
ALS-102 Core Logic Board Nuclear Automation Background

... integrity, and application-specific data. In the same application, the second EIA-422 communication link can continuously transmit a unidirectional data stream to a qualified display system mounted on the main control board, or to non-safety systems as required by the application. The ALS-102 has a ...
Chapter 25 Alternating Currents
Chapter 25 Alternating Currents

... equilibrium is produced, then a restoring force may cause the object to oscillate until friction damps out the motion. Electric oscillations can be set up in an electrical circuit if analogous conditions are met. Earlier in this chapter it was pointed out that an inductor acts as inertia in impeding ...
Keithley 6517B Electrometer/High Resistance Meter
Keithley 6517B Electrometer/High Resistance Meter

... Simple DMM-like Operation The Model 6517B is designed for easy, DMM-like operation via the front panel, with single-button control of im­por­tant functions such as resistance measurement. It can also be controlled via a built-in IEEE-488 inter­face, which makes it possible to program all func­tions ...
A Modified Control Method For A Dual Unified Power Quality
A Modified Control Method For A Dual Unified Power Quality

Digital Metronome
Digital Metronome

SAE-1100 Series Carbon Monoxide (CO) Detectors
SAE-1100 Series Carbon Monoxide (CO) Detectors

Power semiconductor devices The difference between ideal switch
Power semiconductor devices The difference between ideal switch

... problems of using a SCR for controlling such circuits is that like a diode, the “SCR” is a unidirectional device, meaning that it passes current in one direction only, from Anode to Cathode. Circuits like shown below can be used to obtain full-wave power control in two-directions but this increases ...
3.4 Bipolar Transistor Configurations
3.4 Bipolar Transistor Configurations

... Common-base terminology is derived from the fact that the : base is common to both input and output of t configuration. base is usually the terminal closest to or at ground potential. Majority carriers can cross the reverse-biased junction because the injected majority carriers will appear as minori ...
MEASUREMENT OF MAGNETIC MATERIAL
MEASUREMENT OF MAGNETIC MATERIAL

... All measurements were carried out at the measuring station made by Magnet-physik. The station consists of two devices, which are called RemaCOMP and RemaGRAPH. The first named device is based on measurements using AC excitation (fundamental magnetic characteristics) and second named device is an equ ...
SmartFusion in Clinical Applications Hemodialysis Machine
SmartFusion in Clinical Applications Hemodialysis Machine

... A SmartFusion device can integrate the functions of a hemodialysis engine, typically handled by several discrete components, into a single, reliable, low power programmable device. The functional blocks (shown in green in Figure 1 on page 2) are examples of such integration. ...
unit 3 class
unit 3 class

LT3595EUHH Evaluation Kit Quick Start Guide
LT3595EUHH Evaluation Kit Quick Start Guide

... For higher number of LEDs per string, the LEDs on the board can be removed and a new string can be wired into the anode and cathode connections of the currently-stuffed LEDs. Up to 40V of LEDs can be powered at up to 50mA per string with 45V VIN input to the LT3595. The inductors and capacitors need ...
A Trek 180_Hobart Spec Sheet
A Trek 180_Hobart Spec Sheet

... The integrated charging system is powered by a standard 115 volt household receptacle. The machine can operate while plugged in or completely cordless. The TREK delivers 180 amps (approx. 12% duty cycle) on 115 volt standard power… a weld output which, until TREK, has been limited to 230 volt welder ...
A 36 W Wireless Power Transfer System with 82% Efficiency for LED
A 36 W Wireless Power Transfer System with 82% Efficiency for LED

... sen. Therefore, a transistor with small parasitic capacitance Cds is a better choice to design a high output power Class-E power amplifier.[4] In this study, the transistor IRF640 with less than 200 pF parasitic capacitor Cds was selected when the drain to source voltage is over 30 V. Considering th ...
Sensor Interface
Sensor Interface

... also be monitored continuously. A schematic of the sensor along with a pin-out diagram is shown below to assist in this discussion. ...
monitoring of energy quality for residential consumers
monitoring of energy quality for residential consumers

... which can reach up to rank 50, i.e. 2500 Hz. An indicator that expresses very well the intensity of regime is the distortion factor THD deforming. In figure 3 are shown for a few standard consumers the deformed current curves, the spectrum of current harmonics and distortion factors. According to st ...
Introduction - GEOCITIES.ws
Introduction - GEOCITIES.ws

... The function of the amplifier is to boost the low-level output signal from the piezo-electric receiving transducer up to about 10V pk – pk in order to drive the diode detector that precedes the Schmitt trigger circuit. The relatively high output impedance of the receiver transducer suggests the use ...
RF3928 280W GaN WIDEBAND PULSED POWER AMPLIFIER Features
RF3928 280W GaN WIDEBAND PULSED POWER AMPLIFIER Features

... Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Absolute Maximum Rating conditions is not implied. The information in this publication is believed to be accurate and reliable. However, no responsibility is assum ...
1200V IGBT4 -High Power- Optimized Characteristics for High Current Modules M. Bäßler
1200V IGBT4 -High Power- Optimized Characteristics for High Current Modules M. Bäßler

... High Power comes with a kind of EmCon4 which is also optimized for extreme soft behaviour. Therefore the IGBT can turn on much faster. Taking benefit from the diode softness the turnon losses may be reduced by up to 20%. III. Conclusion: ...
Electric Fields in Material Space The charges considered
Electric Fields in Material Space The charges considered

... current medium is a conductor rather than an insulator. A simple example of conduction current is the current flowing in a conducting wire. If a voltage V is applied to a cylindrical conductor (conductivity = F, length = l, cross-sectional area = A), a conduction current results. ...
B360614
B360614

... power quality conditioner (UPQC), capable of compensating for both the supply voltage and the load current imperfections. A fully digital controller based on the TMS320F2812 DSP platform is implemented for the reference generation as well as control purposes. The delay problem in the digital control ...
RFVC1800 数据资料DataSheet下载
RFVC1800 数据资料DataSheet下载

... Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Absolute Maximum Rating conditions is not implied. RoHS status based on EUDirective2002/95/EC (at time of this document revision). The information in this publicat ...
< 1 ... 559 560 561 562 563 564 565 566 567 ... 838 >

Metadyne



A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report