• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Distributed Generation at Clemson University
Distributed Generation at Clemson University

IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... shunt feedback provided by M2, high low supply requirement close to a transistor threshold voltage VTH , low static power dissipation and high gain bandwidth. The flipped (inverted) voltage follower name is based on the fact that FVF is applied on the drain side than on the side of the source. Varia ...
Design Review David Schlais – Robbie Wankewycz – Jamie Barber
Design Review David Schlais – Robbie Wankewycz – Jamie Barber

P4500S Enclosed System Specifications
P4500S Enclosed System Specifications

... The battery charger is to be certified to UL and CSA specifications, the battery is to be sized in accordance with IEEE and suitable to supply continuous DC power to the control and protection circuits. b) The charger is to be suitable for all types of standby applications and to be capable of suppl ...
Wind Energy Conversion System with Boost Converter and CHB MLI
Wind Energy Conversion System with Boost Converter and CHB MLI

... Research is being carried out in the WECS to meet the energy demand. The advantages of the wind energy are that it is cost effective, pollution free, and safe. It has proven to be the best choice among the renewable energy sources. The developments of the power electronic converters have increased t ...
Design Considerations For Cell Phone Camera Flash Drivers
Design Considerations For Cell Phone Camera Flash Drivers

Power Generation Diesel - Department of Transportation and Works
Power Generation Diesel - Department of Transportation and Works

... Engine: make and model, with performance curves. Alternator: make and model. Voltage regulator: make, model and type. Automatic transfer switch: make, model and type. Manual bypass switch: make and model. Battery: make, type and capacity. Battery charger: make, type and model. Alternator control pan ...
2nd Order Circuits
2nd Order Circuits

... in the circuit before and after a step function transition.  In steady state (t < to and t = ∞s), replace energy storage devices. ...
10 Best Practices for Electrosurgical Unit Testing
10 Best Practices for Electrosurgical Unit Testing

... letting it cool. This is achieved by lower frequency and higher voltage than pure cut. Coagulation is performed by using high voltage and low frequency. In COAG mode, heat is incapable of explosive vaporization, therefore, resulting in a thermal coagulum, also known as a clot. In COAG mode, the surg ...
ANSWERS - AP Physics B final Review Packet Section II: Circuits 1
ANSWERS - AP Physics B final Review Packet Section II: Circuits 1

... current. You can also think of the junction rule where there is 0.04 A going into each junction and 0.04 A leaving to the other battery, with no current for the lower branch. ...
Reactive Power Compensation (Power Factor Correction) AI8 www.edibon.com
Reactive Power Compensation (Power Factor Correction) AI8 www.edibon.com

... MUAD is a continuous data acquisition system with virtual instrumentation, that measures, analyzes and represents the parameters involved in the process. MUAD allows voltage and current acquisition and measurement, data processing, frequency spectrum and all the functions of a digital oscilloscope. ...
PQ_UNIT III
PQ_UNIT III

Individual-phase decoupled P–Q control of three
Individual-phase decoupled P–Q control of three

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

Lecture 1 Power Amplifiers
Lecture 1 Power Amplifiers

... The efficiency obtained in practice is less than the maximum value of other circuit losses and because the peak output voltage must remain less than VCC to avoid transistor saturation which can cause distortion in the output signal. ...
switching frequency effects and efficiency analysis of quadratic buck
switching frequency effects and efficiency analysis of quadratic buck

W13-P-0009
W13-P-0009

... control when subjected to three phase short circuit at the generator bus (worst case). The dynamic simulation is not affected by the wind profile because it can be considered constant during the fault period. Fig. 10 shows the response of stator voltage, current, active power, reactive power and rot ...
Vacuum Tube Power Amps
Vacuum Tube Power Amps

... while measuring the current through V1 and V2. As RV2 is increased, adjust RV1 so the same current is flowing through both tubes. Set the bias so both tubes are drawing 37.5 mA quiescent current. The bias should be periodically checked to compensate for tube aging. This bias point is a compromise be ...
Tramp Iron Removal with actively controlled electromagnets: An
Tramp Iron Removal with actively controlled electromagnets: An

... 100% of the time as is the case with uncontrolled systems, the current can be significantly higher and overall extraction performance is significantly better. c. Control of current ramp-up time. This is only possible with the type of DC drive which Multotec has recently introduced and tested. Conven ...
Slide 1
Slide 1

AN2454
AN2454

... switching frequency must be chosen. To do this, a value of 50 kHz should be selected. It is then necessary to calculate the primary inductance (LP) of the transformer. Using Equation 6, input power (PIN) may be calculated to give an approximate value which does not account for losses due to the powe ...
Audio Power Amplifier
Audio Power Amplifier

... This is the voltage gain for one amplifier on IC ...
Control System Lab
Control System Lab

... 5. Which compensation is adopted for improving transient response of a negative unity feedback system? 6. Which compensation is adopted for improving steady response of a negative unity feedback system? 7. Which compensation is adopted for improving both steady state and transient response of a nega ...
intelligent - SOSManuals
intelligent - SOSManuals

... At normal input voltages the full load rated capacity is available. At input voltages less than 105 VAC the converter may not supply full rated output capacity. The full rated load is available for load, battery charging or both. When functioning as a regulated battery charger, the Kinetik converter ...
Tutorial 3Answer 1. Zener diode has two types of reverse
Tutorial 3Answer 1. Zener diode has two types of reverse

< 1 ... 518 519 520 521 522 523 524 525 526 ... 838 >

Metadyne



A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report