Design of Electronic Control Unit (ECU) for Automobiles
... emissions, together with the need for better performance, fuel economy, continuous diagnosis, Electronic systems form an inevitable part of Engine management. A systems design approach has been used to break down the whole Engine management into three main categories, namely Electronic Charging, Alt ...
... emissions, together with the need for better performance, fuel economy, continuous diagnosis, Electronic systems form an inevitable part of Engine management. A systems design approach has been used to break down the whole Engine management into three main categories, namely Electronic Charging, Alt ...
S285-80-1
... The 24 Vdc control battery is fully charged prior to shipment and is ready for use. The 2.5 amp-hour sealed lead acid jell-cell battery supplies the energy to activate the motors and the control functions. The battery is capable of running a motor for up to 25 open and 25 close operations before rec ...
... The 24 Vdc control battery is fully charged prior to shipment and is ready for use. The 2.5 amp-hour sealed lead acid jell-cell battery supplies the energy to activate the motors and the control functions. The battery is capable of running a motor for up to 25 open and 25 close operations before rec ...
Nexus 1500 Transient Recording Power Quality Revenue Meter Advanced Communication and I/O
... The unit offers an independent out of limit log. This allows a user to download out of limit information to obtain a sequence of events for any occurrence. Utilizing the 10 msec clock resolution, the logs can be combined with different metered points throughout a distribution system to provide an ac ...
... The unit offers an independent out of limit log. This allows a user to download out of limit information to obtain a sequence of events for any occurrence. Utilizing the 10 msec clock resolution, the logs can be combined with different metered points throughout a distribution system to provide an ac ...
ADG752 数据手册DataSheet下载
... The ADG752 is designed on a submicron process that provides low power dissipation yet gives high switching speed and low on resistance. This part is a fully bidirectional switch and can handle signals up to and including the supply rails. Break-before-make switching action ensures the input signals ...
... The ADG752 is designed on a submicron process that provides low power dissipation yet gives high switching speed and low on resistance. This part is a fully bidirectional switch and can handle signals up to and including the supply rails. Break-before-make switching action ensures the input signals ...
Drives - Siemens
... controls, such as internal VFD control boards, cooling fans or pumps, shall be included in all loss calculations. ...
... controls, such as internal VFD control boards, cooling fans or pumps, shall be included in all loss calculations. ...
1. General presentation - OPS Schneider Electric
... foils and several polypropylen films. These elements are connected in series-parallel groups to make the active part of the capacitor. This active part goes in a metallic case which is filled with a dielectric liquid (JARYLEC or SAS 40) (*) and hermetically closed. The metallic case finishing includ ...
... foils and several polypropylen films. These elements are connected in series-parallel groups to make the active part of the capacitor. This active part goes in a metallic case which is filled with a dielectric liquid (JARYLEC or SAS 40) (*) and hermetically closed. The metallic case finishing includ ...
EE1427 ENGINEERING SCIENCE LABORATORY TASKS
... If you examine your control graph you will see that for some intervals there is a need to take additional measurements to fill the gaps between some sets of points, particularly when there are conditions of special interest, such as the value for fc, i.e. the -3dB frequency. Do this while the equipm ...
... If you examine your control graph you will see that for some intervals there is a need to take additional measurements to fill the gaps between some sets of points, particularly when there are conditions of special interest, such as the value for fc, i.e. the -3dB frequency. Do this while the equipm ...
Scaling properties of a non-Fowler–Nordheim tunnelling junction
... with d was observed over a range of several orders of magnitude for d, from millimetres to several nanometres, but it began failing when d was only a few nanometres. At the outset of this work, it must be said that if the emitting surface is either planar or of large radius of curvature R, then the ...
... with d was observed over a range of several orders of magnitude for d, from millimetres to several nanometres, but it began failing when d was only a few nanometres. At the outset of this work, it must be said that if the emitting surface is either planar or of large radius of curvature R, then the ...
BC847BLP4 Features Mechanical Data
... Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically n ...
... Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically n ...
10 - 1 Dave Lawton`s Replication of Stan Meyer`s Water Fuel Cell
... If accuracy of construction is a problem, then it might be possible to give the outer pipes a deliberate slope so that they press against the inner pipes at the top, and then use one short spacer to force them apart and give the desired spacing. It seems clear that Stan worked to such a degree of co ...
... If accuracy of construction is a problem, then it might be possible to give the outer pipes a deliberate slope so that they press against the inner pipes at the top, and then use one short spacer to force them apart and give the desired spacing. It seems clear that Stan worked to such a degree of co ...
Conditions for Running the DTC
... Important: Perform the Circuit/System Verification first. 1. Turn OFF the ignition. 2. Disconnect the ECM C2 harness connector. Important: A high resistance on any IC circuit can cause a misfire condition, before DTCs P0351P0358 set. 3. Disconnect the affected ignition/coil module harness connector. ...
... Important: Perform the Circuit/System Verification first. 1. Turn OFF the ignition. 2. Disconnect the ECM C2 harness connector. Important: A high resistance on any IC circuit can cause a misfire condition, before DTCs P0351P0358 set. 3. Disconnect the affected ignition/coil module harness connector. ...
application aspects
... In the blocking or “off-state”, the preferred gate condition is one of negative bias greater than 2 V. However, any voltage up to the rated gate-cathode value is suitable, while the source impedance should be as low as possible. Under these conditions, the device has virtually no dv/dt limitation, a ...
... In the blocking or “off-state”, the preferred gate condition is one of negative bias greater than 2 V. However, any voltage up to the rated gate-cathode value is suitable, while the source impedance should be as low as possible. Under these conditions, the device has virtually no dv/dt limitation, a ...
development of a basic circuit of a hot-wire anemometer
... kHz, unlike LDA, in which the frequency response is limited to 30 kHz. Some special hot wire anemometers can even operate above a hundred of kHz, accord to Brunn (1971). Low maintenance costs and easy operating are another relevant features making HWA for use in research laboratory the preferred cho ...
... kHz, unlike LDA, in which the frequency response is limited to 30 kHz. Some special hot wire anemometers can even operate above a hundred of kHz, accord to Brunn (1971). Low maintenance costs and easy operating are another relevant features making HWA for use in research laboratory the preferred cho ...
Hd1800
... The red PROTECT LED provides the operator with information about the status of the amplifier. The PROTECT LED can come on under 3 different conditions (when this happens, both channels are muted and the speaker relays disconnect the speakers); 1) During power-up, the amplifier stays in a muted state ...
... The red PROTECT LED provides the operator with information about the status of the amplifier. The PROTECT LED can come on under 3 different conditions (when this happens, both channels are muted and the speaker relays disconnect the speakers); 1) During power-up, the amplifier stays in a muted state ...
BQ4201451457
... This paper deals with a novel type soft switching utility frequency AC- high frequency AC converter using asymmetrical PWM bidirectional active switches which can be defined as high frequency resonant matrix converter.This power frequency changer can directly convert utility frequency AC power to hi ...
... This paper deals with a novel type soft switching utility frequency AC- high frequency AC converter using asymmetrical PWM bidirectional active switches which can be defined as high frequency resonant matrix converter.This power frequency changer can directly convert utility frequency AC power to hi ...
Design of High Voltage Pulse Generator for Pasteurization by
... wave generator will effectively killing S. cerivisiae in apple pasteurization juice if this circuit could produce electric field strength 20 KV/Cm. By using PEF can killing microorganism effectively with out loosing of C vitamin, taste and original aromatic from apple juice pasteurization. This impu ...
... wave generator will effectively killing S. cerivisiae in apple pasteurization juice if this circuit could produce electric field strength 20 KV/Cm. By using PEF can killing microorganism effectively with out loosing of C vitamin, taste and original aromatic from apple juice pasteurization. This impu ...
Compendium of Info on Repairing the Kenwood TS-930S
... needed that long, even in FSK mode. The Kenwood TS-930S owner’s manual warns that output power should be reduced by 50% to prevent PA damage under those conditions. There are two Quint 10-amp models that work well in the 930S. One is the original that PA2VC used, model # 2938604. There’s also a shor ...
... needed that long, even in FSK mode. The Kenwood TS-930S owner’s manual warns that output power should be reduced by 50% to prevent PA damage under those conditions. There are two Quint 10-amp models that work well in the 930S. One is the original that PA2VC used, model # 2938604. There’s also a shor ...
Evaluation Board User Guide UG-192
... applications. The application circuit requires a minimum of external components and operates from a single 2.5 V to 5.5 V supply. It is capable of delivering 3 W of continuous output power with less than 1% THD + N driving a 3 Ω load from a single 5.0 V supply. The SSM2317 is equipped with a differe ...
... applications. The application circuit requires a minimum of external components and operates from a single 2.5 V to 5.5 V supply. It is capable of delivering 3 W of continuous output power with less than 1% THD + N driving a 3 Ω load from a single 5.0 V supply. The SSM2317 is equipped with a differe ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.