document
... as a synchronous DE module with a cycle frequency at most 50Hz. The touch resistance is less than 20 ohm, relatively small compared to the resistance of the two layers, each of which are around 200 ohm typically. C. Analog-to-digital converter A type of successive approximation ADC documented in [7] ...
... as a synchronous DE module with a cycle frequency at most 50Hz. The touch resistance is less than 20 ohm, relatively small compared to the resistance of the two layers, each of which are around 200 ohm typically. C. Analog-to-digital converter A type of successive approximation ADC documented in [7] ...
ME371, MT371 ME372, MT372
... reads Alarm ON status and Alarm OFF status register from the meter) or via GSM/GPRS modem or the RS485 communication interface (“alarm push” at Mx372 – GSM modem constantly reads Alarm ON status and Alarm OFF status register from the meter and, if any alarm is active and enabled, it tries to notify ...
... reads Alarm ON status and Alarm OFF status register from the meter) or via GSM/GPRS modem or the RS485 communication interface (“alarm push” at Mx372 – GSM modem constantly reads Alarm ON status and Alarm OFF status register from the meter and, if any alarm is active and enabled, it tries to notify ...
MAX11131 Evaluation Kit Evaluates: MAX11131 General Description
... 2) Install the EV kit software on your computer by running the INSTALL.EXE program inside the temporary folder. The program files are copied to your PC and icons are created in the Windows Start | Programs menu. During software installation, some versions of Windows may show a warning message indic ...
... 2) Install the EV kit software on your computer by running the INSTALL.EXE program inside the temporary folder. The program files are copied to your PC and icons are created in the Windows Start | Programs menu. During software installation, some versions of Windows may show a warning message indic ...
Five Input Module Users Manual
... The DAQ Series™ Five Input Module is an industrial grade, Ethernet data acquisition module with five optically-isolated, digital inputs. Each input can be used to monitor the state of a digital signal via a web browser, a custom control application, a Programmable Logic Controller (PLC), or an autom ...
... The DAQ Series™ Five Input Module is an industrial grade, Ethernet data acquisition module with five optically-isolated, digital inputs. Each input can be used to monitor the state of a digital signal via a web browser, a custom control application, a Programmable Logic Controller (PLC), or an autom ...
AN00093 TJA1020 LIN transceiver Rev. 02 — 16 September 2005 Application note
... disabled; only a weak current source is present. This minimizes the current consumption in case LIN bus is short-circuited to ground. ...
... disabled; only a weak current source is present. This minimizes the current consumption in case LIN bus is short-circuited to ground. ...
IFS-2600 Install and Programming Manual
... The FIP uses both a liquid crystal display and conventional LED displays for fast and accurate display of system status and changing events. A custom designed membrane keypad is used together with the liquid crystal display and LED indicators to provide fast, efficient and simple modes of operation. ...
... The FIP uses both a liquid crystal display and conventional LED displays for fast and accurate display of system status and changing events. A custom designed membrane keypad is used together with the liquid crystal display and LED indicators to provide fast, efficient and simple modes of operation. ...
Using PowerPoint to Typeset Nice Presentations
... One disadvantage exhibited by the Boost converter: The input current has a “direct path” from the input voltage source to the load. No switch is placed in this path. As a consequence, two problems arise: ...
... One disadvantage exhibited by the Boost converter: The input current has a “direct path” from the input voltage source to the load. No switch is placed in this path. As a consequence, two problems arise: ...
MSAN-108 - Applications of The MT8870 Integrated DTMF Receiver
... Application Note MSAN-108 Applications of The MT8870 Integrated DTMF Receiver ...
... Application Note MSAN-108 Applications of The MT8870 Integrated DTMF Receiver ...
MSAN-108 - Applications of The MT8870 Integrated
... Application Note MSAN-108 Applications of The MT8870 Integrated DTMF Receiver ...
... Application Note MSAN-108 Applications of The MT8870 Integrated DTMF Receiver ...
How to Protect Your House from Lightning
... inadequate to protect most of the equipment in a typical residence. This guide is intended to make more widely known the approaches required to protect modern electrical and electronic equipment in houses. While these surge protection recommendations are broadly applicable, the emphasis will be on s ...
... inadequate to protect most of the equipment in a typical residence. This guide is intended to make more widely known the approaches required to protect modern electrical and electronic equipment in houses. While these surge protection recommendations are broadly applicable, the emphasis will be on s ...
Profile - Honeywell Security
... devices and may supply power to detection devices and transponder(s) or off premises transmitter(s). The control unit may also provide transfer of power to the notification appliances and transfer of condition to relays or devices connected to the control unit. The fire alarm control unit can be a l ...
... devices and may supply power to detection devices and transponder(s) or off premises transmitter(s). The control unit may also provide transfer of power to the notification appliances and transfer of condition to relays or devices connected to the control unit. The fire alarm control unit can be a l ...
1771-2.183, 1771 Analog Input and Output Modules Product Data
... fully isolated differential RTD, fully isolated differential thermocouple/mV, fully isolated differential ...
... fully isolated differential RTD, fully isolated differential thermocouple/mV, fully isolated differential ...
Series CA7 Motor Control Electrical Contactors from Sprecher + Schuh
... The entire CA7 line features mechanically linked contacts, sometimes referred to as “positively guided contacts” or “force guided contacts”. If a main power pole welds, adequate clearances exist (≥0.3mm) to ensure that the auxiliary contacts do not change state when coil power is removed and the dev ...
... The entire CA7 line features mechanically linked contacts, sometimes referred to as “positively guided contacts” or “force guided contacts”. If a main power pole welds, adequate clearances exist (≥0.3mm) to ensure that the auxiliary contacts do not change state when coil power is removed and the dev ...
GLOFA GM6 Series - We Give You Automation Solutions
... circuits such as emergency stop, protective circuits, positioning upper and lower limits switches and interlocking forward/reverse operation. When the PLC detects the following problems, it will stop calculation and turn off all output in the case of watchdog timer error, module interface error, or ...
... circuits such as emergency stop, protective circuits, positioning upper and lower limits switches and interlocking forward/reverse operation. When the PLC detects the following problems, it will stop calculation and turn off all output in the case of watchdog timer error, module interface error, or ...
Bourns® FLAT™ Technology Gas Discharge Tube (GDT) Surge
... GDT DESIGNED WITH BOURNS® FLAT™ TECHNOLOGY Bourns has developed an innovative FLAT™ GDT technology that effectively reduces the size of a GDT while maintaining its isolation and current handling capabilities. The cross section in figure 7 shows the insulating pathway in red. The key design feature o ...
... GDT DESIGNED WITH BOURNS® FLAT™ TECHNOLOGY Bourns has developed an innovative FLAT™ GDT technology that effectively reduces the size of a GDT while maintaining its isolation and current handling capabilities. The cross section in figure 7 shows the insulating pathway in red. The key design feature o ...
AD7730/7730L Data Sheet
... operates from a single +5 V supply. It accepts four unipolar analog input ranges: 0 mV to +10 mV, +20 mV, +40 mV and +80 mV and four bipolar ranges: ± 10 mV, ± 20 mV, ± 40 mV and ± 80 mV. The peak-to-peak resolution achievable directly from the part is 1 in 230,000 counts. An on-chip 6-bit DAC allow ...
... operates from a single +5 V supply. It accepts four unipolar analog input ranges: 0 mV to +10 mV, +20 mV, +40 mV and +80 mV and four bipolar ranges: ± 10 mV, ± 20 mV, ± 40 mV and ± 80 mV. The peak-to-peak resolution achievable directly from the part is 1 in 230,000 counts. An on-chip 6-bit DAC allow ...
VX Wiring and Installation Manual - Vi
... All products manufactured or distributed by Electronz Ltd are subject to the following, and only the following, LIMITED EXPRESS WARRANTIES, and no others. For a period of one (1) year from and after the date of purchase of a new Electronz Ltd product, Electronz Ltd warranties and guarantees only to ...
... All products manufactured or distributed by Electronz Ltd are subject to the following, and only the following, LIMITED EXPRESS WARRANTIES, and no others. For a period of one (1) year from and after the date of purchase of a new Electronz Ltd product, Electronz Ltd warranties and guarantees only to ...
HiAll APPLICATION NOTE
... The information presented in this document should be accurate and reliable. However Sagemcom assumes no responsibility for its use, nor any infringement of patents or other third party rights which may result from its use. This document is subject to change without notice. ...
... The information presented in this document should be accurate and reliable. However Sagemcom assumes no responsibility for its use, nor any infringement of patents or other third party rights which may result from its use. This document is subject to change without notice. ...
A Guide To Diagnostic Insulation Testing Above 1 kV
... The appearance of electronics and the development of battery technology revolutionized the design of insulation testers. Modern instruments are line or battery-powered and produce very stable test voltages under a wide variety of conditions. They are also able to measure very small currents so that ...
... The appearance of electronics and the development of battery technology revolutionized the design of insulation testers. Modern instruments are line or battery-powered and produce very stable test voltages under a wide variety of conditions. They are also able to measure very small currents so that ...
Full Power Balanced Power Amplifiers Instructions for Use
... A proprietary Krell circuit technologyfor connecting analog components,in which the audio waveformis transmitted between components in the current rather than voltage domain.The speed and bandwidth provided by Krell CAST yields accurate, realistic music reproduction. Krell componentsconnected via CA ...
... A proprietary Krell circuit technologyfor connecting analog components,in which the audio waveformis transmitted between components in the current rather than voltage domain.The speed and bandwidth provided by Krell CAST yields accurate, realistic music reproduction. Krell componentsconnected via CA ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.