• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Very Low Power, Negative Rail Input, Rail-to
Very Low Power, Negative Rail Input, Rail-to

... DESCRIPTION The THS4524 is a very low-power, fully differential operational amplifier with rail-to-rail output and an input common-mode range that includes the negative rail. This amplifier is designed for low-power data acquisition systems and high-density applications where power dissipation is a ...
User Manual for theHE693SER300- Sequence of Events Recorder
User Manual for theHE693SER300- Sequence of Events Recorder

... RS-485 port on the power supply of the Series 90-30 rack that contains the SER300. An HE693SNP232 (RS-485 to RS232 adapter) is needed for this connection. With the cable connected and the SER300 powered up, press 2 to select “Configure the module”. The following screen will appear: ...
AD7892 LC MOS Single Supply, 12
AD7892 LC MOS Single Supply, 12

... that operates from a single +5 V supply. The part contains a 1.47 µs successive approximation ADC, an on-chip track/hold amplifier, an internal +2.5 V reference and on-chip versatile interface structures that allow both serial and parallel connection to a microprocessor. The part accepts an analog i ...
sealed lead-acid batteries
sealed lead-acid batteries

... To produce a truly maintenance-free battery, it is necessary that gases generated during overcharge are recombined in a so-called “oxygen cycle”. Should oxygen and hydrogen escape, a gradual drying out would occur, eventually affecting capacity and battery life. During charge, oxygen is generated at ...
The Use of Low-Voltage Current-Limiting Fuses to Reduce Arc-Flash Energy Kenneth Borgwald
The Use of Low-Voltage Current-Limiting Fuses to Reduce Arc-Flash Energy Kenneth Borgwald

10-12-04 Air Conditioner Bulletin A27
10-12-04 Air Conditioner Bulletin A27

... Check for voltage between the BLACK (GND terminal on thermostat) (Unlabeled) wire and: • Orange wire for voltage ranging from 8.38 to 17.31 VDC. Fan terminal on thermostat. • Blue wire for voltage ranging from 8.38 to 17.31 VDC. High fan terminal on thermostat. • White wire for voltage ranging from ...
Calculating Power Losses in an IGBT Module
Calculating Power Losses in an IGBT Module

... the conduction losses with an estimated factor to take into account switching losses, might result in large errors concerning the total losses switching losses occurred because the transitions from on-state to off-state and vice versa do not occur instantaneously. During the transition interval both ...
Digital-Multimeter M 3860-M Order No.: 12 39 00 Attention!
Digital-Multimeter M 3860-M Order No.: 12 39 00 Attention!

... • If covers are opened or parts are removed, except it is possible without tools, voltage-carrying components may be accessable. Terminals can also carry voltage. If it is necessary to open the unit before adjustment, maintenance, repairing or exchange of parts or modules, the measuring unit has to ...
Introduction - Electrical and Computer Engineering
Introduction - Electrical and Computer Engineering

...  Second term is TRANSIENT RESPONSE ELEC 308 ...
SIP 05167 Ideal 304 Welder Manual
SIP 05167 Ideal 304 Welder Manual

... optioned duty cycle). Make sure that the welding current should not exceed the max load current. Over-load current could obviously shorten the welding equipment's life, or even burn the equipment. 2.3 Over-voltage is forbid. Regarding the power supply voltage range of the welding machine, please ref ...
FDMF6706C – Extra-Small, High-Performance, High- Frequency DrMOS Module FD MF6706C
FDMF6706C – Extra-Small, High-Performance, High- Frequency DrMOS Module FD MF6706C

... the high-side and the low-side MOSFETs. Each part is capable of driving speeds up to 1 MHz. ...
Microelectromechanical Devices
Microelectromechanical Devices

... line currents are also balanced. The individual line current components can be obtained from the Fourier series of the line voltage. The total current can be obtained by addition of the individual currents. A typical line current wave with inductive load is shown below. ...
here - Integrated Consultants, Inc.
here - Integrated Consultants, Inc.

... battery 32 across voltage divider R1, R2. The battery may be a 12 VDC battery in one embodiment, with the midpoint of voltage divider R1, R2 referenced at 5VDC when full and proportional to the battery charge. This reference voltage passes through D1 to the gate of Q1 which applies the full battery ...
Design of CMOS Comparators for FLASH ADC
Design of CMOS Comparators for FLASH ADC

rail mounted power network meter n43 n43 type user`s manual
rail mounted power network meter n43 n43 type user`s manual

... Entry into monitoring of maximum and minimum values mode occurs when pressing at the same time the buttons and for at least 3 seconds. Erasing maximum and minimum values is done by pressing the button while monitoring their value.Alarms are active if they were allocated. Note that the alarms do not ...
MOS Amplifier Topologies
MOS Amplifier Topologies

...  With the input connected to different locations, the two circuits, although identical in other aspects, behave differently. CH7 CMOS Amplifiers ...
Characteristics and performance of 10 kW class all
Characteristics and performance of 10 kW class all

... et al., which produced an average power output of 1.1 kW at the discharge current density of 60 mA cm−2 with an energy efficiency of 77.7% [5]. Different kinds of RFBs have been studied at our research group since 1989 [3,17–26]. In this work, we focused on the characteristics and performance of the ...
MAX14550E Evaluation Kit Evaluates: General Description Features
MAX14550E Evaluation Kit Evaluates: General Description Features

a new static synchronous series compensator for real power control
a new static synchronous series compensator for real power control

Subthreshold Logical Effort: A Systematic Framework for Optimal
Subthreshold Logical Effort: A Systematic Framework for Optimal

... According to these results, we expect to achieve a higher drivecurrent through the two-transistor stack when the lower device is larger than the upper transistor by a factor of α . For example, with a WU of 1µm the optimal WL is 1.189µm at Vdd = 0.3V, and 1.122µm at Vdd = 0.2V. As shown in equation ...
ML******MPPT** - Solar charge controller
ML******MPPT** - Solar charge controller

ML Maximum Power Point Tracking (MPPT) Series Solar
ML Maximum Power Point Tracking (MPPT) Series Solar

... continuously lock onto this point to charge the battery, conventional controllers (employing switching and PWM charging technologies) can't get the most of the power from the solar panel. But a solar charge controller featuring MPPT technology can continuously track arrays' maximum power point so as ...
Diagnostics - Mech-Line
Diagnostics - Mech-Line

... The drive detects error situations and reports them using: • The green and red LED on the body of the drive • The status LED on the control panel (if the HVAC control panel is attached to the drive) • The control panel display (if the HVAC control panel is attached to the drive) • The Fault Word and ...
New Breed of Network Fault-Tolerant Voltage-Source
New Breed of Network Fault-Tolerant Voltage-Source

... per converter with the proposed HVDC system is one quarter of those required for a system based on the modular multilevel converter. With a large number of cells per phase, the voltage waveform generated across the H-bridge cells is as shown in Fig. 1, and an effective switching frequency per device ...
Table of Contents 8.0
Table of Contents 8.0

... © 2007 UniStar Nuclear Development, LLC. All rights reserved. COPYRIGHT PROTECTED ...
< 1 ... 144 145 146 147 148 149 150 151 152 ... 838 >

Metadyne



A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.