REF1004-1.2 数据资料 dataSheet 下载
... The REF1004-1.2 and REF1004-2.5 are two terminal bandgap reference diodes designed for high accuracy with outstanding temperature characteristics at low operating currents. Prior to the introduction of the REF1004 Micropower Voltage References, accuracy and stability specifications could only be att ...
... The REF1004-1.2 and REF1004-2.5 are two terminal bandgap reference diodes designed for high accuracy with outstanding temperature characteristics at low operating currents. Prior to the introduction of the REF1004 Micropower Voltage References, accuracy and stability specifications could only be att ...
Harmonic Presentation
... order harmonics. Has little effect on the 5th and 7th harmonics. Because of the associated voltage drop, there are limits to the amount of reactance that may be added. ...
... order harmonics. Has little effect on the 5th and 7th harmonics. Because of the associated voltage drop, there are limits to the amount of reactance that may be added. ...
... Since the switching behavior of a DMOS is strongly nonlinear, the accurate description of MOS Capacitances, is essential (Miller Capacitance) for realistic results like EMI analysis. DC- characteristics as Rdson depend not only of the intrinsic MOS Channel, but might also be dominated by drift regio ...
A+ Guide to Managing and Maintaining your PC, 6e
... Joules rating that is greater than 600 joules Protection activated in less than 2 nanoseconds Warranty for connected equipment and UL seal Light indicating that surge protection is working Data line protector for telephone line to modem Let-through voltage rating and line noise filtering ...
... Joules rating that is greater than 600 joules Protection activated in less than 2 nanoseconds Warranty for connected equipment and UL seal Light indicating that surge protection is working Data line protector for telephone line to modem Let-through voltage rating and line noise filtering ...
draft sensor loading analysis - Acta Universitatis Agriculturae et
... transformed to the electrical signal. Due to realized measurements function and behavior of dra sensor while loading by draught force was cleared. Result of this measurement is that the dra sensor measures spatial tension and transmits it to the electrohydraulic system control unit in a form of vo ...
... transformed to the electrical signal. Due to realized measurements function and behavior of dra sensor while loading by draught force was cleared. Result of this measurement is that the dra sensor measures spatial tension and transmits it to the electrohydraulic system control unit in a form of vo ...
BP104
... 3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C (transitional substances) respectively. Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting substances and do not contain such substances. ...
... 3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C (transitional substances) respectively. Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting substances and do not contain such substances. ...
Evaluates: MAX8537 MAX8537 Evaluation Kit General Description Features
... Output Enables (EN1 and EN2) Outputs of the MAX8537 can be turned on and off independently at EN1 and EN2. Jumper JU3, position 1-2, pulls EN2 high to turn on VOUT2; position 2-3 pulls EN2 low to turn off VOUT2. Jumper JU4, position 1-2, pulls EN1 high to turn on VOUT1; position 2-3 pulls EN1 low to ...
... Output Enables (EN1 and EN2) Outputs of the MAX8537 can be turned on and off independently at EN1 and EN2. Jumper JU3, position 1-2, pulls EN2 high to turn on VOUT2; position 2-3 pulls EN2 low to turn off VOUT2. Jumper JU4, position 1-2, pulls EN1 high to turn on VOUT1; position 2-3 pulls EN1 low to ...
ATU900 - Water Solutions
... Mounted on the lid is the display board. The LCD and LEDs are fitted on the reverse side, facing upwards towards the user. This board also contains the secondary power module, and may house a further ten ‘D’ cell battery holders in battery powered units, allowing up to twenty batteries in total to b ...
... Mounted on the lid is the display board. The LCD and LEDs are fitted on the reverse side, facing upwards towards the user. This board also contains the secondary power module, and may house a further ten ‘D’ cell battery holders in battery powered units, allowing up to twenty batteries in total to b ...
TSA7887 - Silicon Labs
... and draws 0.85mA supply current. The wideband input track-and-hold acquires signals in 500ns and features a single-ended sampling topology. Output data coding is straight binary and the ADC is capable of converting full power signals up to 2.5 MHz. The ADC also contains an integrated 2.5V reference ...
... and draws 0.85mA supply current. The wideband input track-and-hold acquires signals in 500ns and features a single-ended sampling topology. Output data coding is straight binary and the ADC is capable of converting full power signals up to 2.5 MHz. The ADC also contains an integrated 2.5V reference ...
S320-42-1
... the FCI has sensed a fault, the dry contacts will latch closed until the FCI is reset manually or until normal system power is restored, following the fault. If the FCI has been reset, the dry contacts will latch in the open position. A simple control diagram of the contacts is shown in Figure 7. Wh ...
... the FCI has sensed a fault, the dry contacts will latch closed until the FCI is reset manually or until normal system power is restored, following the fault. If the FCI has been reset, the dry contacts will latch in the open position. A simple control diagram of the contacts is shown in Figure 7. Wh ...
TSUS5402
... statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or ...
... statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or ...
IB1011S190 - Integra Technologies, Inc.
... conditions above those given in the characteristics sections of the specification is not implied. Exposure to maximum values for extended periods of time may affect device reliability. ...
... conditions above those given in the characteristics sections of the specification is not implied. Exposure to maximum values for extended periods of time may affect device reliability. ...
Induction Motor and Faults
... Two sets of bearings are placed at both the ends of the rotor of an induction motor to support the rotating shaft. They held the rotor in place and help it to rotate freely by decreasing the frictions. Each bearing consists of an inner and an outer ring called races and a set of rolling elements cal ...
... Two sets of bearings are placed at both the ends of the rotor of an induction motor to support the rotating shaft. They held the rotor in place and help it to rotate freely by decreasing the frictions. Each bearing consists of an inner and an outer ring called races and a set of rolling elements cal ...
AN2834 Application note How to get the best ADC accuracy in STM32F10xxx devices
... the analog reference will cause a change in the converted digital value. For example, with an analog reference of 3.3 V and a 1 V signal input, the converted result is (1/3.3) × 4095 = 4D9h But with a 40 mV peak-to-peak ripple in the power supply, the converted value becomes (1/3.34) × 4095 = 4CAh ( ...
... the analog reference will cause a change in the converted digital value. For example, with an analog reference of 3.3 V and a 1 V signal input, the converted result is (1/3.3) × 4095 = 4D9h But with a 40 mV peak-to-peak ripple in the power supply, the converted value becomes (1/3.34) × 4095 = 4CAh ( ...
E.M.I Effects of Cathodic Protection on Electromagnetic Flowmeters
... electromagnetic interference (EMI) can distort the magnetic field of the electromagnetic flowmeter. If specific precautions; such as installing an electromagnetic flowmeter in pipelines with cathodic protection are not taken, measurements will be wrong. Figure 5 shows the electrically insulated test ...
... electromagnetic interference (EMI) can distort the magnetic field of the electromagnetic flowmeter. If specific precautions; such as installing an electromagnetic flowmeter in pipelines with cathodic protection are not taken, measurements will be wrong. Figure 5 shows the electrically insulated test ...
MN201001EN/S201-20-1
... Eaton's Cooper Power series single-phase pad-mounted distribution transformers. Pad-mounted distribution transformers from Eaton's Cooper Power series are designed for installation on single-phase underground systems. All units are constructed for weather exposed mounting on a concrete pad with high ...
... Eaton's Cooper Power series single-phase pad-mounted distribution transformers. Pad-mounted distribution transformers from Eaton's Cooper Power series are designed for installation on single-phase underground systems. All units are constructed for weather exposed mounting on a concrete pad with high ...
LEVEL MONITOR D A TA SHEET F173 - LEVEL MONITOR
... The F173 is a versatile level indicator with linearization and continuous level monitoring feature. It offers the facility to set two low level and two high level alarm values. If desired, an ignore function can be set up to allow for an incorrect level for a certain period of time. Up to four outpu ...
... The F173 is a versatile level indicator with linearization and continuous level monitoring feature. It offers the facility to set two low level and two high level alarm values. If desired, an ignore function can be set up to allow for an incorrect level for a certain period of time. Up to four outpu ...
Developing a 1296 MHz Beacon - Mini-Kits
... If the supply volts change, then this changes operating points of unregulated stages, which changes the load on the oscillator, which can cause frequency shifts. Supply Volts changing can also result in output level variation. Improved crystal heater Crystal with no temperature control shows ~ 3 kHz ...
... If the supply volts change, then this changes operating points of unregulated stages, which changes the load on the oscillator, which can cause frequency shifts. Supply Volts changing can also result in output level variation. Improved crystal heater Crystal with no temperature control shows ~ 3 kHz ...
BU21023GUL
... Please pull up the ECL, EDA, and INT pins using 10k ohm resistors as shown in the application diagram at the end of this document. ECL and EDA pins may be directly connected to GND if an external EEPROM is not being used. Please connect a 0.1µF capacitor between T4 and GND. T1, T2 & T3 pins should b ...
... Please pull up the ECL, EDA, and INT pins using 10k ohm resistors as shown in the application diagram at the end of this document. ECL and EDA pins may be directly connected to GND if an external EEPROM is not being used. Please connect a 0.1µF capacitor between T4 and GND. T1, T2 & T3 pins should b ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.