CdZnTe Semiconductor Detectors for Spectroscopic X
... other geometrical arrangement as required by the CdZnTe detector array and interface substrate configuration. The pin probe array is mounted on an interface circuit board with connectors to connect to the front-end readout electronics boards (FE-ASIC boards). Fig. 8 shows the schematic arrangement o ...
... other geometrical arrangement as required by the CdZnTe detector array and interface substrate configuration. The pin probe array is mounted on an interface circuit board with connectors to connect to the front-end readout electronics boards (FE-ASIC boards). Fig. 8 shows the schematic arrangement o ...
General Description Features
... The EV kit if fully assembled and tested. Follow the steps below to verify board operation: 1) Verify that shunts are installed on pins 1-2 on jumpers JU1 and JU2. 2) Verify that a shunt is installed on jumper JU3. 3) Connect the USB cable to the USB connector (P1) on the EV kit. 4) Connect the ...
... The EV kit if fully assembled and tested. Follow the steps below to verify board operation: 1) Verify that shunts are installed on pins 1-2 on jumpers JU1 and JU2. 2) Verify that a shunt is installed on jumper JU3. 3) Connect the USB cable to the USB connector (P1) on the EV kit. 4) Connect the ...
File Size: KB Bulletin
... There won’t be any sound output from the unit, but you can scope the digital waveform none the less! DSP2 IC is under here. ...
... There won’t be any sound output from the unit, but you can scope the digital waveform none the less! DSP2 IC is under here. ...
Controls Training Course
... Explain how the development of the triac has made HVACR controls more versatile. Explain the difference between a triac and a SCR. Describe how a triac is Agated on and off. Explain how and why triacs can be used on resistive and inductive loads. Describe the operation of three-phase triac ...
... Explain how the development of the triac has made HVACR controls more versatile. Explain the difference between a triac and a SCR. Describe how a triac is Agated on and off. Explain how and why triacs can be used on resistive and inductive loads. Describe the operation of three-phase triac ...
CDB53L21 - cloudfront.net
... The evaluation board has been designed to allow interfacing with external systems via a serial port header (reference designation J5) and a control port header, “CS53L21 S/W Control.” The serial port header provides access to the serial audio signals required to interface with a DSP (Figure 31 on pa ...
... The evaluation board has been designed to allow interfacing with external systems via a serial port header (reference designation J5) and a control port header, “CS53L21 S/W Control.” The serial port header provides access to the serial audio signals required to interface with a DSP (Figure 31 on pa ...
controlkhati 21
... What is an Op-Amp? • All op-amps use a voltage supply (Vcc) to amplify the signal • The supply voltages can either have equal value but opposite signs, or the low side is grounded and the high side has a value of twice the ...
... What is an Op-Amp? • All op-amps use a voltage supply (Vcc) to amplify the signal • The supply voltages can either have equal value but opposite signs, or the low side is grounded and the high side has a value of twice the ...
Inductive proximity sensors
... The impulse frequency Fc generated by the moving part to be monitored is compared with the frequency Fr preset on the sensor. The output of the sensor is in the closed state for Fc > Fr and in the open state for Fc < Fr. Note : Following “power-up” of the sensor, the “rotation monitoring” function i ...
... The impulse frequency Fc generated by the moving part to be monitored is compared with the frequency Fr preset on the sensor. The output of the sensor is in the closed state for Fc > Fr and in the open state for Fc < Fr. Note : Following “power-up” of the sensor, the “rotation monitoring” function i ...
Atmel AT42QT1011 Single-key QTouch Touch Sensor IC Features
... The value of Cs also has a dramatic effect on sensitivity, and this can be increased in value with the trade-off of slower response time and more power. Increasing the electrode's surface area will not substantially increase touch sensitivity if its diameter is already much larger in surface area t ...
... The value of Cs also has a dramatic effect on sensitivity, and this can be increased in value with the trade-off of slower response time and more power. Increasing the electrode's surface area will not substantially increase touch sensitivity if its diameter is already much larger in surface area t ...
A Wide Tuning Range mm
... while a higher current is used at lower oscillating frequencies -where it is needed due to the larger tank losses- a smaller current can be used at higher frequencies. This way, the power consumption of the circuit is managed without degrading the phase noise performance. Simulation results of the t ...
... while a higher current is used at lower oscillating frequencies -where it is needed due to the larger tank losses- a smaller current can be used at higher frequencies. This way, the power consumption of the circuit is managed without degrading the phase noise performance. Simulation results of the t ...
Interface Connection Connectors
... *The dimples in the plug shell ensure continuity between it and the socket shell, thus providing complete shielding. ...
... *The dimples in the plug shell ensure continuity between it and the socket shell, thus providing complete shielding. ...
ZXTC2063E6 Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Product information - VEGABAR 86 VEGABAR 87 VEGAWELL 52
... the operating instructions manual of the respective instrument. Provide a reliable separation between the supply circuit and the mains circuits according to DIN EN 61140 VDE 0140-1. Specifications of the voltage supply: ...
... the operating instructions manual of the respective instrument. Provide a reliable separation between the supply circuit and the mains circuits according to DIN EN 61140 VDE 0140-1. Specifications of the voltage supply: ...
MPA 5150 SS 5 Channel Power Amp Manual
... HEAT DISSIPATION The Monster Amp is a high current design, and like all amplifiers, will produce heat under normal operating conditions. To maintain proper operation of your amplifiers: DO NOT stack your amplifiers in an enclosed environment such as closets or completely enclosed audio racks. When p ...
... HEAT DISSIPATION The Monster Amp is a high current design, and like all amplifiers, will produce heat under normal operating conditions. To maintain proper operation of your amplifiers: DO NOT stack your amplifiers in an enclosed environment such as closets or completely enclosed audio racks. When p ...
DS3231M ±5ppm, I C Real-Time Clock 2
... temperature conversions are executed once per second. When VBAT is the presently selected power source, temperature conversions are executed once every 10s. To preserve the battery, the first time VBAT is applied to the device the oscillator does not start up until VCC exceeds VPF or until a valid I ...
... temperature conversions are executed once per second. When VBAT is the presently selected power source, temperature conversions are executed once every 10s. To preserve the battery, the first time VBAT is applied to the device the oscillator does not start up until VCC exceeds VPF or until a valid I ...
Tech Note MSP to Aromat(NAiS) FP0 Revision: 4.9 Following are
... software used for testing. This file also contains the setup parameters used for testing. 8. Scan Time. The key to getting the driver to function properly is to get the driver code executed and PLC I/O for the MSP updated at constant time intervals. The FP0 PLCs have the ability to fix the scan of t ...
... software used for testing. This file also contains the setup parameters used for testing. 8. Scan Time. The key to getting the driver to function properly is to get the driver code executed and PLC I/O for the MSP updated at constant time intervals. The FP0 PLCs have the ability to fix the scan of t ...
Power Electronics - Talking Electronics
... value, any portion of both positive and negative half-cycles of a.c. supply can be made to flow through the load. This permits to adjust the transfer of a.c. power from the source to the load. Example 21.1. Draw the transistor equivalent circuit of a triac and explain its operation from this equival ...
... value, any portion of both positive and negative half-cycles of a.c. supply can be made to flow through the load. This permits to adjust the transfer of a.c. power from the source to the load. Example 21.1. Draw the transistor equivalent circuit of a triac and explain its operation from this equival ...
PAM2800 Description Pin Assignments
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
REF1004-1.2 数据资料 dataSheet 下载
... The REF1004-1.2 and REF1004-2.5 are two terminal bandgap reference diodes designed for high accuracy with outstanding temperature characteristics at low operating currents. Prior to the introduction of the REF1004 Micropower Voltage References, accuracy and stability specifications could only be att ...
... The REF1004-1.2 and REF1004-2.5 are two terminal bandgap reference diodes designed for high accuracy with outstanding temperature characteristics at low operating currents. Prior to the introduction of the REF1004 Micropower Voltage References, accuracy and stability specifications could only be att ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.