• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
KX-TG4012LAT KX-TG4013LAT KX-TGA403LAT
KX-TG4012LAT KX-TG4013LAT KX-TGA403LAT

... • Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work. 1. When repair services are provided, neither the products nor their parts or members shall be rem ...
Servo Ventilator 300/300A - Frank`s Hospital Workshop
Servo Ventilator 300/300A - Frank`s Hospital Workshop

Axis controller CPX-CMAX-C1-1 Terminal CPX
Axis controller CPX-CMAX-C1-1 Terminal CPX

Installation Manual
Installation Manual

... triggered. This wire should be connected to an external relay and wired to the vehicles interior entry lighting circuit whenever the optional Entry Interior Illumination feature is desired. 2 LT. Blue Wire: Ground Output While Running (-) 300mA This wire provides a 300mA ground output that becomes a ...
SEL-734 Quick
SEL-734 Quick

... QuickSet automatically hides unavailable configuration settings and flags invalid configuration settings at the bottom of the screen. Right-click on any setting for the previous or default value. ...
ScanTAP IsoPod User`s Manual
ScanTAP IsoPod User`s Manual

... 1. The ScanTAP IsoPod supports 3.3V TAP signals 2. The ScanTAP IsoPod and its cabling contributes to signal quality degradation, requiring the maximum TCK be reduce by 15% on average 3. The ScanTAP IsoPod supports JTAG test clock (TCK) frequencies up to 40 MHz 4. The ScanTAP IsoPod supports I2C and ...
UN shall mean rated (nominal) voltage
UN shall mean rated (nominal) voltage

NIST Measurement Service for DC Standard Resistors
NIST Measurement Service for DC Standard Resistors

... the current I in the Hall device and is given by RH(i) = VH(i)/I = RK/i, where the von Klitzing constant RK is believed to be equal to h/e2 , and i is an integer of the quantum Hall state. The value of the U. S. representation of the ohm is consistent with the conventional value of the von Klitzing ...
Electrical System Bonding and Grounding
Electrical System Bonding and Grounding

... is to conduct the currents generated by lightning strikes and other extremely short-duration electrical events. Because the conductivity of the grounding electrode system is relatively low and its resistance is relatively high, as much as 25 ohms, (that translates as 5 amperes at 120 volts), it is n ...
HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual
HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual

... less than or equal to 5% THID for standard HGP Series filters at full load, and less than 8% at 30% load. If a properly sized & installed filter fails to meet its specified THID level, TCI will provide material for necessary modifications or replacement filter at no charge. HG filters can also provi ...
Service Manual
Service Manual

... Industrial ScopeMeter ...
Live Tank Circuit Breakers Application Guide
Live Tank Circuit Breakers Application Guide

... forward. The number of breaking units was reduced; a circuit breaker for 420 kV needed only four interrupters in series per phase. The demand of energy for operation was relatively low, and spring-charged mechanisms could be used. Both the minimum oil circuit breaker and the spring mechanisms are pr ...
INTERNATIONAL STANDARD IEC 60439-1
INTERNATIONAL STANDARD IEC 60439-1

... agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) ...
[3] JP Alegre et al, “SiGe analog circuit for an 802.11a - DR-NTU
[3] JP Alegre et al, “SiGe analog circuit for an 802.11a - DR-NTU

Power Supplies - Peat Wholesale
Power Supplies - Peat Wholesale

... SWITCH-MODE BENCH TOP POWER SUPPLIES This range of power supplies feature electronic voltage control and shortcircuit protection. Ideal for powering CB Radios, communication transceivers and other appliances. Sturdy case fitted with a mains lead and plug. • Output via red and black terminals ...
Cleco electric service standards.
Cleco electric service standards.

... Added Fig. V-1A Multiple Occupancy Structures-Underground with up to 6 Service Laterals277/480V and Fig. V-3A Multiple Occupancy Structures-Overhead with up to 6 Service Laterals-277/480V. The following Sections were modified: 7.20, 8.14, and A4. Modified wording to have customer provide and install ...
Welding 101 - Electrical connection
Welding 101 - Electrical connection

Electric Shock Hazard of Manual Electric Arc Welding
Electric Shock Hazard of Manual Electric Arc Welding

... Use of Safe Welding Equipment Use proper and safe welding equipment. Properly earth the metal casing of welding transformer by connecting separate earth wire to the power source. Attention: The residual current device (RCD) installed at the power source, if there is any, can only give protection ag ...
Reactive Reserves and Generator D-Curves
Reactive Reserves and Generator D-Curves

the zero-pole transformation noise reduction technique for
the zero-pole transformation noise reduction technique for

... sensor and photo-detector systems. Charge amplifiers are used in the front-end design of systems that have an input signal in the form of charge or a current pulse. Applications for such systems include photography, radar imaging, medical imaging, X-ray fluorescence applications and particle-physics ...
Powerware BladeUPS for Data Centers, 12kW single system
Powerware BladeUPS for Data Centers, 12kW single system

... parallel bus, sending information about current battery conditions (voltage). Each UPS shall be able to adjust output load based upon its own battery voltage, therefore systems with incorrectly connected, weak or failed batteries shall assume less load ensuring maximum runtime out of the connected b ...
Avionics Guide
Avionics Guide

... As a member of the SWIFT™ family of DC/DC regulators, the TPS5450 is a high-output-current PWM converter that integrates a low-resistance high-side N-channel MOSFET. Included on the substrate with the listed features are a highperformance voltage error amplifier that provides tight voltage regulatio ...
Thermal
Thermal

Distribution Dry-Type Transformers — Low Voltage
Distribution Dry-Type Transformers — Low Voltage

Ultra3000 Digital Servo Drives Installation Manual
Ultra3000 Digital Servo Drives Installation Manual

... The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley® does not assume responsibility or liability (to include intellec ...
< 1 ... 9 10 11 12 13 14 15 16 17 ... 838 >

Metadyne



A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report