Evaluates: MAX16029/MAX16030/MAX16043 MAX16029 Evaluation Kit General Description Features
... The MAX16029 and the MAX16030/MAX16043 (that can also be evaluated on this EV kit) operate from 2.2V to 28V. They monitor up to four voltages and provide individual outputs (OUT1–OUT4) that indicate if the corresponding input is above or below its threshold. Additionally, each channel has a specific ...
... The MAX16029 and the MAX16030/MAX16043 (that can also be evaluated on this EV kit) operate from 2.2V to 28V. They monitor up to four voltages and provide individual outputs (OUT1–OUT4) that indicate if the corresponding input is above or below its threshold. Additionally, each channel has a specific ...
VOLTMETER/PHASER a n d A C C E S S O... Operating & Instruction Manual
... professionals trained in its use and application in and around high voltage electric equipment. If you are not trained in the work methods required for safe operation, do not proceed until you obtain the training. CAUTION: Do not exceed 40kV without extension resistors. Install one R-80 extension re ...
... professionals trained in its use and application in and around high voltage electric equipment. If you are not trained in the work methods required for safe operation, do not proceed until you obtain the training. CAUTION: Do not exceed 40kV without extension resistors. Install one R-80 extension re ...
PoE Powered Device for 24 VAC Building Power Applications
... Commercial building infrastructures usually include one or more low voltage power systems in addition to the mains power wiring. These low voltage power systems typically provide 24 VAC to various types of devices such as security cameras, thermostats, card readers, door openers, and other conventio ...
... Commercial building infrastructures usually include one or more low voltage power systems in addition to the mains power wiring. These low voltage power systems typically provide 24 VAC to various types of devices such as security cameras, thermostats, card readers, door openers, and other conventio ...
ICM7216B,D
... Oscillator Frequency. This input is available on the lCM7216B only. The implementation of different functions is done by routing the different signals to two counters, called “Main Counter” and “Reference Counter”. A simplified block diagram of the device for functions realization is shown in Figure ...
... Oscillator Frequency. This input is available on the lCM7216B only. The implementation of different functions is done by routing the different signals to two counters, called “Main Counter” and “Reference Counter”. A simplified block diagram of the device for functions realization is shown in Figure ...
IF 1685 Revision 1
... NOTE: Visor and guard can both be used on a floodlight at the same time. Visor and guard ...
... NOTE: Visor and guard can both be used on a floodlight at the same time. Visor and guard ...
GE Control Catalog - Section 3: Lighting Contactors
... 1. Coil operation and control circuit at same or different voltages 2. Allows longer control wiring runs 3. Microprocessor validates control signal before operation —will not respond to momentary voltage spikes or noise —operation command has built in delay (0.4 sec) to avoid multiple short-term com ...
... 1. Coil operation and control circuit at same or different voltages 2. Allows longer control wiring runs 3. Microprocessor validates control signal before operation —will not respond to momentary voltage spikes or noise —operation command has built in delay (0.4 sec) to avoid multiple short-term com ...
Energy Commander - PSG Specification MV (MOA)-A-1
... load, or once a user-defined time has passed, transfer the system load in order of load priority to the engine-generators that are online. Each load shall be controlled by its own ‘load add’ and ‘load shed’ control relays. ...
... load, or once a user-defined time has passed, transfer the system load in order of load priority to the engine-generators that are online. Each load shall be controlled by its own ‘load add’ and ‘load shed’ control relays. ...
BUILD THIS SE AMP
... the standard 1N4005 and the highquality Hexfred diodes are available from AES. When using diodes, you can add some extra filter capacitors to help smooth out your B+, which you can’t always do when using rectifier tubes. I built two of these amps using both types of power supplies, and I can’t reall ...
... the standard 1N4005 and the highquality Hexfred diodes are available from AES. When using diodes, you can add some extra filter capacitors to help smooth out your B+, which you can’t always do when using rectifier tubes. I built two of these amps using both types of power supplies, and I can’t reall ...
seismometers calibration: comparison between a relative
... provided by a measurement standard and the corresponding indication of a measuring result provided by the calibrated device itself. As the seismometers measures ground motions, the calibration standard should be a known ground motion and the result the seismometer electrical signal output. The appli ...
... provided by a measurement standard and the corresponding indication of a measuring result provided by the calibrated device itself. As the seismometers measures ground motions, the calibration standard should be a known ground motion and the result the seismometer electrical signal output. The appli ...
2008 26 Spring Wiring Matters
... circuit are liable to come into contact, either intentionally or fortuitously with the exposed-conductive-parts of other circuits, protection against electric shock no longer depends solely on protection by electrical separation but on the protective provisions to which the latter exposedconductive- ...
... circuit are liable to come into contact, either intentionally or fortuitously with the exposed-conductive-parts of other circuits, protection against electric shock no longer depends solely on protection by electrical separation but on the protective provisions to which the latter exposedconductive- ...
AD9230 12-Bit, 170 MSPS/210 MSPS/250 MSPS, 1.8 V Analog
... responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog ...
... responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog ...
QUICKTRONIC® Outdoor Metal Halide and High Pressure Sodium
... 4. Auto shut down function including end-of-life and thermal protection: a. Disconnect power when servicing. Cycle power to reset ballast after auto shutdown. 5. S tep or 0-10V dimming can be activated after 15 minutes of warm-up at full power. Recommended by NEMA and lamp manufacturers. 6. If co ...
... 4. Auto shut down function including end-of-life and thermal protection: a. Disconnect power when servicing. Cycle power to reset ballast after auto shutdown. 5. S tep or 0-10V dimming can be activated after 15 minutes of warm-up at full power. Recommended by NEMA and lamp manufacturers. 6. If co ...
ADM1169 数据手册DataSheet 下载
... monitoring undervoltage faults, overvoltage faults, or out-ofwindow faults on up to eight supplies. In addition, there are eight programmable outputs that can be used as logic enables. Six of these programmable outputs can also provide up to a 12 V output for driving the gate of an NFET that can be ...
... monitoring undervoltage faults, overvoltage faults, or out-ofwindow faults on up to eight supplies. In addition, there are eight programmable outputs that can be used as logic enables. Six of these programmable outputs can also provide up to a 12 V output for driving the gate of an NFET that can be ...
Instruction manual Unitor Welding Inverter UWI 500 TP & UWF 102
... Line Voltage compensation keeps output of the power source constant regardless of fluctuation in input power from 10% below lowest to above highest rated input voltage. Safe in use. Touchable open circuit voltage only 9V, providing optimal safety for the operator Adjustable Hot Start for MMA provide ...
... Line Voltage compensation keeps output of the power source constant regardless of fluctuation in input power from 10% below lowest to above highest rated input voltage. Safe in use. Touchable open circuit voltage only 9V, providing optimal safety for the operator Adjustable Hot Start for MMA provide ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.