
AD1674 - Analog Devices
... Byte Address/Short Cycle. If a conversion is started with A0 Active LOW, a full 12-bit conversion cycle is initiated. If A0 is Active HIGH during a convert start, a shorter 8-bit conversion cycle results. During Read (R/C = 1) with 12/8 LOW, A0 = LOW enables the 8 most significant bits (DB4–DB11), a ...
... Byte Address/Short Cycle. If a conversion is started with A0 Active LOW, a full 12-bit conversion cycle is initiated. If A0 is Active HIGH during a convert start, a shorter 8-bit conversion cycle results. During Read (R/C = 1) with 12/8 LOW, A0 = LOW enables the 8 most significant bits (DB4–DB11), a ...
Agile Mixed Signal Addresses Analog Design Challenges
... As seen in Figure 4, the flexibility of the XADC block supports the complex data acquisition needs of an application like motor control. The simultaneous sampling capability of the dual ADCs in the XADC block allow simultaneous sampling of Ia and Ib (stator currents) to preserve the phase relationsh ...
... As seen in Figure 4, the flexibility of the XADC block supports the complex data acquisition needs of an application like motor control. The simultaneous sampling capability of the dual ADCs in the XADC block allow simultaneous sampling of Ia and Ib (stator currents) to preserve the phase relationsh ...
Lee Feder repaired and restored a Fender Twin Reverb Amp
... Once the overdrive circuit was installed, I turned to cleaning up the overall sound of the amplifier. According to the theory of tube operation, a filament drawing 6.3 volts off an alternative secondary winding on the power transformer heats the cathode in the tube. Due to the property of thermioni ...
... Once the overdrive circuit was installed, I turned to cleaning up the overall sound of the amplifier. According to the theory of tube operation, a filament drawing 6.3 volts off an alternative secondary winding on the power transformer heats the cathode in the tube. Due to the property of thermioni ...
WE 286A - Western Electric
... In addition to its amplifier applications, the tube is also effective as a shielded modulator. Due to the low capacitance between the first and third grids, separate inputs may be applied to these elements without appreciable interaction. Both of these grids are negative for such use, so that the po ...
... In addition to its amplifier applications, the tube is also effective as a shielded modulator. Due to the low capacitance between the first and third grids, separate inputs may be applied to these elements without appreciable interaction. Both of these grids are negative for such use, so that the po ...
AD676 - Analog Devices
... perform the actual analog-to-digital conversion. The capacitor array eliminates variation in the linearity of the device due to temperature-induced mismatches of resistor values. Since a capacitor array is used to perform the data conversions, the sample/hold function is included without the need fo ...
... perform the actual analog-to-digital conversion. The capacitor array eliminates variation in the linearity of the device due to temperature-induced mismatches of resistor values. Since a capacitor array is used to perform the data conversions, the sample/hold function is included without the need fo ...
Ai-762 Analog Test Instrument
... of features makes the Ai-762 the ideal analog test instrument to leverage past test program set (TPS) investment as well as capture the benefits of operational test. As with all instruments in Teradyne’s Core Systems Instrumentation (CSi) family, the Ai-762 combines greater levels of functionality a ...
... of features makes the Ai-762 the ideal analog test instrument to leverage past test program set (TPS) investment as well as capture the benefits of operational test. As with all instruments in Teradyne’s Core Systems Instrumentation (CSi) family, the Ai-762 combines greater levels of functionality a ...
LabVIEW Part 3
... Differential connections are typically used with signals under one volt or when the instrumentation does not meet the criteria for RSE. In a system wired for differential inputs, each input has its own reference. Differential inputs are also useful as they eliminate noise problems because any common ...
... Differential connections are typically used with signals under one volt or when the instrumentation does not meet the criteria for RSE. In a system wired for differential inputs, each input has its own reference. Differential inputs are also useful as they eliminate noise problems because any common ...
TESLA 4000 Data Sheet
... TESLA has advanced communication capabilities and, together with its powerful recording features, provides the most versatile and complete monitoring of power system health. The TESLA, with over 1000 user definable triggers, creates records simultaneously in 3 time domains – fault (fast), swing (slo ...
... TESLA has advanced communication capabilities and, together with its powerful recording features, provides the most versatile and complete monitoring of power system health. The TESLA, with over 1000 user definable triggers, creates records simultaneously in 3 time domains – fault (fast), swing (slo ...
S.Khan
... ty in which the muscle fibres contract and relax in an orchestrated sequence. These waves cause weak currents to flow in the body, changing the relative elec tric potential between different points on the skin by about 1mV. The signals can change sharply in as little as one fiftieth of a second. So ...
... ty in which the muscle fibres contract and relax in an orchestrated sequence. These waves cause weak currents to flow in the body, changing the relative elec tric potential between different points on the skin by about 1mV. The signals can change sharply in as little as one fiftieth of a second. So ...
How to Measure the Loop Transfer Function of Power Supplies (Rev
... In order to take a full bode plot, the signal generator frequency is swept and at different points the gain as the amplitude relationship between the two channels and the phase shift are measured. Depending on the oscilloscope used for the measurement and the gain of the loop, it might be very diffi ...
... In order to take a full bode plot, the signal generator frequency is swept and at different points the gain as the amplitude relationship between the two channels and the phase shift are measured. Depending on the oscilloscope used for the measurement and the gain of the loop, it might be very diffi ...
20080300_TRDmeeting_report
... • Signal share is less than 3 pads. • Gas gain by avalanche can be fitted by exponential function of anode voltage. • Drift velocity in Ar gas is about three times larger than that in Xe gas. • The attenuation of signal by hydrogen and oxygen depends on time that electrons stay in the chamber. • abs ...
... • Signal share is less than 3 pads. • Gas gain by avalanche can be fitted by exponential function of anode voltage. • Drift velocity in Ar gas is about three times larger than that in Xe gas. • The attenuation of signal by hydrogen and oxygen depends on time that electrons stay in the chamber. • abs ...
VERS-1 Erin Browning Matthew Mohn Michael Senejoa Motivation
... When designing a synthesizer guitar, the first big issue of the project is how to read, process and synthesize a note correctly. The best solution for this problem was found in the past by the audio processing company Roland. Their solution was to first isolate every string’s pickup versus the norma ...
... When designing a synthesizer guitar, the first big issue of the project is how to read, process and synthesize a note correctly. The best solution for this problem was found in the past by the audio processing company Roland. Their solution was to first isolate every string’s pickup versus the norma ...
AD1380 数据手册DataSheet 下载
... CONVERT START signal sets the STATUS flag, indicating conversion in progress. This, in turn, removes the inhibit applied to the gated clock, permitting it to run through 17 cycles. All the SAR parallel bits, STATUS flip-flops and the gated clock inhibit signal are initialized on the trailing edge of ...
... CONVERT START signal sets the STATUS flag, indicating conversion in progress. This, in turn, removes the inhibit applied to the gated clock, permitting it to run through 17 cycles. All the SAR parallel bits, STATUS flip-flops and the gated clock inhibit signal are initialized on the trailing edge of ...
Experiment 1-7
... Should the effective sampling rate be increased or decreased in order to improve the frequency resolution of the FFT? ...
... Should the effective sampling rate be increased or decreased in order to improve the frequency resolution of the FFT? ...
Untitled
... The Nature Of Tubes: Why (And When) To Replace Them: Tubes are made up of a number of fragile mechanical components that are vacuum-sealed in a glass envelope or bubble. The tube's longevity is based on a number of factors which include how hard and often the amplifier is played, vibration from the ...
... The Nature Of Tubes: Why (And When) To Replace Them: Tubes are made up of a number of fragile mechanical components that are vacuum-sealed in a glass envelope or bubble. The tube's longevity is based on a number of factors which include how hard and often the amplifier is played, vibration from the ...
330R 1/8 DIN Process Monitor and Indicator
... • Square root linearization results in accurate measurement from flow transmitters with nonlinear outputs, saving the expense of a separate square root extractor. • User-definable 15-point linearization allows customized linearization of the input signal for highly accurate measurements in engineeri ...
... • Square root linearization results in accurate measurement from flow transmitters with nonlinear outputs, saving the expense of a separate square root extractor. • User-definable 15-point linearization allows customized linearization of the input signal for highly accurate measurements in engineeri ...
Oscilloscope types

This is a subdivision of the Oscilloscope article, discussing the various types and models of oscilloscopes in greater detail.