Electronic Instruments
... trouble shooting since they permit readings to be taken so that circuit faults can be located by ascertaining which component values do not coincide with the pre-established values indicated by the manufacturer. In fact, electronic instruments are playing a vital role in the fast developing field of ...
... trouble shooting since they permit readings to be taken so that circuit faults can be located by ascertaining which component values do not coincide with the pre-established values indicated by the manufacturer. In fact, electronic instruments are playing a vital role in the fast developing field of ...
Using Open-Source TCP/IP Stacks - Renesas e
... display on a gauge How often should you monitor What is the update rate on the display ? Oversample and filter at least 8:1 Consider taking 10 samples, throw out high and low and average rest Evenly spaced measurements tend to minimize noise affects ...
... display on a gauge How often should you monitor What is the update rate on the display ? Oversample and filter at least 8:1 Consider taking 10 samples, throw out high and low and average rest Evenly spaced measurements tend to minimize noise affects ...
a Dual Sigma-Delta ADC with Auxiliary DAC AD7729
... reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. ...
... reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. ...
Analog annunciator unit Features Application
... • A full choice of 26 standardized fieldselectable channel input signal types • Four alarm/trip levels per channel; two low set and two high set points • The last thirty events with time markings stored for local presentation • Bar graph, curve or numerical display of set and measured parameter valu ...
... • A full choice of 26 standardized fieldselectable channel input signal types • Four alarm/trip levels per channel; two low set and two high set points • The last thirty events with time markings stored for local presentation • Bar graph, curve or numerical display of set and measured parameter valu ...
A Variable Duty Factor Beam Chopper for a 300 keV Injection
... design also has a limited requirement for pulse duration, which is in the range 500 ns to 6 ps[2]. The 300 keV beam chopper consists of three stages to convert a TTL timing signal, from the ISIS control system, to a 5 kV pulse. The first stage converts the TTL signal to 60 V; the second stage conver ...
... design also has a limited requirement for pulse duration, which is in the range 500 ns to 6 ps[2]. The 300 keV beam chopper consists of three stages to convert a TTL timing signal, from the ISIS control system, to a 5 kV pulse. The first stage converts the TTL signal to 60 V; the second stage conver ...
DN2.49x - 16 channel 16 bit digitizerNETBOX up to 60 MS/s
... The Gated Sampling mode allows data recording controlled by an external gate signal. Data is only recorded if the gate signal has a programmed level. In addition a pre-area before start of the gate signal as well as a post area after end of the gate signal can be acquired. The number of gate segment ...
... The Gated Sampling mode allows data recording controlled by an external gate signal. Data is only recorded if the gate signal has a programmed level. In addition a pre-area before start of the gate signal as well as a post area after end of the gate signal can be acquired. The number of gate segment ...
HT9170 DTMF Receiver
... When the voltage of RT/GT changes from 0 to VTRT (2.35V for 5V supply), the input signal is effective, and the correct code will be created by the code detector. After D0~D3 are completely latched, DV output becomes high. When the voltage of RT/GT falls down from VDD to VTRT (i.e.., when there is no ...
... When the voltage of RT/GT changes from 0 to VTRT (2.35V for 5V supply), the input signal is effective, and the correct code will be created by the code detector. After D0~D3 are completely latched, DV output becomes high. When the voltage of RT/GT falls down from VDD to VTRT (i.e.., when there is no ...
FAQs for SmartLEWIS RX+ family: TDA5240, TDA5235, TDA5225
... + 1µF) as shown in the datasheet. The time constant of the 22Ohm resistor together with the 1µF capacitor has to be kept constant. That means a 4.7Ohm resistor together with 4.7µF capacitor can be used as well to overcome possible voltage drop across this resistor, which could reduce the supply volt ...
... + 1µF) as shown in the datasheet. The time constant of the 22Ohm resistor together with the 1µF capacitor has to be kept constant. That means a 4.7Ohm resistor together with 4.7µF capacitor can be used as well to overcome possible voltage drop across this resistor, which could reduce the supply volt ...
MT-079: Analog Multipliers
... Figure 1: Basic Analog Multiplier and Definition of Multiplier Quadrants From a mathematical point of view, multiplication is a "four quadrant" operation—that is to say that both inputs may be either positive or negative, as may be the output. Some of the circuits used to produce electronic multipli ...
... Figure 1: Basic Analog Multiplier and Definition of Multiplier Quadrants From a mathematical point of view, multiplication is a "four quadrant" operation—that is to say that both inputs may be either positive or negative, as may be the output. Some of the circuits used to produce electronic multipli ...
INTRODUCTION
... There are other reasons why ammeters are less than ideal but many of these are beyond the scope of this experiment. In this lab we will be working with multimeters rather than ammeters—specifically analog multimeters and digital multimeters. A basic analog multimeter consists of an ammeter combined ...
... There are other reasons why ammeters are less than ideal but many of these are beyond the scope of this experiment. In this lab we will be working with multimeters rather than ammeters—specifically analog multimeters and digital multimeters. A basic analog multimeter consists of an ammeter combined ...
RX7 Stimulator Base Station
... ~100 kHz. This will allow an RX7 to run a DSP chain at ~50 kHz or ~100 kHz, and still sample data acquired through an optically connected preamplifier that digitized the incoming data stream at its maximum rate of ~25 kHz. Oversampling is performed on the base station. The signals being acquired wil ...
... ~100 kHz. This will allow an RX7 to run a DSP chain at ~50 kHz or ~100 kHz, and still sample data acquired through an optically connected preamplifier that digitized the incoming data stream at its maximum rate of ~25 kHz. Oversampling is performed on the base station. The signals being acquired wil ...
ADS930 数据资料 dataSheet 下载
... two-bit quantizer stage converts on the edge of the subclock, which is the same frequency of the externally applied clock. The output of each quantizer is fed into its own delay line to time-align it with the data created from the subsequent quantizer stages. This aligned data is fed into a digital ...
... two-bit quantizer stage converts on the edge of the subclock, which is the same frequency of the externally applied clock. The output of each quantizer is fed into its own delay line to time-align it with the data created from the subsequent quantizer stages. This aligned data is fed into a digital ...
comp_proj_report1
... Digital Signal Processors (DSPs) are often used to process analog signals that are both sampled and quantized. Since every sample must be stored in the processor with only a finite number of bits, some quantization error inevitably results. Consider a fixed-point DSP. Fixed point means that the posi ...
... Digital Signal Processors (DSPs) are often used to process analog signals that are both sampled and quantized. Since every sample must be stored in the processor with only a finite number of bits, some quantization error inevitably results. Consider a fixed-point DSP. Fixed point means that the posi ...
Fluke-175, Fluke-177, Fluke-179
... Versatile meters for maintenance, field service and bench repair. The 170 Series have the features needed to find most electrical, electronic, electro-mechanical and heating and ventilation problems. They are simple to use and have significant improvements over Fluke’s original 70 Series like true-r ...
... Versatile meters for maintenance, field service and bench repair. The 170 Series have the features needed to find most electrical, electronic, electro-mechanical and heating and ventilation problems. They are simple to use and have significant improvements over Fluke’s original 70 Series like true-r ...
Configuring an Enwatch unit to Piggy-back a Bently Rack
... levels of +/- 10vDC. Commonly, NCPU’s are physically gapped at 50 to 60 mils or 1012vDC electrical GAP. Unfortunately the Enwatch unit will NOT accept voltage inputs of these levels. For this reason, a “Voltage Attenuator” (EIRD P/N 44826) is used to lower the GAP voltage below the +/- 10vDC thresho ...
... levels of +/- 10vDC. Commonly, NCPU’s are physically gapped at 50 to 60 mils or 1012vDC electrical GAP. Unfortunately the Enwatch unit will NOT accept voltage inputs of these levels. For this reason, a “Voltage Attenuator” (EIRD P/N 44826) is used to lower the GAP voltage below the +/- 10vDC thresho ...
RF - Indico
... – not clear how this can be reduced by pre-processing simple pre-analysis with extraction of gains, phases, signal levels etc. and their comparison with reference values might be possible in the Front-End ...
... – not clear how this can be reduced by pre-processing simple pre-analysis with extraction of gains, phases, signal levels etc. and their comparison with reference values might be possible in the Front-End ...
Oscilloscope types

This is a subdivision of the Oscilloscope article, discussing the various types and models of oscilloscopes in greater detail.