• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
412 Laboratory #1: Input Resistance, Output Resistance, and
412 Laboratory #1: Input Resistance, Output Resistance, and

... Q4: Based on this measurement only, determine the apparent smallsignal voltage gain Av  vo vi with this output load applied. Q5: Now use your equivalent amplifier circuit model (i.e., not the equivalent small-signal MOSFET model) to calculate the theoretic voltage gain. In other words, connect the ...
Circuits
Circuits

... you would like its resistance to be as large as possible in order to affect the circuit as little as possible ...
Measurement of internal work during running
Measurement of internal work during running

... • amplifiers usually have +/–10 V or more, oscilloscopes and multimeters (+/–200 V or more) • tape or minidisk recorders have +/–1.25 V • EMG signals must be amplified usually 1000x or more but not too high to cause amplifier “saturation” (signal overload) • if too low, numerical resolution will com ...
IC 555 TIMER
IC 555 TIMER

BMC012. Variable Stepped Voltage Generator
BMC012. Variable Stepped Voltage Generator

... Patch 1. In this patch a BMC004 Clock/Divider is generating several outputs that are divisions of the same clock. Some of these divisions are plugged into the Increase/Decrease inputs of the Stepped CV Generator, and one division is going to the input of an envelope generator. The voltage generator' ...
1E6 Electricity and Magnetism
1E6 Electricity and Magnetism

... There is a maximum frequnecy which is passed by the amplifier with full gain. There is a limit to the rate of change in the signal which the amplifier can handle. Frequency components outside of the bandwidth of the amplifier are attenuated and this can lead to distortion f the signal. ...
Princeton
Princeton

... CMOS technology. Which accept analog audio input signal, a high sample rate ADC transfer the analog signal into a bit stream then storage to internal 44Kbit RAM, after processing the bit stream will de-modulate by DAC and lowpass filter. Overall delay time is determined by internal VCO clock frequen ...
MPPT Tracking Test Procedure
MPPT Tracking Test Procedure

DTMF decoder
DTMF decoder

... The HT9170 series tone decoders consist of three band pass filters and two digital decode circuits to convert a tone (DTMF) signal into digital code output. The pre-filter is a band rejection filter which reduces the dialing tone from 350Hz to 400Hz. The low group filter filters low group frequency ...
Analog to Digital Converter
Analog to Digital Converter

class c amplifiers
class c amplifiers

... previous cycle because of energy loss in the resistance of the tank circuit, as shown in Figure 6 (a), and the oscillation will eventually die out. However, the regular recurrences of the collector current pulse re-energise the resonant circuit and sustain the oscillations at constant amplitude. Whe ...
Diodes
Diodes

... photons. Because the photoeffect depends upon minority carriers, the diode is biased in he reversed condition for normal operation as a light-sensitive device. Use the PN323B pin diode in the circuit below to show a large increase in diode current when a bright lamp is brought close to the diode. Wh ...
ES330 Laboratory Experiment No. 1 NPN Common
ES330 Laboratory Experiment No. 1 NPN Common

DRN4-Multiple DDC Signal Input to Proportional Resistance Output
DRN4-Multiple DDC Signal Input to Proportional Resistance Output

... When using a triac input signal from an external controller, a Triac Adapter Kit must be ordered with the DRN4. Connect the black common (-) wire from the power source, and the black common wire on the triac adapter to the incoming power lead. Suggestion: Clip off a short section of the power wire t ...
The ”digital” ADC
The ”digital” ADC

... The FM encoder The analog “problems” have been pushed to the encoding of the analog state as an FM coded variable. There are several ways to do this, but in the end, the quality of this encoding determines the overall performance. The most crucial parameter is the noise performance. Also linearity i ...
Breadboard Schematic
Breadboard Schematic

... As digital circuits are required to handle just two levels of voltage – to represent the two possible values of any binary variable, functional testing of simple digital circuits can be conveniently carried out by applying each input (binary) variable through a switch and observing each output (bina ...
WIO-12 - Legrand
WIO-12 - Legrand

... The following instructions are general guidelines for proper installation of the device. Any question should be directed to Wattstopper prior to installation. It is the responsibility of the installer to ensure local, state, and federal codes are followed. 1. Disconnect all power prior to installat ...
Mobile Radiographic Equipment
Mobile Radiographic Equipment

... The exposure hand-switch cable must be at least 2 m long to allow radiographer to stand distant from irradiated patient  Lead protection must be used for personnel not involved with the examination  Protect other staff not involve with the ...
POWER ELECTRONICS NOTES 10ES45
POWER ELECTRONICS NOTES 10ES45

... The thyristor T1 is forward biased during the positive half cycle of input ac supply. It can be triggered and made to conduct by applying a suitable gate trigger pulse only during the positive half cycle of input supply. When T1 is triggered it conducts and the load current flows through the thyrist ...
Infrared PWM Transmitter
Infrared PWM Transmitter

... frequency. Although our infrared transmitter will ultimately operate at 40 kHz, we are going to start with a lower frequency for the early prototyping stage. ...
Unit 7: MOSFET-Output Motor Controller
Unit 7: MOSFET-Output Motor Controller

... discharged more rapidly with a given driver circuit, thus reducing switching losses. In addition, the low reverse transfer capacitance helps prevent the MOSFET from turning on when subjected to high rates of voltage increase (dV/dt) at its drain terminal. This is typically a problem for a lowside sw ...
Program-Controlled High-Voltage Pulse Generator for Ion Beams
Program-Controlled High-Voltage Pulse Generator for Ion Beams

Analogue Digital Conversion
Analogue Digital Conversion

... of bits in the codeword absolute accuracy of conversion may not be as good as the resolution if the error tolerance for reference voltages gets too large A multiplexer enables one A-D converter to be switched between several signal inputs ...
Theory of Operations - University of Portland
Theory of Operations - University of Portland

... resistors and a parallel capacitor. They are commonly referred to as a charge pump because voltage is constantly being pumped into and out of the capacitor. When the incoming signal from the PFD is logic high, the capacitor charges up, increasing the output control voltage. When the incoming signal ...
Labf2003_8
Labf2003_8

< 1 ... 336 337 338 339 340 341 342 343 344 ... 395 >

Oscilloscope history



This article discusses the history and development of oscilloscope technology.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report