care and feeding of power grid tubes - F1FRV
... for new equipment design and for replacement of older triode, tetrode and pentode tubes in the redesign of older equipment. Compact EIMAC tubes feature reduced internal coupling between input and output circuits, low internal inductance and capacitance, improved linearity and high operating efficien ...
... for new equipment design and for replacement of older triode, tetrode and pentode tubes in the redesign of older equipment. Compact EIMAC tubes feature reduced internal coupling between input and output circuits, low internal inductance and capacitance, improved linearity and high operating efficien ...
ACS710 Datasheet - Allegro Microsystems
... sensor linearly tracks the magnetic field generated by the applied current. The accuracy of the ACS710 is maximized with this patented packaging configuration because the Hall element is situated in extremely close proximity to the current to be measured. High-level immunity to current conductor dV/ ...
... sensor linearly tracks the magnetic field generated by the applied current. The accuracy of the ACS710 is maximized with this patented packaging configuration because the Hall element is situated in extremely close proximity to the current to be measured. High-level immunity to current conductor dV/ ...
SmartFusion cSoC: DC Fan Control Using PWM
... and thus consumes a lot of power, additionally creating noise. 2. Linear control: In this method the DC voltage applied to the fan is controlled though a voltage regulator. To run the fan at a lower speed the voltage is decreased, and to run at a higher speed the voltage is increased. The advantage ...
... and thus consumes a lot of power, additionally creating noise. 2. Linear control: In this method the DC voltage applied to the fan is controlled though a voltage regulator. To run the fan at a lower speed the voltage is decreased, and to run at a higher speed the voltage is increased. The advantage ...
Total Control Board
... The enclosure of the Control Board should be mounted in a location convenient for the operator or maintenance personnel. Since the display provides visual warning of problems and operating conditions, much of its value is lost if the location does not permit continuous observation. For the longest, ...
... The enclosure of the Control Board should be mounted in a location convenient for the operator or maintenance personnel. Since the display provides visual warning of problems and operating conditions, much of its value is lost if the location does not permit continuous observation. For the longest, ...
Installation Manual
... SW2 (-) or Tach switch The SW2 terminal is used for selecting the various RPM, engine, and performance displays and also for entering the demonstration mode. The SW2 input is activated by a ground connection. The push button switch supplied (or any normally open, momentary switch) is wired by connec ...
... SW2 (-) or Tach switch The SW2 terminal is used for selecting the various RPM, engine, and performance displays and also for entering the demonstration mode. The SW2 input is activated by a ground connection. The push button switch supplied (or any normally open, momentary switch) is wired by connec ...
PM-300 COLLINS 30L-1 REPLACEMENT POWER SUPPLY
... At this point there will be two (2) unconnected WHITE/RED wires that were unsoldered earlier; one that was connected to the old rectifier PCB below the chassis and another that was connected to the old filter capacitor PCB above the chassis. These 2 wires are connected together at an unused lug on b ...
... At this point there will be two (2) unconnected WHITE/RED wires that were unsoldered earlier; one that was connected to the old rectifier PCB below the chassis and another that was connected to the old filter capacitor PCB above the chassis. These 2 wires are connected together at an unused lug on b ...
BD9611MUV
... CLH-CLL voltage when the gate is driven high. The CLH-CLL voltage is compared to the threshold voltage configured by the RCL resistor. If the CLH-CLL voltage exceeds the threshold, the switching pulse is immediately terminated. The FET remains off until the next switching cycle is initiated. The sec ...
... CLH-CLL voltage when the gate is driven high. The CLH-CLL voltage is compared to the threshold voltage configured by the RCL resistor. If the CLH-CLL voltage exceeds the threshold, the switching pulse is immediately terminated. The FET remains off until the next switching cycle is initiated. The sec ...
LP5912 500-mA Low-Noise, Low-IQ LDO (Rev. D)
... For VOUT(NOM) ≥ 3.3 V: VOUT(NOM) + 0.5 V ≤ VIN ≤ 6.5 V, IOUT = 1 mA to 500 mA For 1.1 V ≤ VOUT(NOM) < 3.3 V: VOUT(NOM) + 0.5 V ≤ VIN ≤ 6.5 V, IOUT = 1 mA to 500 mA ...
... For VOUT(NOM) ≥ 3.3 V: VOUT(NOM) + 0.5 V ≤ VIN ≤ 6.5 V, IOUT = 1 mA to 500 mA For 1.1 V ≤ VOUT(NOM) < 3.3 V: VOUT(NOM) + 0.5 V ≤ VIN ≤ 6.5 V, IOUT = 1 mA to 500 mA ...
Introduction to Digital Logic with Laboratory Exercises
... This text will be geared toward computer science students; however it would be appropriate for any students who have the necessary background in algebra and elementary DC electronics. Computer science students learn skills in analysis, design and debugging. These skills are also used in the virtual ...
... This text will be geared toward computer science students; however it would be appropriate for any students who have the necessary background in algebra and elementary DC electronics. Computer science students learn skills in analysis, design and debugging. These skills are also used in the virtual ...
ADCLK854 数据手册DataSheet 下载
... for operation over the standard industrial temperature range of −40°C to +85°C. ...
... for operation over the standard industrial temperature range of −40°C to +85°C. ...
THS413x High-Speed, Low-Noise, Fully
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
Old Company Name in Catalogs and Other Documents
... below VREF, the signal output from the Vo1 pin is changed from the high to the low level. Since the characteristic includes hysteresis, the signal output from the Vo1 pin changes from the low to the high level when the voltage input on pin Vi1 rises to or above VREF+VHYS. Refer to the timing diagram ...
... below VREF, the signal output from the Vo1 pin is changed from the high to the low level. Since the characteristic includes hysteresis, the signal output from the Vo1 pin changes from the low to the high level when the voltage input on pin Vi1 rises to or above VREF+VHYS. Refer to the timing diagram ...
LT1806/LT1807 - 325MHz, Single/Dual, Rail-to-Rail Input and Output, Low Distortion, Low Noise Precision Op Amps
... The LT1806/LT1807 have a very low distortion of – 80dBc at 5MHz, a low input referred noise voltage of 3.5nV/√Hz and a maximum offset voltage of 550μV that allows them to be used in high performance data acquisition systems. The LT1806/LT1807 have an input range that includes both supply rails and a ...
... The LT1806/LT1807 have a very low distortion of – 80dBc at 5MHz, a low input referred noise voltage of 3.5nV/√Hz and a maximum offset voltage of 550μV that allows them to be used in high performance data acquisition systems. The LT1806/LT1807 have an input range that includes both supply rails and a ...
MAX9995 Dual, SiGe, High-Linearity, 1700MHz to 2700MHz Downconversion Mixer with LO Buffer/Switch
... The MAX9995 dual, high-linearity, downconversion mixer provides 6.1dB gain, +25.6dBm IIP3, and 9.8dB NF for WCDMA, TD-SCDMA, LTE, TD-LTE, and GSM/EDGE base-station applications. This device integrates baluns in the RF and LO ports, a dual-input LO selectable switch, an LO buffer, two doublebalanced ...
... The MAX9995 dual, high-linearity, downconversion mixer provides 6.1dB gain, +25.6dBm IIP3, and 9.8dB NF for WCDMA, TD-SCDMA, LTE, TD-LTE, and GSM/EDGE base-station applications. This device integrates baluns in the RF and LO ports, a dual-input LO selectable switch, an LO buffer, two doublebalanced ...
a single-phase dual-output ac-dc converter with high
... This Thesis is brought to you for free and open access by the Graduate School at UKnowledge. It has been accepted for inclusion in University of Kentucky Master's Theses by an authorized administrator of UKnowledge. For more information, please contact [email protected]. ...
... This Thesis is brought to you for free and open access by the Graduate School at UKnowledge. It has been accepted for inclusion in University of Kentucky Master's Theses by an authorized administrator of UKnowledge. For more information, please contact [email protected]. ...
The SR560 (manual - Stanford Research Systems
... range from 0.03 Hz to 1 MHz, and the slope of the rolloff is shown by one of the four ROLLOFF LED’s. When the filter section is configured as band-pass (iii), the cutoff frequencies are illuminated by two LED’s. The frequency setting on the left marks the cutoff for the high-pass filter, and the set ...
... range from 0.03 Hz to 1 MHz, and the slope of the rolloff is shown by one of the four ROLLOFF LED’s. When the filter section is configured as band-pass (iii), the cutoff frequencies are illuminated by two LED’s. The frequency setting on the left marks the cutoff for the high-pass filter, and the set ...
Atmel AVR1300: Using the Atmel AVR XMEGA ADC
... The gain stage does not load the input; hence external signal sources will see very high input impedance for channels that use the gain stage. This is useful for measuring weak signal sources. More details can be found in the datasheet for the specific device. The voltage on any of the two inputs ca ...
... The gain stage does not load the input; hence external signal sources will see very high input impedance for channels that use the gain stage. This is useful for measuring weak signal sources. More details can be found in the datasheet for the specific device. The voltage on any of the two inputs ca ...
LP5912 500-mA Low-Noise, Low-IQ LDO (Rev. D)
... For VOUT(NOM) ≥ 3.3 V: VOUT(NOM) + 0.5 V ≤ VIN ≤ 6.5 V, IOUT = 1 mA to 500 mA For 1.1 V ≤ VOUT(NOM) < 3.3 V: VOUT(NOM) + 0.5 V ≤ VIN ≤ 6.5 V, IOUT = 1 mA to 500 mA ...
... For VOUT(NOM) ≥ 3.3 V: VOUT(NOM) + 0.5 V ≤ VIN ≤ 6.5 V, IOUT = 1 mA to 500 mA For 1.1 V ≤ VOUT(NOM) < 3.3 V: VOUT(NOM) + 0.5 V ≤ VIN ≤ 6.5 V, IOUT = 1 mA to 500 mA ...
3 3 0 R 1/8 DIN PROCESS MONITOR and
... Loop Power #2 Module) Output Loop Power or Excitation Output + Loop Power or Excitation Output RS-485 Communications + RS-485 Communications Digital Input + Digital Input - ...
... Loop Power #2 Module) Output Loop Power or Excitation Output + Loop Power or Excitation Output RS-485 Communications + RS-485 Communications Digital Input + Digital Input - ...
An Overview of Designing Analog Interface With
... engineers with less exposure to the analog world. Various system consideration issues are discussed, such as setting sampling rate, proper sequencing of input channels for efficient transfer of digital counts to the system’s data memory, inputting the driver/filter circuit, and power supply and cali ...
... engineers with less exposure to the analog world. Various system consideration issues are discussed, such as setting sampling rate, proper sequencing of input channels for efficient transfer of digital counts to the system’s data memory, inputting the driver/filter circuit, and power supply and cali ...
Oscilloscope history
This article discusses the history and development of oscilloscope technology.