Laboratory Exercices for Analog and Digital Circuits
... 5. First, use the multimeter to make sure that potentiometer RL shows a value of 1 kΩ 6. Set the positive variable power supply at approximately 12 V. 7. Using the multimeter, check that the voltage equals that provided by the power supply. 8. Measure the current flowing through RL. Remember that th ...
... 5. First, use the multimeter to make sure that potentiometer RL shows a value of 1 kΩ 6. Set the positive variable power supply at approximately 12 V. 7. Using the multimeter, check that the voltage equals that provided by the power supply. 8. Measure the current flowing through RL. Remember that th ...
TLC3702-Q1 Dual Micropower LinCMOS(TM) Voltage Comparators
... The TLC3702-Q1 contains a digital output stage which, if held in the linear region of the transfer curve, can cause damage to the device. Conventional operational amplifier and comparator testing incorporates the use of a servo loop which is designed to force the device output to a level within this ...
... The TLC3702-Q1 contains a digital output stage which, if held in the linear region of the transfer curve, can cause damage to the device. Conventional operational amplifier and comparator testing incorporates the use of a servo loop which is designed to force the device output to a level within this ...
Voltage differencing transconductance amplifier
... more than one passive element for floating capacitance simulation2-5,7,11,13,15,16. (iii) They use some floating passive components1-2,4,7-9,14. (iv) They employ any external passive resistors1-2,4,7-9,11,13-15. (v) They cannot be tuned electronically1-2, 4, 6-9, 13,14. In recent years, great emphas ...
... more than one passive element for floating capacitance simulation2-5,7,11,13,15,16. (iii) They use some floating passive components1-2,4,7-9,14. (iv) They employ any external passive resistors1-2,4,7-9,11,13-15. (v) They cannot be tuned electronically1-2, 4, 6-9, 13,14. In recent years, great emphas ...
DRV603 数据资料 dataSheet 下载
... ceramic capacitor, typically 1 μF, placed as close as possible to the device VDD lead works best. Placing this decoupling capacitor close to the DRV603 is important for the performance of the amplifier. For filtering lower-frequency noise signals, a 10-μF or greater capacitor placed near the audio p ...
... ceramic capacitor, typically 1 μF, placed as close as possible to the device VDD lead works best. Placing this decoupling capacitor close to the DRV603 is important for the performance of the amplifier. For filtering lower-frequency noise signals, a 10-μF or greater capacitor placed near the audio p ...
pptx
... 2) The time constant of RC circuit may cause reflection 3) In high speed digital design, need to be careful of the capacitor value ...
... 2) The time constant of RC circuit may cause reflection 3) In high speed digital design, need to be careful of the capacitor value ...
Selecting an A/D Converter (Rev. A)
... Not shown in the A/D converter checklist is the most important element in the process: the first step is the complete definition of the design objectives for the digitizing system. The converter checklist can be used as a guideline to insure all important factors are considered. The objective is to ...
... Not shown in the A/D converter checklist is the most important element in the process: the first step is the complete definition of the design objectives for the digitizing system. The converter checklist can be used as a guideline to insure all important factors are considered. The objective is to ...
AD7453 Pseudo Differential, 555 kSPS 12-Bit ADC in an 8
... Inverting Input. This pin sets the ground reference point for the VIN+ input. Connect to ground or to a dc offset to provide a pseudo ground. Analog Ground. Ground reference point for all circuitry on the AD7453. All analog input signals and any external reference signal should be referred to this G ...
... Inverting Input. This pin sets the ground reference point for the VIN+ input. Connect to ground or to a dc offset to provide a pseudo ground. Analog Ground. Ground reference point for all circuitry on the AD7453. All analog input signals and any external reference signal should be referred to this G ...
AD8312 数据手册DataSheet 下载
... were continuous for all values of input. Since this is never the case for a practical log amp, the intercept refers to the value obtained by the minimum-error, straight-line fit to the actual graph of VOUT vs. input power. The quoted values assume a sinusoidal (CW) signal. Where there is complex mod ...
... were continuous for all values of input. Since this is never the case for a practical log amp, the intercept refers to the value obtained by the minimum-error, straight-line fit to the actual graph of VOUT vs. input power. The quoted values assume a sinusoidal (CW) signal. Where there is complex mod ...
Exercise 2 - DMCS Pages for Students
... how to cause the triac to turn on at a desired—and variable—moment. This function must be performed by a separate circuit—the control one. Its task will be to generate pulses of gate current IG that will trigger the triac’s gate and turn it on. An exemplary complete (i.e. including the principal as ...
... how to cause the triac to turn on at a desired—and variable—moment. This function must be performed by a separate circuit—the control one. Its task will be to generate pulses of gate current IG that will trigger the triac’s gate and turn it on. An exemplary complete (i.e. including the principal as ...
LF to 2.5 GHz TruPwr™ Detector AD8361 Data Sheet
... The AD8361 is a mean-responding power detector for use in high frequency receiver and transmitter signal chains, up to 2.5 GHz. It is very easy to apply. It requires a single supply only between 2.7 V and 5.5 V, a power supply decoupling capacitor, and an input coupling capacitor in most application ...
... The AD8361 is a mean-responding power detector for use in high frequency receiver and transmitter signal chains, up to 2.5 GHz. It is very easy to apply. It requires a single supply only between 2.7 V and 5.5 V, a power supply decoupling capacitor, and an input coupling capacitor in most application ...
SSM2166 数据手册DataSheet 下载
... expansion. An integral voltage-controlled amplifier (VCA) provides up to 60 dB of gain in the signal path with approximately 30 kHz bandwidth. Additional gain is provided by an input buffer, op amp circuit that can be set anywhere from 0 dB to 20 dB for a total signal path gain of up to 80 dB. The d ...
... expansion. An integral voltage-controlled amplifier (VCA) provides up to 60 dB of gain in the signal path with approximately 30 kHz bandwidth. Additional gain is provided by an input buffer, op amp circuit that can be set anywhere from 0 dB to 20 dB for a total signal path gain of up to 80 dB. The d ...
High Capacitance MLCCs
... the proper capacitor (low-pass) filtering the supply line. The capacitance should be large enough to absorb any load shift of a device. 3. Smoothing: When AC signals are changed to DC signals, if the voltage waveform contains too much ripple, a capacitor is used to smooth (absorb) this voltage befo ...
... the proper capacitor (low-pass) filtering the supply line. The capacitance should be large enough to absorb any load shift of a device. 3. Smoothing: When AC signals are changed to DC signals, if the voltage waveform contains too much ripple, a capacitor is used to smooth (absorb) this voltage befo ...
Multi Stage Amplifiers
... tuned amplifiers are designed for specific, usually narrow bandwidth but untuned are not designed by such specifications. ...
... tuned amplifiers are designed for specific, usually narrow bandwidth but untuned are not designed by such specifications. ...
MiCOM C264 - Elektronický katalog Schneider Electric
... determines whether the C264 device is blocked or the system just issues a warning. Waveform Recording The MiCOM C264 provides two types of waveform recording: • Fast Waveform Record (FWR), which stores samples at maximum sampling frequency • Slow Waveform Record (SWR), which stores RMS measurements ...
... determines whether the C264 device is blocked or the system just issues a warning. Waveform Recording The MiCOM C264 provides two types of waveform recording: • Fast Waveform Record (FWR), which stores samples at maximum sampling frequency • Slow Waveform Record (SWR), which stores RMS measurements ...
AD8361 数据手册DataSheet 下载
... The AD8361 is an rms-responding (mean power) detector that provides an approach to the exact measurement of RF power that is basically independent of waveform. It achieves this function through the use of a proprietary technique in which the outputs of two identical squaring cells are balanced by th ...
... The AD8361 is an rms-responding (mean power) detector that provides an approach to the exact measurement of RF power that is basically independent of waveform. It achieves this function through the use of a proprietary technique in which the outputs of two identical squaring cells are balanced by th ...
Oscilloscope history
This article discusses the history and development of oscilloscope technology.