• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Measuring Power regulated by Zero Crossing SCR
Measuring Power regulated by Zero Crossing SCR

... The results are displayed on the attached 15 graphs (Not included with this paper. Please contact Ohio Semitronics, Inc. if you want copies of the graphs.) The upper graph depicts the output from the PC5-7EA. The lower graph depicts the output from the PC5-8E. In all cases the averaging filter on th ...
S8VK-G (15/30/60/120/240/480-W Models)
S8VK-G (15/30/60/120/240/480-W Models)

... *1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *2. For a cold start at 25°C. Refer to Engineering Data on page 11 for details. *3. If ...
Auto transformer
Auto transformer

... and secondary windings. This can prove to be dangerous for high voltage applications. • It posses a low impedance, hence if the secondary circuit is short circuited, then a large current will flow on the secondary side. • If The common Part of CB The winding (windingCB) breaks (open Circuit) Then Th ...
Lecture10 MOS Transistor Circuit Analysis
Lecture10 MOS Transistor Circuit Analysis

... For more accurate analyses of FET transistor we have to add more components to an equivalent circuit. Small capacitance: for high response FET amplifiers Drain resistor: account for the effect of vDS on the drain current ...
RLC Circuits Note
RLC Circuits Note

Gas-insulated switchgear up to 420 kV, 63 kA, 5000 A
Gas-insulated switchgear up to 420 kV, 63 kA, 5000 A

... The pressurized gas inside the enclosure in combination with the film insulation provides insulation against high voltage. The high-voltage connection to the switchgear is established via the primary conductor, which is supported by a gas-tight bushing. The secondary connections are routed via a gas ...
wf_meyer_aaron_qiman13 - Aron Qimaan13 Replica of Stan
wf_meyer_aaron_qiman13 - Aron Qimaan13 Replica of Stan

... - comment 1 by qiman13 (http://youtube.com/user/qiman13) : wiring shown may not be like this but if you have a bifilar choke, you can always switch wiring. one point Meyer says 11.6k ohms per choke... that is about 4500 feet long or more of 44 awg wire.. X 2 is a lot of wire. so make sure you build ...
Service manual_VGD
Service manual_VGD

... 2. Dangerous voltage exists at several points in this product. To avoid personal injury, don't touch any exposed connections or components while power is on. 3. Turn off the UPS and disconnect input power cord and two battery cables before removing outside protective cover. 4. AC voltage is always p ...
A+ Guide to Hardware
A+ Guide to Hardware

... – Turn off PC, open computer case, set new power supply on top of the old one – Disconnect old power supply’s cords, plug PC devices into the new power supply – Turn on PC, verify new power supply solves problem A+ Guide to Hardware ...
All amplifiers are analogue, but some amplifiers are more
All amplifiers are analogue, but some amplifiers are more

... are rather more than philosophical. Since power stages and the necessary LC-output-filter deal with currents, voltages and time, they are profoundly analogue. Figure 1(a) shows a series of data bits and one valid way of representing them electrically. Figure 1(b) shows the same signal integrated by ...
Electrical Wheel Chair C.Adhok shaja, E.Rakesh Kumar, K.Nagarjun
Electrical Wheel Chair C.Adhok shaja, E.Rakesh Kumar, K.Nagarjun

... to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being maximum power point tracking. The average value of voltage (and current) fed to the load is controlled by turning ...
RF3930D 10W GaN ON S C POWER AMPLIFIER DIE Features
RF3930D 10W GaN ON S C POWER AMPLIFIER DIE Features

... The physical structure of the GaN HEMT results in three terminal capacitors similar to other FET technologies. These capacitances exist across all three terminals of the device. The physical manufactured characteristics of the device determine the value of the CDS (drain to source), CGS (gate to sou ...
TR41.9.2-04-05-012-MR1-OPS-voltage
TR41.9.2-04-05-012-MR1-OPS-voltage

... NOTICE: The contributor grants a free, irrevocable license to the Telecommunications Industry Association (TIA) to incorporate text or other copyrightable material contained in this contribution and any modifications thereof in the creation of a TIA Publication; to copyright and sell in TIA's name a ...
RT6254A, RT6254B - Richtek Technology
RT6254A, RT6254B - Richtek Technology

... inductance, RMS current rating and, saturation current rating. The inductance selection is generally flexible and is optimized for the low cost, low physical size, and high system performance. Choosing lower inductance to reduce physical size and cost, and it is useful to improve the transient respo ...
BD9610AMUV
BD9610AMUV

... Synchronization occurs on the series three rising edges of the SYNC signal. The clock frequency at the SYNC pin replaces the master clock generated by the oscillator circuit. Pulling the SYNC pin low programs the BD961A0MUV to freely run at the frequency programmed by RRT. ◆Input wave conditions int ...


SIMTRA Training Presentation
SIMTRA Training Presentation

AN-7502 Power MOSFET Switching Waveforms: A New
AN-7502 Power MOSFET Switching Waveforms: A New

... are shown to be valid only for zero drain current. For cases where the gate drive is a voltage step generator with internal fixed resistance, the drain voltage characteristics are inferred from the gate current drive behavior and compared to observed waveforms. The nature of the “asymmetric switchin ...
PDF VERSION click here
PDF VERSION click here

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... REGULATOR ...
SLUS746 120-V Boot, 3-A Peak, High Frequency, High
SLUS746 120-V Boot, 3-A Peak, High Frequency, High

Manual - Robot Marketplace
Manual - Robot Marketplace

... the MOSFETS used are rated at 60 amps continuous with a case temperature of 25°C. As the MOSFETs warm up their allowable current reduces so that at a case temperature of 100 they can (only!) handle 45 amps continuous. The current limiting used in 4QD’s controllers senses the MOSFET temperature and a ...
Power balance and choice of power supply solutions
Power balance and choice of power supply solutions

CN-0081 利用电流源DAC AD5410提供12位、4 mA至20 mA输出简化解决方案
CN-0081 利用电流源DAC AD5410提供12位、4 mA至20 mA输出简化解决方案

4-20mA Current Transmitters with Sensor Excitation and Linearization
4-20mA Current Transmitters with Sensor Excitation and Linearization

< 1 ... 944 945 946 947 948 949 950 951 952 ... 2014 >

Alternating current



Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report