AP1115 Description Pin Assignments
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Portable Sensing Field Device: Noncontact Ranging
... The TDC unit is capable of measuring up to 4 hits on each STOP channel in reference to the START channel; however the ALU can be programmed to find the time differences with reference to any hit on any channel. The ALU retrieves the information from the raw data of the TDC and then, based on the val ...
... The TDC unit is capable of measuring up to 4 hits on each STOP channel in reference to the START channel; however the ALU can be programmed to find the time differences with reference to any hit on any channel. The ALU retrieves the information from the raw data of the TDC and then, based on the val ...
magnetic toroidal cores exposed to a strong stationary magnetic field
... The volume of cylindrically shaped, axially magnetized magnets which create flux density of B = 0.1 T at the distance of 5 mm from their face, has changed in last 20 years from 20 cm3 to 0.3 cm3 [5]. Therefore, the values of magnetic field strenght in surrounding of a typical N dF eB and hard ferrit ...
... The volume of cylindrically shaped, axially magnetized magnets which create flux density of B = 0.1 T at the distance of 5 mm from their face, has changed in last 20 years from 20 cm3 to 0.3 cm3 [5]. Therefore, the values of magnetic field strenght in surrounding of a typical N dF eB and hard ferrit ...
580393681ADM3202_22_1385_c.pdf
... enhancements, and improvements of the AD230–AD241 family and derivatives. They are essentially plug-in-compatible and do not have any materially different applications. ...
... enhancements, and improvements of the AD230–AD241 family and derivatives. They are essentially plug-in-compatible and do not have any materially different applications. ...
Engineering Fundamentals and Problem Solving, 6e
... • A node is a specific point or location within a circuit where two or more components are connected. • A branch is a path that connects two nodes. • A mesh is a loop that does not contain any other loops within itself. • Mesh currents Exist only in the perimeter of the mesh Selected clockwise f ...
... • A node is a specific point or location within a circuit where two or more components are connected. • A branch is a path that connects two nodes. • A mesh is a loop that does not contain any other loops within itself. • Mesh currents Exist only in the perimeter of the mesh Selected clockwise f ...
DIGITAL AC POWER MONITOR DSP- OSI
... THREE-PHASE, THREE-WIRE SYSTEM (TWO CURRENT TRANSFORMERS) NOTE 1: Connection of device voltage neutral to system neutral is recommended but not required. In this configuration, all three phase currents are measured and individual phase power is dependent on system voltage balance if neutral is not c ...
... THREE-PHASE, THREE-WIRE SYSTEM (TWO CURRENT TRANSFORMERS) NOTE 1: Connection of device voltage neutral to system neutral is recommended but not required. In this configuration, all three phase currents are measured and individual phase power is dependent on system voltage balance if neutral is not c ...
AD9752 数据手册DataSheet 下载
... specifically optimized for the transmit signal path of communication systems. All of the devices share the same interface options, small outline package and pinout, thus providing an upward or downward component selection path based on performance, resolution and cost. The AD9752 offers exceptional ...
... specifically optimized for the transmit signal path of communication systems. All of the devices share the same interface options, small outline package and pinout, thus providing an upward or downward component selection path based on performance, resolution and cost. The AD9752 offers exceptional ...
Electrical Safety - HCC Learning Web
... Overloads can be divided into two basic groups: Line break and Pilot duty. The line break overload breaks the power to a motor. A pilot duty overload breaks an auxiliary set of contacts connected in the control circuit. ...
... Overloads can be divided into two basic groups: Line break and Pilot duty. The line break overload breaks the power to a motor. A pilot duty overload breaks an auxiliary set of contacts connected in the control circuit. ...
Table of Contents 8.0
... © 2007 UniStar Nuclear Development, LLC. All rights reserved. COPYRIGHT PROTECTED ...
... © 2007 UniStar Nuclear Development, LLC. All rights reserved. COPYRIGHT PROTECTED ...
PPS3210 Programmable DC Power Supply User`s Manual
... the output current could be up to 5A. However, if the output voltage is set to 3V, the output current will still keep within 5A because of the maximum output current limit. 2. Digital rotary, number key, function key setting: The rotary can be used to change the output voltage rapidly. Simulate the ...
... the output current could be up to 5A. However, if the output voltage is set to 3V, the output current will still keep within 5A because of the maximum output current limit. 2. Digital rotary, number key, function key setting: The rotary can be used to change the output voltage rapidly. Simulate the ...
Capacitors
... Two capacitors, C1 = 2.2 μF and C2 = 1.2 μF, are connected in parallel to a 24-V source as shown. After they are charged they are disconnected from the source and from each other and then reconnected directly to each other, with plates of opposite sign connected together. Find the charge on each cap ...
... Two capacitors, C1 = 2.2 μF and C2 = 1.2 μF, are connected in parallel to a 24-V source as shown. After they are charged they are disconnected from the source and from each other and then reconnected directly to each other, with plates of opposite sign connected together. Find the charge on each cap ...
n60_spec - GE Grid Solutions
... be trip rated Form-A with current and voltage circuit monitors, Form-C, or Fast Form-C for signaling. Hardware input/output capability shall be expandable. The relay shall have three communications ports that operate independently and simultaneously. The RS232 port shall be accessible from the facep ...
... be trip rated Form-A with current and voltage circuit monitors, Form-C, or Fast Form-C for signaling. Hardware input/output capability shall be expandable. The relay shall have three communications ports that operate independently and simultaneously. The RS232 port shall be accessible from the facep ...
SC900 Manual
... The drive is capable of direct line operation. All units are fully isolated and do not require external isolation transformers. Also, the inrush current on the connection to the line is internally limited to a safe level for the drive. There are no voltage selection or ranging switches required to o ...
... The drive is capable of direct line operation. All units are fully isolated and do not require external isolation transformers. Also, the inrush current on the connection to the line is internally limited to a safe level for the drive. There are no voltage selection or ranging switches required to o ...
Computer interfacing Introduction
... Slew rate -- the maximum rate of output change (V/us) for a large input step change. ...
... Slew rate -- the maximum rate of output change (V/us) for a large input step change. ...
LM34 Precision Fahrenheit Temperature Sensors
... sensors, whose output voltage is linearly proportional to the Fahrenheit temperature. The LM34 thus has an advantage over linear temperature sensors calibrated in degrees Kelvin, as the user is not required to subtract a large constant voltage from its output to obtain convenient Fahrenheit scaling. ...
... sensors, whose output voltage is linearly proportional to the Fahrenheit temperature. The LM34 thus has an advantage over linear temperature sensors calibrated in degrees Kelvin, as the user is not required to subtract a large constant voltage from its output to obtain convenient Fahrenheit scaling. ...
THE ELECTRONIC SYSTEM DESIGN, ANALYSIS, INTEGRATION
... improve efficiency, for loads less than 150mW, the 5V converter is configured for Pulse Frequency Modulation (PFM) Mode. With loads greater than 150mW, the 3.6V converters operate most efficiently in Pulse Width Modulation (PWM) Mode. ...
... improve efficiency, for loads less than 150mW, the 5V converter is configured for Pulse Frequency Modulation (PFM) Mode. With loads greater than 150mW, the 3.6V converters operate most efficiently in Pulse Width Modulation (PWM) Mode. ...
AN1772
... without the correct power supply voltage. Every microprocessor needs its power supply to be within a predefined range, to be able to function properly. A small glitch in the power supply can cause the system to crash. Incorrect power-up sequences, slow ramp-up and glitches on the supply lines are co ...
... without the correct power supply voltage. Every microprocessor needs its power supply to be within a predefined range, to be able to function properly. A small glitch in the power supply can cause the system to crash. Incorrect power-up sequences, slow ramp-up and glitches on the supply lines are co ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).