Multifunction Data Acquisition USB Module USB2AD
... Since the DMM is powered via a USB cable, it is important to make sure it gets the required 5V supply. Using the right USB cable is very important. Make sure this cable has a 24 AWG wires for power supply, indicated by marking on the cable such as <28/1P + 24/2C>. Be aware that there are a lot of ca ...
... Since the DMM is powered via a USB cable, it is important to make sure it gets the required 5V supply. Using the right USB cable is very important. Make sure this cable has a 24 AWG wires for power supply, indicated by marking on the cable such as <28/1P + 24/2C>. Be aware that there are a lot of ca ...
GE Controls | Installation Guide | Centralized Lighting Control Panel
... 4. Connect dataline switch(s) and/or dataline scheduler to the CLCGSM8/CLCPIM using CAT5 or higher UTP 4 pair 24AWG cable. The connection should start from the CLCGSM8/CLCPIM “PWR/NET OUT connection” and connect to the “IN” of the next device. Proceed from the “OUT” of that device in a daisy chain f ...
... 4. Connect dataline switch(s) and/or dataline scheduler to the CLCGSM8/CLCPIM using CAT5 or higher UTP 4 pair 24AWG cable. The connection should start from the CLCGSM8/CLCPIM “PWR/NET OUT connection” and connect to the “IN” of the next device. Proceed from the “OUT” of that device in a daisy chain f ...
BDTIC www.BDTIC.com/infineon Distribution Training „Going for a
... cooling fan applications Copyright © Infineon Technologies 2011. All rights reserved. ...
... cooling fan applications Copyright © Infineon Technologies 2011. All rights reserved. ...
World in motion
... the amplifiers, the LV controllers offer the unique power of the Delta Tau position control systems. This concept provides great savings in both panel space and installation costs and whilst the design is optimised for operation using a 48VDC bus - a level that eliminates many regulatory concerns – ...
... the amplifiers, the LV controllers offer the unique power of the Delta Tau position control systems. This concept provides great savings in both panel space and installation costs and whilst the design is optimised for operation using a 48VDC bus - a level that eliminates many regulatory concerns – ...
ZXTC6717MC Features Mechanical Data
... 6. For a dual device surface mounted on 28mm x 28mm (8cm2) FR4 PCB with high coverage of single sided 2 oz copper, in still air conditions; the device is measured when operating in a steady-state condition. The heatsink is split in half with the exposed collector pads connected to each half. 7. Same ...
... 6. For a dual device surface mounted on 28mm x 28mm (8cm2) FR4 PCB with high coverage of single sided 2 oz copper, in still air conditions; the device is measured when operating in a steady-state condition. The heatsink is split in half with the exposed collector pads connected to each half. 7. Same ...
Hysteresis Brake and Clutch user`s manual.
... Magtrol Hysteresis Brakes will perform equally well regardless of physical orientation. A solid double extended through-shaft is provided to facilitate coupling to either side of the brake. Because the brake employs a rotating element on one end (drag cup or rotor), surface mounting of the brake is ...
... Magtrol Hysteresis Brakes will perform equally well regardless of physical orientation. A solid double extended through-shaft is provided to facilitate coupling to either side of the brake. Because the brake employs a rotating element on one end (drag cup or rotor), surface mounting of the brake is ...
VFD
... A VFD provides a smooth start by ramping up motor speed. This helps eliminate shock on mechanical components: Couplings Gearboxes Pumping systems. Filter out natural frequency of a mechanical system on startup. Provide overload protections. Provide single phasing protection. Helps re ...
... A VFD provides a smooth start by ramping up motor speed. This helps eliminate shock on mechanical components: Couplings Gearboxes Pumping systems. Filter out natural frequency of a mechanical system on startup. Provide overload protections. Provide single phasing protection. Helps re ...
AN2323
... multiplier window, as shown in Figure 10. These values are those provided by the phantom load equipment and are also shown in Table 5 above. One multiplier factor should be taken at a time. Read the offsets by clicking on the Read icon. After taking a set of readings, click on the Write icon. After ...
... multiplier window, as shown in Figure 10. These values are those provided by the phantom load equipment and are also shown in Table 5 above. One multiplier factor should be taken at a time. Read the offsets by clicking on the Read icon. After taking a set of readings, click on the Write icon. After ...
ADCMP582 数据手册DataSheet 下载
... The CML output stage is designed to directly drive 400 mV into 50 Ω transmission lines terminated to ground. The NECL output stages are designed to directly drive 400 mV into 50 Ω terminated to −2 V. The PECL output stages are designed to directly drive 400 mV into 50 Ω terminated to VCCO − 2 V. Hig ...
... The CML output stage is designed to directly drive 400 mV into 50 Ω transmission lines terminated to ground. The NECL output stages are designed to directly drive 400 mV into 50 Ω terminated to −2 V. The PECL output stages are designed to directly drive 400 mV into 50 Ω terminated to VCCO − 2 V. Hig ...
Vcc + Vss - Renesas E
... • Technique for reducing common-mode emissions from PCB supply lines by achieving balanced impedances • Application of the CM noise reduction-method to the package for a microcontroller • Tests showing the effectiveness of the technique for reducing common-mode noise ...
... • Technique for reducing common-mode emissions from PCB supply lines by achieving balanced impedances • Application of the CM noise reduction-method to the package for a microcontroller • Tests showing the effectiveness of the technique for reducing common-mode noise ...
Contents - Metravi
... (2) Refer to the desiring for the power. Move the line voltage converter to the “correct” position. (3) Connect power cable to the AC input. · Insure that the fuse used is an authorized product. In order to prevent circuit damage resulting from over current, use the correct fuse value for the primar ...
... (2) Refer to the desiring for the power. Move the line voltage converter to the “correct” position. (3) Connect power cable to the AC input. · Insure that the fuse used is an authorized product. In order to prevent circuit damage resulting from over current, use the correct fuse value for the primar ...
MAX4721 DS
... UCSP parts are 100% tested at +25°C only, and guaranteed by design over the specified temperature range. µMAX parts are 100% tested at TMAX and guaranteed by design over the specified temperature range. Note 4: The algebraic convention used in this data sheet is where the most negative value is a mi ...
... UCSP parts are 100% tested at +25°C only, and guaranteed by design over the specified temperature range. µMAX parts are 100% tested at TMAX and guaranteed by design over the specified temperature range. Note 4: The algebraic convention used in this data sheet is where the most negative value is a mi ...
1.5-Gbps LVDS/LVPECL/CML-to
... tsk(p) is the magnitude of the time difference between the tPLH and tPHL. tsk(pp) is the magnitude of the difference in propagation delay times between any specified terminals of two devices when both devicesoperate with the same supply voltages, at the same temperature, and have identical packages ...
... tsk(p) is the magnitude of the time difference between the tPLH and tPHL. tsk(pp) is the magnitude of the difference in propagation delay times between any specified terminals of two devices when both devicesoperate with the same supply voltages, at the same temperature, and have identical packages ...
FPGA-Based Control for Electric Vehicle and Hybrid Electric
... Simplified Power Control Architecture for a Hybrid EV Figure 2 shows a common hybrid EV architecture that utilizes two independent motor or generators (MG) connected electrically through a DC link. The DC link is also connected to a 250 V battery though a VVC or bidirectional DC-DC converter compris ...
... Simplified Power Control Architecture for a Hybrid EV Figure 2 shows a common hybrid EV architecture that utilizes two independent motor or generators (MG) connected electrically through a DC link. The DC link is also connected to a 250 V battery though a VVC or bidirectional DC-DC converter compris ...
PBSS4160U 1. Product profile 60 V, 1 A NPN low V
... therefore such inclusion and/or use is at the customer’s own risk. Applications — Applications that are described herein for any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use ...
... therefore such inclusion and/or use is at the customer’s own risk. Applications — Applications that are described herein for any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use ...
final project report ee3390 electronic circuits design lab power inverter
... poles in its feedback however this makes the circuit extremely sensitive to changes in phase. ...
... poles in its feedback however this makes the circuit extremely sensitive to changes in phase. ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).