x - Network and Systems Lab
... VP1.1 = 0 Current flow through, turn on the LED GPIO can use as an On/Off control ...
... VP1.1 = 0 Current flow through, turn on the LED GPIO can use as an On/Off control ...
lesson topic 8.1 synchros and control
... one direction during onehalf cycle (view A) and in the other direction during the next half cycle (view B). Because of its inertia, the bar magnet cannot turn rapidly enough to follow the changing magnetic field and may line up with either end toward the coil (view C). ...
... one direction during onehalf cycle (view A) and in the other direction during the next half cycle (view B). Because of its inertia, the bar magnet cannot turn rapidly enough to follow the changing magnetic field and may line up with either end toward the coil (view C). ...
Hall Effect Devices
... Calibration was a matter of applying a voltage with a load of a known current (1 Amp, 2 Amps and 3 Amps) and measuring the change in output voltage of the A1302E. It works. Not great design or a design of grace and beauty, but it worked. There are a few advantages of the design over using a resisto ...
... Calibration was a matter of applying a voltage with a load of a known current (1 Amp, 2 Amps and 3 Amps) and measuring the change in output voltage of the A1302E. It works. Not great design or a design of grace and beauty, but it worked. There are a few advantages of the design over using a resisto ...
New techniques for inverter flux control
... vector is chosen when the error magnitude becomes less than a specified tolerance. An active vector is chosen if the error magnitude exceeds the tolerance. The strategy for choosing the active vector is reported to reduce the number of switchings per output cycle compared to the “fish” method of [6] ...
... vector is chosen when the error magnitude becomes less than a specified tolerance. An active vector is chosen if the error magnitude exceeds the tolerance. The strategy for choosing the active vector is reported to reduce the number of switchings per output cycle compared to the “fish” method of [6] ...
THE DETROIT EDISON COMPANY
... The rates and charges under this tariff are based on the customer maintaining a power factor of not less than 85% lagging. Any power factor less than 70% will not be permitted and the customer will be required to install at his own expense such corrective equipment as may be necessary to improve pow ...
... The rates and charges under this tariff are based on the customer maintaining a power factor of not less than 85% lagging. Any power factor less than 70% will not be permitted and the customer will be required to install at his own expense such corrective equipment as may be necessary to improve pow ...
Electrical Supplies
... • Power indicator light goes off if GFCI trips or unit is unplugged • Wiring module accepts No. 18 and No. 12 cord sizes • Electronics housing and wiring terminal chamber specially sealed to protect from moisture and dust • UL recognized and CSA certified See technical bulletin from NAMA Make sure y ...
... • Power indicator light goes off if GFCI trips or unit is unplugged • Wiring module accepts No. 18 and No. 12 cord sizes • Electronics housing and wiring terminal chamber specially sealed to protect from moisture and dust • UL recognized and CSA certified See technical bulletin from NAMA Make sure y ...
A Mathematical Descr..
... Likewise, from KCL, we can determine the emitter current for a BJT in the ACTIVE mode: iE iC iB iB iB 1 iB ...
... Likewise, from KCL, we can determine the emitter current for a BJT in the ACTIVE mode: iE iC iB iB iB 1 iB ...
Medium Voltage MCC Guide Specification
... ground the transformer primary windings and the fuses. A visible indication of positive ground is required. The ground may be a momentary or sweeping action that occurs as the unit moved out of the connected position. ...
... ground the transformer primary windings and the fuses. A visible indication of positive ground is required. The ground may be a momentary or sweeping action that occurs as the unit moved out of the connected position. ...
Totem Kin Subwoofer User Manual - ATEM Hi-Fi
... When using the Totem subwoofer in a stereo setup its ideal location between the main speakers or right beside them. When the Totem subwoofer is used in a home cinema system it is recommended to place it in a corner. Be careful not to place the subwoofer too close to the corner, or it will start to s ...
... When using the Totem subwoofer in a stereo setup its ideal location between the main speakers or right beside them. When the Totem subwoofer is used in a home cinema system it is recommended to place it in a corner. Be careful not to place the subwoofer too close to the corner, or it will start to s ...
arch_spec_SolaMaster_330DS
... inch (51 mm) clearance between flashing and rib: Type FSM. Aluminum 1060 Alloy, corrosion resistant conforming to ASTM B 209, 0.059 inch (1.5 mm) thick. 3. Flashing Insulator: Type FI, Thermal isolation material for use under the following flashing types; Type F4, F8, or F11. 4. Curb Insulator: Type ...
... inch (51 mm) clearance between flashing and rib: Type FSM. Aluminum 1060 Alloy, corrosion resistant conforming to ASTM B 209, 0.059 inch (1.5 mm) thick. 3. Flashing Insulator: Type FI, Thermal isolation material for use under the following flashing types; Type F4, F8, or F11. 4. Curb Insulator: Type ...
Application notes
... Limit indication (e.g. indicator for too low a water level in the reservoir for the windshield wipers) ...
... Limit indication (e.g. indicator for too low a water level in the reservoir for the windshield wipers) ...
Integrated fluorescent-incandescent lamp assembly
... the serially connected ?lament loop comprised of ?la~ ment f1, glow switch 26, ?lament f2 and incandescent bulb is attached to the base plate as is an incandescent ballast ?lament f3. bulb, the latter being positioned between the legs of the Initially the current will be low due to the high impe ?uo ...
... the serially connected ?lament loop comprised of ?la~ ment f1, glow switch 26, ?lament f2 and incandescent bulb is attached to the base plate as is an incandescent ballast ?lament f3. bulb, the latter being positioned between the legs of the Initially the current will be low due to the high impe ?uo ...
Meter Design for Power Failure Events
... TERIDIAN’s demonstration code return to normal operation. Code should not reset or permanently disable metering due to a sag event, because this causes loss of revenue. In order for the code to recover, all the routines called from the interrupt that detects the sag event have to be reentrant. In pa ...
... TERIDIAN’s demonstration code return to normal operation. Code should not reset or permanently disable metering due to a sag event, because this causes loss of revenue. In order for the code to recover, all the routines called from the interrupt that detects the sag event have to be reentrant. In pa ...
Folha de dados do detector de duto para ar
... The LRS 03 is approved by the Deutsches Institut für Bautechnik (DIBt) supervisory authority and can be used to activate fire and smoke protection dampers. The following equipment is also required for use in accordance with the approval notification for activating fire and smoke protection dampers: ...
... The LRS 03 is approved by the Deutsches Institut für Bautechnik (DIBt) supervisory authority and can be used to activate fire and smoke protection dampers. The following equipment is also required for use in accordance with the approval notification for activating fire and smoke protection dampers: ...
MicroSet Ultrasonic Low Voltage Ceiling Sensor Installation Instructions - English
... Half Logic Mode – the output state of the yellow control lead will not change with ambient light changes, after occupancy activation. If the amount of natural light available rises above the setpoint, the daylight sensor will not turn the lights OFF while occupancy is being detected. Note: Set the l ...
... Half Logic Mode – the output state of the yellow control lead will not change with ambient light changes, after occupancy activation. If the amount of natural light available rises above the setpoint, the daylight sensor will not turn the lights OFF while occupancy is being detected. Note: Set the l ...
UCC29950 CCM PFC and LLC Combo Controller
... resistor from the rectified AC line to VCC is typically used. As a result standby power consumption is reduced. Connect the FET gate to SUFG and its source to SUFS. The drain of the FET is connected to the rectified AC voltage. SUFG and SUFS control the initial charging of the capacitor on the VCC r ...
... resistor from the rectified AC line to VCC is typically used. As a result standby power consumption is reduced. Connect the FET gate to SUFG and its source to SUFS. The drain of the FET is connected to the rectified AC voltage. SUFG and SUFS control the initial charging of the capacitor on the VCC r ...
Overview of Charge Time Measurement Unit (CTMU)
... Welcome to the “Overview of Charge Time Measurement Unit” Webinar. My name is Padmaraja Yedamale, I am an applications engineer working in Advanced Microcontroller and Architecture Division at Microchip Technology. In this webinar I am going to explain the new peripheral on PIC microcontrollers call ...
... Welcome to the “Overview of Charge Time Measurement Unit” Webinar. My name is Padmaraja Yedamale, I am an applications engineer working in Advanced Microcontroller and Architecture Division at Microchip Technology. In this webinar I am going to explain the new peripheral on PIC microcontrollers call ...
Detection of Stator Short Circuit Faults in Three-Phase
... open-circuit of the stator coil which is out of scope of this paper. Several studies [5, 6, 9, 10, 11, 12, 19, 20] report that depending on the type of shorts, and condition of motor (age, working condition, etc), the motor may continue to operate initially, even though short-circuit current will fl ...
... open-circuit of the stator coil which is out of scope of this paper. Several studies [5, 6, 9, 10, 11, 12, 19, 20] report that depending on the type of shorts, and condition of motor (age, working condition, etc), the motor may continue to operate initially, even though short-circuit current will fl ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).