MAX1178/MAX1188 16-Bit, 135ksps, Single-Supply ADCs with Bipolar Analog Input Range General Description
... The MAX1178/MAX1188 16-bit, low-power, successiveapproximation analog-to-digital converters (ADCs) feature automatic power-down, a factory-trimmed internal clock, and a byte-wide parallel interface. The devices operate from a single +4.75V to +5.25V analog supply and feature a separate digital suppl ...
... The MAX1178/MAX1188 16-bit, low-power, successiveapproximation analog-to-digital converters (ADCs) feature automatic power-down, a factory-trimmed internal clock, and a byte-wide parallel interface. The devices operate from a single +4.75V to +5.25V analog supply and feature a separate digital suppl ...
26 13 16 Medium-voltage fusible interrupter switchgear (air
... switches, busbar, grounding switches, VTs, etc.) shall be in grounded metal enclosures. The construction shall withstand forces (repeatedly, without distortion) caused by closing and opening of the load interrupter switch. The switchgear shall be capable of sustaining, without damage, all of the str ...
... switches, busbar, grounding switches, VTs, etc.) shall be in grounded metal enclosures. The construction shall withstand forces (repeatedly, without distortion) caused by closing and opening of the load interrupter switch. The switchgear shall be capable of sustaining, without damage, all of the str ...
MAX13234E–MAX13237E 3Mbps RS-232 Transceivers with Low-Voltage Interface General Description
... loads of 3kΩ in parallel with 150pF. Transmitters can be paralleled to drive multiple receivers. When FORCEOFF is driven to ground or when the AutoShutdown Plus circuitry senses that all receiver and transmitter inputs are inactive for more than 30s, the transmitters are disabled and the outputs go ...
... loads of 3kΩ in parallel with 150pF. Transmitters can be paralleled to drive multiple receivers. When FORCEOFF is driven to ground or when the AutoShutdown Plus circuitry senses that all receiver and transmitter inputs are inactive for more than 30s, the transmitters are disabled and the outputs go ...
Installation and Owner`s Manual Air-cooled, Prepackaged
... the generator to be connected to an approved earth ground. Local electrical codes also may require proper grounding of the generator electrical system. • After installing this home standby electrical system, the generator may crank and start at any time without warning. When this occurs, load circui ...
... the generator to be connected to an approved earth ground. Local electrical codes also may require proper grounding of the generator electrical system. • After installing this home standby electrical system, the generator may crank and start at any time without warning. When this occurs, load circui ...
The Secrets of UL and NFPA. - Automation Technology
... Branch circuit protection: Overcurrent protection with an ampere rating selected to protect the branch circuit (devices and cables). For a motor branch circuit, the overcurrent protection is required for overcurrents due to short circuits and faults to ground only. ...
... Branch circuit protection: Overcurrent protection with an ampere rating selected to protect the branch circuit (devices and cables). For a motor branch circuit, the overcurrent protection is required for overcurrents due to short circuits and faults to ground only. ...
MAX5389 Evaluation Kit Evaluates: General Description Features
... and JU9 for potentiometer A and jumpers JU10 and JU11 for potentiometer B configuration. Tables 4 and 5 list the jumper options for configuring potentiometers A and B. The MAX5389 can also be configured as a variable resistor by shorting the H_ and W_ pads using a wire. When operating as a variable ...
... and JU9 for potentiometer A and jumpers JU10 and JU11 for potentiometer B configuration. Tables 4 and 5 list the jumper options for configuring potentiometers A and B. The MAX5389 can also be configured as a variable resistor by shorting the H_ and W_ pads using a wire. When operating as a variable ...
MAX1425 10-Bit, 20Msps ADC General Description Features
... The MAX1425 employs a differential pipelined architecture with a wideband T/H amplifier to maximize throughput while limiting power consumption to only 172mW. The MAX1425 generates an internal +2.5V reference that supplies three additional reference voltages (+3.25V, +2.25V, and +1.25V). These refer ...
... The MAX1425 employs a differential pipelined architecture with a wideband T/H amplifier to maximize throughput while limiting power consumption to only 172mW. The MAX1425 generates an internal +2.5V reference that supplies three additional reference voltages (+3.25V, +2.25V, and +1.25V). These refer ...
Liebert PPC Two Stage Distribution 150-800kVA Guide
... and the emission and immunity limits of EN50081-2/EN550022 Class A and EN50082-2. The system shall safely withstand without misoperation or damage: Transient voltage surges on the AC power input as defined by ANSI/IEEE C62.41 for Category B3 locations (high surge exposure industrial and commercial ...
... and the emission and immunity limits of EN50081-2/EN550022 Class A and EN50082-2. The system shall safely withstand without misoperation or damage: Transient voltage surges on the AC power input as defined by ANSI/IEEE C62.41 for Category B3 locations (high surge exposure industrial and commercial ...
Hardware Manual - RTD Embedded Technologies, Inc.
... Charger power converter ......................................................................................................................................... 23 Ni-Mh/Ni-CD Battery Pack and Thermistor ............................................................................................... ...
... Charger power converter ......................................................................................................................................... 23 Ni-Mh/Ni-CD Battery Pack and Thermistor ............................................................................................... ...
Manufactures
... (elbow, tees, end Cable Tap Box, etc.) shall be in accordance to IEC 60439:2005 and from the same manufacturer as the busbar trunking system. 2. All contact on joint and plug-in opening should be silver plating copper to avoid electrochemical corrosion and minimizes the contact resistance 3. Rated o ...
... (elbow, tees, end Cable Tap Box, etc.) shall be in accordance to IEC 60439:2005 and from the same manufacturer as the busbar trunking system. 2. All contact on joint and plug-in opening should be silver plating copper to avoid electrochemical corrosion and minimizes the contact resistance 3. Rated o ...
Magnetic Saturation Effect of the Iron Core in Current Transformers
... in which the induced electromotive force was generated was regarded as a winding using the variation of the electric scalar potential as a constraint condition. To express the surge current as a function, the amplitude of the frequency harmonics was extracted through the development of the 8/20 μs w ...
... in which the induced electromotive force was generated was regarded as a winding using the variation of the electric scalar potential as a constraint condition. To express the surge current as a function, the amplitude of the frequency harmonics was extracted through the development of the 8/20 μs w ...
FZT558 Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
NX-PD/PF/PC/TBX
... • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, CE: EC Directives, and KC: KC Registration. • Contact your OMRON representati ...
... • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, CE: EC Directives, and KC: KC Registration. • Contact your OMRON representati ...
UL 508 A Short Circuit Current Rating
... “Listed and Labeled Method” – A Further Look An example based upon the Listed and Labeled method would be submittal of the completed Assembly for third-party compliance testing to the short circuit current requirements of the UL 508A Standard for Industrial Control Panels. If, for example, Underwrit ...
... “Listed and Labeled Method” – A Further Look An example based upon the Listed and Labeled method would be submittal of the completed Assembly for third-party compliance testing to the short circuit current requirements of the UL 508A Standard for Industrial Control Panels. If, for example, Underwrit ...
74LCX573 Low Voltage Octal Latch with 5V Tolerant Inputs and Outputs
... The LCX573 is functionally identical to the LCX373 but has inputs and outputs on opposite sides. The LCX573 is designed for low voltage applications with capability of interfacing to a 5V signal environment. The LCX573 is fabricated with an advanced CMOS tech- nology to achieve high speed operation ...
... The LCX573 is functionally identical to the LCX373 but has inputs and outputs on opposite sides. The LCX573 is designed for low voltage applications with capability of interfacing to a 5V signal environment. The LCX573 is fabricated with an advanced CMOS tech- nology to achieve high speed operation ...
Timers
... Voltage is applied to the coil at all times. When a start signal is supplied, the contacts remain in the off state and the set time begins. At the end of the set time, the contacts transfer to the on state and remain in the on state for the set time. After the set time has elapsed, the contacts retu ...
... Voltage is applied to the coil at all times. When a start signal is supplied, the contacts remain in the off state and the set time begins. At the end of the set time, the contacts transfer to the on state and remain in the on state for the set time. After the set time has elapsed, the contacts retu ...
POWER DISTRIBUTION SUB
... Figure 3.9 Three phase double-tuned filters for 11th and 13th harmonic reduction ....... 42 Figure 3.10 C-type filter diagram .................................................................................... 43 Figure 3.11 Three phase C-type tuned filter for 5th harmonic reduction ............... ...
... Figure 3.9 Three phase double-tuned filters for 11th and 13th harmonic reduction ....... 42 Figure 3.10 C-type filter diagram .................................................................................... 43 Figure 3.11 Three phase C-type tuned filter for 5th harmonic reduction ............... ...
POWERFIELDS www.powerfields.com FENCE
... An electric fence is a less-than-ideal environment on which to conduct electricity. Along the course of the average fence there are many conditions that will divert or impede the flow of electricity. Collectively, these conditions are known as “fence load.” Weeds or vegetation growing on the fence ...
... An electric fence is a less-than-ideal environment on which to conduct electricity. Along the course of the average fence there are many conditions that will divert or impede the flow of electricity. Collectively, these conditions are known as “fence load.” Weeds or vegetation growing on the fence ...
SBR1A40S3 Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).