• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
The Aircraft Magneto
The Aircraft Magneto

... down a spark plug gap in an engine, since the latter process is not one of “drawing” an arc but rather one of puncturing, or breaking down, the layer of gas between the spark plug electrodes. The voltage required to do this may be as high as 12,000 to 15,000 volts under some conditions of engine and ...
MAX2023 DS
MAX2023 DS

Sliding Rheostats
Sliding Rheostats

Parallel Operation and Standby Service Schedule Designation R3
Parallel Operation and Standby Service Schedule Designation R3

... standby contract capacity utilized plus the Rider 3 Generation Reservation Charge times the difference between the total standby contract capacity and the maximum standby utilized. For customers served on supplemental rates schedules D6.2, D8 and D11, the Daily Demand Cap will be determined as the D ...
Chapter 7 - Automation Direct
Chapter 7 - Automation Direct

6200000 GROUNDING AND LIGHTNING PROTECTION COMMENTS FROM INTERNAL/INDUSTRY REVIEW Craig Carnes
6200000 GROUNDING AND LIGHTNING PROTECTION COMMENTS FROM INTERNAL/INDUSTRY REVIEW Craig Carnes

... provided for additional clarification and as supporting information for FDOT requirements. However, prequalification of contractors for signalization and electrical work, as well as Division I content requiring the contractor to be familiar and comply with “…all Federal, State, county, and city laws ...
25 to 600 Watts DC-DC Converters Single, Dual, Triple Output
25 to 600 Watts DC-DC Converters Single, Dual, Triple Output

... This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assum ...
BDTIC www.BDTIC.com/infineon H a r d   C o m m...
BDTIC www.BDTIC.com/infineon H a r d C o m m...

... power density. The breakdown voltage has evolved from sub 20V to 250V for state-of-the-art trench fieldplate Power MOSFETs. In the 200V to 250V medium voltage range, up until now, Infineon has been offering industry leading OptiMOS™ 3 devices with the lowest figure of merit (RDS(on) x Qg). They not ...
Altivar ® 31 Adjustable Speed AC Drives
Altivar ® 31 Adjustable Speed AC Drives

... This kit is used to mount a keypad display remotely, such as on the door of a wall-mounted or floorstanding enclosure. The remote keypad display offers the same features as the drive local keypad display, with the addition of (a) run, stop/reset, and forward/reverse buttons; and (b) an access lockin ...
MAX9248/MAX9250 27-Bit, 2.5MHz to 42MHz DC-Balanced LVDS Deserializers General Description
MAX9248/MAX9250 27-Bit, 2.5MHz to 42MHz DC-Balanced LVDS Deserializers General Description

... The MAX9248/MAX9250 digital video serial-to-parallel converters deserialize a total of 27 bits during data and control phases. In the data phase, the LVDS serial input is converted to 18 bits of parallel video data and in the control phase, the input is converted to 9 bits of parallel control data. ...
LTM4600 - 10A High Efficiency DC/DC uModule
LTM4600 - 10A High Efficiency DC/DC uModule

... Pulling the RUN/SS pin low forces the controller into its shutdown state, turning off both Q1 and Q2. Releasing the pin allows an internal 1.2μA current source to charge up the softstart capacitor. When this voltage reaches 1.5V, the controller turns on and begins switching. At low load current the ...
Passive Infrared Wall/Corner Sensor (OAWC-P-120W OAWC-P-120W-R) Installation Instructions - English
Passive Infrared Wall/Corner Sensor (OAWC-P-120W OAWC-P-120W-R) Installation Instructions - English

... when a person, or part of a person as small as a hand, passes into or out of a sensor zone. The sensor includes self-adaptive technology that continually adjusts to conditions by adjusting sensitivity and time delay in realtime. By adjusting sensitivity and time delay automatically, the sensor is ma ...
by Submitted in partial fulfilment of the requirements for the degree
by Submitted in partial fulfilment of the requirements for the degree

... first temperature interval of 0 to 25 °C is due to the fact that amplitude control is not fully effective, as the oscillation amplitude is still building up. Using the temperature stabilised loop, the overall frequency stability has improved to 16 parts per million (ppm)/°C from an uncompensated val ...
Document
Document

... A2 and A1 = rms complex vector potentials at upper and lower boundaries at the air gap (Fig. 2). LNET = Net stack length with ventilating ducts subtracted, but with the stacking factor disregarded. POLES = Number of poles. Per unit terminal voltage, calculated as a complex number as the air gap volt ...
Technical Overview - home.hs
Technical Overview - home.hs

... operation in the presence of transients and also allows high to low voltage translation via series input resistors. The typical value of ∝ for QMOS ICs is 0.001. Figure 13 illustrates how control of ∝ in QMOS devices provides for safe conversion of 12V control logic levels to 5V HC system logic simp ...
The Fields Outside a Long Solenoid with a Time
The Fields Outside a Long Solenoid with a Time

... r/c. Yet it is clear that for small enough time difference between ct and r the solenoid current appears to the observer as that due only to the portion of the surface nearest the observer. In this limit the effective current is at right angles to the axis of the solenoid and its magnitude is arbitra ...
Amplification of biosignals by body potential driving. Analysis of the
Amplification of biosignals by body potential driving. Analysis of the

... R 2 is the resistor of the BPD frequency compensation circuit. The test voltage E can be a rectangular waveform and at the outputs of all amplifiers with existing electrodeto-skin contact we will obtain these test pulses. Some difficulties arise because the output test voltage is mixed with biopoten ...
EFFICIENT CONTROL OF THE SERIES RESONANT CONVERTER FOR HIGH FREQUENCY OPERATION
EFFICIENT CONTROL OF THE SERIES RESONANT CONVERTER FOR HIGH FREQUENCY OPERATION

... for the many enlightening discussions concerning all areas of power electronics. In particular I’d like to thank Wilson Eberle, Majid Pahlevaninezhad, Ali Khajehoddin, Zhiliang Zhang, Eric Meyer, Pan Shangzhi, John Lam, Mohammad Agamy, and Pritam Das. I would like to acknowledge the efforts of ePOWE ...
FTA200 A Remote Alarm Panels for Electric Fire Pump Controllers Product Description
FTA200 A Remote Alarm Panels for Electric Fire Pump Controllers Product Description

SKY65014-70LF 数据资料DataSheet下载
SKY65014-70LF 数据资料DataSheet下载

... The input and output of the SKY65014-70LF are connected using 50 Ω microstrip transmission lines with DC blocking capacitors, C1 and C2, to the input and output SMA connectors, respectively. The positive supply voltage, VDD, is connected to pin 3 (OUTPUT) of the amplifier using the decoupling networ ...
Ionizer Nozzle type
Ionizer Nozzle type

PHE13003A 1. Product profile NPN power transistor
PHE13003A 1. Product profile NPN power transistor

... malfunction of an NXP Semiconductors product can reasonably be expected to result in personal injury, death or severe property or environmental damage. NXP Semiconductors accepts no liability for inclusion and/or use of NXP Semiconductors products in such equipment or applications and therefore such ...
B0407
B0407

... pins that allow external information flow in and out of the microcontroller. In this lab, you will primarily be concerned with these input/output pins. The six pins labeled A0 through A5 have the analog to digital conversion (ADC) capability. This means that you can measure an analog voltage (betwee ...
1 - Fel Zcu - Západočeská univerzita
1 - Fel Zcu - Západočeská univerzita

... homogenous. However, this system had certain disadvantages as well. Hence the so called “hard” insulation system came. Glass fibre or PET (Poly Ethylene Terephthalate) foil together with reconstructed mica (Bardet or Heyman process [3]) and epoxy-resin are used instead. Three-component composite has ...
Power 2 You - Lattice Semiconductor
Power 2 You - Lattice Semiconductor

... circuit board power management functions shown as 3-D blocks in Figure 1-1 and Figure 1-2. This book also provides generalized cost effective solutions for each of these functions that can be customized to meet a circuit board’s specific voltage, current and control environment. For readers viewing ...
< 1 ... 188 189 190 191 192 193 194 195 196 ... 2014 >

Alternating current



Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report