• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AVOP-ELEKTRO-SKA-006
AVOP-ELEKTRO-SKA-006

... rotary electric machine where it‘s magnetic circuit is divided by the small gap into two parts: the stator and the rotor. Both parts have a winding. One winding (usually on the stator) is connected to the source of the alternating current and the other (usually on the rotor) is connected on short di ...


Science Part B Chapter –4- Electrical Energy Lesson –1
Science Part B Chapter –4- Electrical Energy Lesson –1

3-phase short-circuit current (Isc) at any point within a LV installation
3-phase short-circuit current (Isc) at any point within a LV installation

... In general, this fault-current contribution may be ignored. However, if the total power of motors running simultaneously is higher than 25% of the total power o Their total contribution can be estimated from the formula: Iscm = 3.5 In from each motor i.e. 3.5m In for m similar motors operating concu ...
Technical Teaching Equipment
Technical Teaching Equipment

7 Segment Display Driver
7 Segment Display Driver

... reverse voltage on the coil opposing current flow through the transistors base there for switching it off. Once the transistor is off the whole cycle continues. Although we know what happens here we need to have an idea of the second coils purpose. The second coil uses the change in magnetic fluxes ...
Paper Template
Paper Template

... Successful operation of power systems depends largely on the engineer's ability to provide reliable and uninterrupted service to the loads. Ideally, the loads must be fed from constant voltage and frequency sources at all times. This means that both voltage and frequency must be held within toleranc ...
Annex - B Technical Compliant Datasheet
Annex - B Technical Compliant Datasheet

Tektronix MBD: Products > High€Voltage Differential Probes P5200
Tektronix MBD: Products > High€Voltage Differential Probes P5200

... floating voltages up to 5,600 V (DC + pk AC) safely and has a bandwidth up to 50 MHz. It is supplied with two sizes of hook tips and has an overrange visual and oral indicator which warns the user when they are exceeding the linear range of the probe. It can be used with Tektronix TEKPROBETM interfa ...
Three Phase Diesel Generator 24Kw (28KVA)
Three Phase Diesel Generator 24Kw (28KVA)

... Number of cylinders ...
In Electric Circuits
In Electric Circuits

... exits the bottom of the battery, splits up to travel through R3 and R4, rejoins, then splits up again to travel through R1 and R2, then rejoins again to return to the top of the battery. There exists more than one path for current to travel (not series), yet there are more than two sets of electrica ...
factors that affect the charging time of a capacitor
factors that affect the charging time of a capacitor

Transformer Notes
Transformer Notes

Chapter 13: Inductance and Inductors
Chapter 13: Inductance and Inductors

APPLICATION BULLETIN
APPLICATION BULLETIN

DC to DC Converter (Switched Mode Power Supply) Design
DC to DC Converter (Switched Mode Power Supply) Design

... These produce a fixed output voltage when the input voltage is either higher or lower than the output voltage. Inverting Converter Design These produce a negative voltage from a positive voltage. Many text books call this type of converter a buck boost converter, however this nomenclature is normall ...
muddiest points Week 1
muddiest points Week 1

... that because electrons hold a negative charge, therefore current flows from the negative terminal to the positive terminal. It can be confusing when comparing relative voltages because a high positive voltage is actually a drain for electrons. I’m not sure if there’s really a good solution to this s ...
E10 Introduction to Engineering
E10 Introduction to Engineering

... The resistance between the center wiper terminal and either of the end terminals depends on the rotation angle of the shaft. A POT is rated by its end-to-end resistance and its power rating (the maximum power that it can dissipate without burning out). We have three types of POTs in the lab: 10Ω, 50 ...
lab sheet - Faculty of Engineering
lab sheet - Faculty of Engineering

Distribution Systems
Distribution Systems

... System Data Circuit. A Detroit Edison Company owned communication line, either open wire or cable, used for telephone or signal purposes. ...
PTD1 - Faculty of Engineering
PTD1 - Faculty of Engineering

Phillips Home Page
Phillips Home Page

lab sheet - Faculty of Engineering
lab sheet - Faculty of Engineering

... 2. Adjust the sending-end voltage E1 to 300 V and keep it constant for the reminder part of the experiment. Use a three-phase resistive load and increase the load in steps making sure that the loads are balanced. Take readings of sending end and receiving end voltages and powers, E1, Q1, P1, E2, Q2, ...
DEFINITIONS ABOUT THREE
DEFINITIONS ABOUT THREE

... Thus for a balanced system with 240V lines UL = 415V, and UP = 240V. For a balanced system no neutral wire is needed and even in a star supply the neutral wire can be left out. Only when the star connected loads are unbalanced will any current flow down the neutral, in a balanced system one of the o ...
Optimal Current Injection/Extraction for Electricity Distribution
Optimal Current Injection/Extraction for Electricity Distribution

< 1 ... 1894 1895 1896 1897 1898 1899 1900 1901 1902 ... 2014 >

Alternating current



Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report