• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Aggregation of Reactive Power
Aggregation of Reactive Power

... Service from any reactive power equipment including, for the avoidance of doubt, BM Units, Non-BM Units, Generating Units, Power Park Modules and other Plant and Apparatus or equipment. The various meter aggregation methodologies set out in this document (as amended or supplemented from time to time ...
COMMERCIAL ELECTRIC WATER HEATERS
COMMERCIAL ELECTRIC WATER HEATERS

... 1 DO NOT energize the branch circuit supplying power to the water heater or test the water heater electrical system before the water heater is completely filled with water. Read the start up procedures in the Instruction Manual that came with the water heater. 2 Be sure to turn off power and use a l ...
UL 1699
UL 1699

... altered in any way. All of UL’s Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means ...
Toward  integrated  plasmonic  circuits
Toward integrated plasmonic circuits

... the one-dimensional version of the cylindrical nanowire waveguide, which was one of the first to be identified for confining light to extraordinarily small lateral fields. However, it is the MIM geometry that has received the most attention owing to its ease of fabrication, even though the optical mode ...
Superconducting Fault Current Limiter 33kV SFCL Balance of Plant
Superconducting Fault Current Limiter 33kV SFCL Balance of Plant

Thermoelectric-Generator-Based DC- DC Conversion Network
Thermoelectric-Generator-Based DC- DC Conversion Network

SFH618A, SFH6186
SFH618A, SFH6186

... The SFH618A (DIP) and SFH6186 (SMD) feature a high current transfer ratio, low coupling capacitance and high isolation voltage. These couplers have a GaAs infrared diode emitter, which is optically coupled to silicon planar phototransistor detector, and is incorporated in a plastic DIP-4 or SMD pack ...
Features
Features

... low current consumption, without doing any special tricks. However, sometimes designers would like to reduce their system current even more by selectively disabling circuitry not being used. The patented DataGATE technology was developed to permit a straightforward approach to additional power reduc ...
Shielded Metal Arc Welding (SMAW) - Part A
Shielded Metal Arc Welding (SMAW) - Part A

... alternating occurs is measured as cycles per second, with 60cycle AC being the most common in North America. ...
WiFi Module Data Sheet
WiFi Module Data Sheet

... The phototransistor is used to receive BlinkUp configuration data. The bias resistor connected between OPTO_IN and GND may need to be adjusted to ensure adequate sensitivity and response time - in general you need at least 500mV swing on the OPTO_IN pin between black and white states, with the worst ...
installation instruction guide
installation instruction guide

... the limited numbers with safety capacity of electrical power. And please make the design based on stabilized parameters. ...
Remote Triggering of Paintball Markers
Remote Triggering of Paintball Markers

... Solid State A solid state relay (SSR) has no moving parts – it uses only electronic components. Some SSRs use optical coupling to provide isolation between the switching and switched circuits. The switching component is typically one or more metal–oxide–semiconductor field-effect transistors (MOSFET ...
5240 User's Manual
5240 User's Manual

... Plug the AC cord into the unit and into the wall outlet. Turn on the power switch located on the IPC, and the unit will power up, displaying the model information and firmware version number. Press the MENU button to enter the menu, and using the knob, turn to the right until the I Lim setting is di ...
S280-79-12
S280-79-12

... is shown in Figure 3. Line current flowing through the recloser is converted by the CPU module to a digital signal suitable for metering and fault current calculations. Data sampling occurs at a rate 32 times per cycle. The CPU contains a data acquisition section that uses the acquired samples to co ...
Suspended Bicore.
Suspended Bicore.

... oscillation-period of the slave is smaller than the oscillation-frequency of the master. The phasedifference between the master and the slave can be controlled by varying the oscillation-frequency of the master alone. This however can only be done to a certain extend since for a frequency which is t ...
controlo de um dirigível
controlo de um dirigível

MCP6V61/MCP6V61U Data Sheet
MCP6V61/MCP6V61U Data Sheet

Modular Smart Grid Power Systems Simulators (Utilities) AEL-MPSS Technical Teaching Equipment
Modular Smart Grid Power Systems Simulators (Utilities) AEL-MPSS Technical Teaching Equipment

... Due to the growth and development of electric power systems it has been required to design increasingly sophisticated devices to manage electric power in a safer and more efficient way. Nowadays, protection and monitoring devices, which allow to know the electrical parameters in real time, such as v ...
Atmel LED Drivers MSL2160/MSL2161
Atmel LED Drivers MSL2160/MSL2161

Ordering Information
Ordering Information

VS-UFB280FA20 Insulated Ultrafast Rectifier Module, 280 A
VS-UFB280FA20 Insulated Ultrafast Rectifier Module, 280 A

... Package indicator (SOT-227 standard insulated base) ...
EC6201
EC6201

caution - Liebert
caution - Liebert

... chains or cables from contacting cabinet by using spreader bar and adequate padding. Follow all battery safety precautions when installing, charging or servicing batteries. In addition to the hazard of electric shock, gas produced by batteries can be explosive and sulfuric acid can cause severe burn ...
MAX9209/MAX9213 Programmable DC-Balanced 21-Bit Serializers General Description
MAX9209/MAX9213 Programmable DC-Balanced 21-Bit Serializers General Description

... LVCMOS parallel input data to three LVDS outputs. A parallel rate clock on a fourth LVDS output provides timing for deserialization. The MAX9209/MAX9213 feature programmable DC balance, which allows isolation between the serializer and deserializer using AC-coupling. The DC balance circuits on each ...
General Specifications MODEL UT320 Digital Indicating Controller
General Specifications MODEL UT320 Digital Indicating Controller

< 1 ... 132 133 134 135 136 137 138 139 140 ... 2014 >

Alternating current



Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report