ADP3303 - Analog Devices
... The ADP3303 is a member of the ADP330x family of precision low dropout anyCAP 1 voltage regulators. The ADP3303 stands out from the conventional LDOs with a different architecture, an enhanced process, and a different package. Its patented design requires only a 0.47 µF output capacitor for stabilit ...
... The ADP3303 is a member of the ADP330x family of precision low dropout anyCAP 1 voltage regulators. The ADP3303 stands out from the conventional LDOs with a different architecture, an enhanced process, and a different package. Its patented design requires only a 0.47 µF output capacitor for stabilit ...
Introduction
... What is a Good Design? • Safety • Minimum Initial Investment • Maximum Electrical Efficiency (Minimum Operating Costs): e.g. power factor control, transformer loss, zoning lighting control ...
... What is a Good Design? • Safety • Minimum Initial Investment • Maximum Electrical Efficiency (Minimum Operating Costs): e.g. power factor control, transformer loss, zoning lighting control ...
DESIGN OF DC MACHINE
... i) Cost : the manufacturing cost of a machine with large core length, is less. This is because the proportion of inactive copper to active copper is smaller for grater the length of core. Therefore it is desirable to have large core length for less cost. ii) Ventilation: the ventilation of large cor ...
... i) Cost : the manufacturing cost of a machine with large core length, is less. This is because the proportion of inactive copper to active copper is smaller for grater the length of core. Therefore it is desirable to have large core length for less cost. ii) Ventilation: the ventilation of large cor ...
LTC3414 - 4A, 4MHz, Monolithic Synchronous Step-Down Regulator
... user should calculate the power dissipation when the LTC3414 is used at 100% duty cycle with low input voltages to ensure that thermal limits are not exceeded. Slope Compensation and Inductor Peak Current Slope compensation provides stability in constant frequency architectures by preventing subharm ...
... user should calculate the power dissipation when the LTC3414 is used at 100% duty cycle with low input voltages to ensure that thermal limits are not exceeded. Slope Compensation and Inductor Peak Current Slope compensation provides stability in constant frequency architectures by preventing subharm ...
MAX1639 High-Speed Step-Down Controller with Synchronous Rectification for CPU Power ________________General Description
... evaluation kit PC board layout as necessary. This circuit represents a good set of trade-offs between cost, size, and efficiency while staying within the worst-case specification limits for stress-related parameters, such as capacitor ripple current. The MAX1639 circuit was designed for the specifie ...
... evaluation kit PC board layout as necessary. This circuit represents a good set of trade-offs between cost, size, and efficiency while staying within the worst-case specification limits for stress-related parameters, such as capacitor ripple current. The MAX1639 circuit was designed for the specifie ...
ACS715 - Pololu
... solutions for DC current sensing in automotive systems. The device package allows for easy implementation by the customer. Typical applications include motor control, load detection and management, switch-mode power supplies, and overcurrent fault protection. ...
... solutions for DC current sensing in automotive systems. The device package allows for easy implementation by the customer. Typical applications include motor control, load detection and management, switch-mode power supplies, and overcurrent fault protection. ...
EMC filters 3-phase dv/dt output reactors 520 V AC, 8 1500 A, 40
... As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specifi ...
... As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specifi ...
Rodgers_HPM_Effects - TerpConnect
... for NQS and HF device operation. •Use nonlinear device and harmonic balance simulation mode (s>3). ...
... for NQS and HF device operation. •Use nonlinear device and harmonic balance simulation mode (s>3). ...
NCV891330 - 3 A, 2 MHz Low-Iq Dual-Mode Step-Down
... for Automotive The NCV891330 is a Dual Mode regulator intended for Automotive, battery−connected applications that must operate with up to a 45 V input supply. Depending on the output load, it operates either as a PWM Buck Converter or as a Low Drop−Out Linear Regulator, and is suitable for systems ...
... for Automotive The NCV891330 is a Dual Mode regulator intended for Automotive, battery−connected applications that must operate with up to a 45 V input supply. Depending on the output load, it operates either as a PWM Buck Converter or as a Low Drop−Out Linear Regulator, and is suitable for systems ...
ADN8810 12-Bit High Output Current Source (Rev. A) Data Sheet
... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to ab ...
... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to ab ...
CMD235C4 - Custom MMIC
... The CMD235C4 is a broadband MMIC SP5T switch housed in a leadless 4x4 mm surface mount package. The CMD235C4 covers DC to 18 GHz and offers a low insertion loss of 2.5 dB and high isolation of 40 dB at 10 GHz. The switch also includes an on board binary decoder circuit which reduces the number of re ...
... The CMD235C4 is a broadband MMIC SP5T switch housed in a leadless 4x4 mm surface mount package. The CMD235C4 covers DC to 18 GHz and offers a low insertion loss of 2.5 dB and high isolation of 40 dB at 10 GHz. The switch also includes an on board binary decoder circuit which reduces the number of re ...
ACTIONI/Q Q520 ® Loop Powered Multi-Channel T/C Input
... signal is usually monitored by a control system or data recorder. Typically, thermocouples are used to measure high temperatures such as in an oven or furnace. Thermocouple wires can be run a short distance to a panel, or farther with the use of shielded wire, without errors caused by noise or lead ...
... signal is usually monitored by a control system or data recorder. Typically, thermocouples are used to measure high temperatures such as in an oven or furnace. Thermocouple wires can be run a short distance to a panel, or farther with the use of shielded wire, without errors caused by noise or lead ...
3A1638
... Mounting: The SPD should be installed as close as possible to the device it is protecting. Good installation practice is to keep conductor length as short and straight as possible. The SPDs mount on a 35mm DIN-rail that should be securely mounted to the back of the panel’s interior using ¼ inch bolt ...
... Mounting: The SPD should be installed as close as possible to the device it is protecting. Good installation practice is to keep conductor length as short and straight as possible. The SPDs mount on a 35mm DIN-rail that should be securely mounted to the back of the panel’s interior using ¼ inch bolt ...
Chevy Volt Lear 3.3kW High Voltage Charger
... become available. In this way, you can also use other devices/BMS to monitor and control charging by interrupting the 12vdc supply to the Lear Charger Controller, if desired. ...
... become available. In this way, you can also use other devices/BMS to monitor and control charging by interrupting the 12vdc supply to the Lear Charger Controller, if desired. ...
International Electrical Engineering Journal (IEEJ)
... MPF, and switched capacitor compensators are [2-4]. The active power filters (APF) can also be used for power factor correction and loss reduction [5, 6]. In this paper a low cost design based on SCCS family of devices developed by the First Author is validated through digital simulation using Matla ...
... MPF, and switched capacitor compensators are [2-4]. The active power filters (APF) can also be used for power factor correction and loss reduction [5, 6]. In this paper a low cost design based on SCCS family of devices developed by the First Author is validated through digital simulation using Matla ...
Simple Direct Drive Kit Instructions
... Mark’s explanation of the circuitry is as follows First there are a few extra parts around U1, namely Q1, R2, R3, R4, R5. These parts are there to allow using a thermistor to keep the temperature of the MOSFETs under control. If R2 is replaced with a like resistance NTC thermistor and thermally conn ...
... Mark’s explanation of the circuitry is as follows First there are a few extra parts around U1, namely Q1, R2, R3, R4, R5. These parts are there to allow using a thermistor to keep the temperature of the MOSFETs under control. If R2 is replaced with a like resistance NTC thermistor and thermally conn ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).