TDK5111F 315 MHz ASK/FSK Transmitter in 10-pin Package
... Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effective ...
... Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effective ...
STTH30L06
... UNLESS EXPRESSLY APPROVED IN WRITING BY TWO AUTHORIZED ST REPRESENTATIVES, ST PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJU ...
... UNLESS EXPRESSLY APPROVED IN WRITING BY TWO AUTHORIZED ST REPRESENTATIVES, ST PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJU ...
How Batteries Work
... Tunneling is used to alter the placement of electrons in the floating gate. An electrical charge, usually 10 to 13 volts, is applied to the floating gate. The charge comes from the column, or bitline, enters the floating gate and drains to a ground. This charge causes the floating-gate transistor to ...
... Tunneling is used to alter the placement of electrons in the floating gate. An electrical charge, usually 10 to 13 volts, is applied to the floating gate. The charge comes from the column, or bitline, enters the floating gate and drains to a ground. This charge causes the floating-gate transistor to ...
AT140A/AT150A Installation Instructions
... The transformer can be mounted on an outlet box using the clamp on the primary end bell. The mounting plate is not used. To mount the transformer on an outlet box: 1. Turn the clamp screw almost all the way out. 2. From outside box, thread the primary leadwires through suitable 7/8 in. knockout. Fit ...
... The transformer can be mounted on an outlet box using the clamp on the primary end bell. The mounting plate is not used. To mount the transformer on an outlet box: 1. Turn the clamp screw almost all the way out. 2. From outside box, thread the primary leadwires through suitable 7/8 in. knockout. Fit ...
Form-Wound Coils Random
... are touching, this voltage can be as high as 114 volts (38 volts x a three-turn difference), and can be amplified by SCR loads. That is why random coils may prematurely fail. A similar form-coil design would have a peak voltage of only 38 volts because turns one and four would never be next to each ...
... are touching, this voltage can be as high as 114 volts (38 volts x a three-turn difference), and can be amplified by SCR loads. That is why random coils may prematurely fail. A similar form-coil design would have a peak voltage of only 38 volts because turns one and four would never be next to each ...
max17552atbevkit - Part Number Search
... The MAX17552 5V EV kit (TDFN) is a fully assembled and tested circuit board that demonstrates the performance of the MAX17552 60V, 100mA ultra-small, high-efficiency, synchronous step-down DC-DC converter in a 10-pin TDFN package. The EV kit operates over a wide input voltage range of 6V to 60V and ...
... The MAX17552 5V EV kit (TDFN) is a fully assembled and tested circuit board that demonstrates the performance of the MAX17552 60V, 100mA ultra-small, high-efficiency, synchronous step-down DC-DC converter in a 10-pin TDFN package. The EV kit operates over a wide input voltage range of 6V to 60V and ...
Control of Voltage Source Converters for Power
... conversion from ac to dc and vice versa. Appearance of Voltage Source Converter (VSC) makes use of more advanced semiconductor technology instead of thyristors. The VSC-based HVDC installations has several advantages compared to classic HVDC transmission such as independent control of active and rea ...
... conversion from ac to dc and vice versa. Appearance of Voltage Source Converter (VSC) makes use of more advanced semiconductor technology instead of thyristors. The VSC-based HVDC installations has several advantages compared to classic HVDC transmission such as independent control of active and rea ...
GB Masterys Green Power 100-120 Tender Document
... The static no-break power system will comprise n. … uninterruptible power supply unit or units (UPS ...
... The static no-break power system will comprise n. … uninterruptible power supply unit or units (UPS ...
EV2420-F-00A - Monolithic Power System
... zener diode is 6.5V. So VIN can be connected to EN through a high ohm resistor if the system doesn't have any other logic input acting as enable signal. The resistor needs to be designed to limit the EN pin sink current less than 150μA. Just note that there is an internal 3M resistor from EN to GND, ...
... zener diode is 6.5V. So VIN can be connected to EN through a high ohm resistor if the system doesn't have any other logic input acting as enable signal. The resistor needs to be designed to limit the EN pin sink current less than 150μA. Just note that there is an internal 3M resistor from EN to GND, ...
ISSCC 2015 / SESSION 22 / HIGH
... in Fig. 22.5.3(b), is powered from 1.1V, which allows it to achieve 10Gb/s modulation speed. From a 1.3V supply voltage both the gain and 3dB bandwidth are improved enabling 20Gb/s operation with energy efficiency of 0.58pJ/b. To compare single and multi-wavelength transmission, first we characteriz ...
... in Fig. 22.5.3(b), is powered from 1.1V, which allows it to achieve 10Gb/s modulation speed. From a 1.3V supply voltage both the gain and 3dB bandwidth are improved enabling 20Gb/s operation with energy efficiency of 0.58pJ/b. To compare single and multi-wavelength transmission, first we characteriz ...
Velocity and Motion sensors (1)
... distinguish between general back ground heat radiation and that given by a moving heat source. One arrangement is shown in the Fig. it consist of a single front electrode and two separate back electrodes. When the heat source moves from one electrode to the other, the resulting current through the r ...
... distinguish between general back ground heat radiation and that given by a moving heat source. One arrangement is shown in the Fig. it consist of a single front electrode and two separate back electrodes. When the heat source moves from one electrode to the other, the resulting current through the r ...
MAX44264 Ultra-Low Power Op Amp in a Tiny 6-Bump WLP General Description
... The common-mode input range of the MAX44264 extends down to ground, and offers excellent commonmode rejection. These devices are guaranteed not to undergo phase reversal when the input is overdriven. ...
... The common-mode input range of the MAX44264 extends down to ground, and offers excellent commonmode rejection. These devices are guaranteed not to undergo phase reversal when the input is overdriven. ...
MAX5186/MAX5189 Dual, 8-Bit, 40MHz, Current/Voltage, Simultaneous-Output DACs General Description
... The MAX5186/MAX5189 are designed to provide a high level of signal integrity for the least amount of power dissipation. Both DACs operate from a single supply voltage of 2.7V to 3.3V. Additionally, these DACs have three modes of operation: normal, low-power standby, and complete shutdown, which prov ...
... The MAX5186/MAX5189 are designed to provide a high level of signal integrity for the least amount of power dissipation. Both DACs operate from a single supply voltage of 2.7V to 3.3V. Additionally, these DACs have three modes of operation: normal, low-power standby, and complete shutdown, which prov ...
High-Performance, Cost-Effective VDMOS RF Power
... 0.97 reflection coefficient and a 0.25dB return loss, which equates to virtually a short or open circuit over all phase angles on the Smith Chart. Many industrial applications, such as plasma RF generators, present these mismatch loads under fault conditions, prior to protection circuitry action. Po ...
... 0.97 reflection coefficient and a 0.25dB return loss, which equates to virtually a short or open circuit over all phase angles on the Smith Chart. Many industrial applications, such as plasma RF generators, present these mismatch loads under fault conditions, prior to protection circuitry action. Po ...
Datasheet - 4116, (4x16) 1-wire Matrix - Giga
... 6U Form Factor – the larger 6U form factor will accommodate 3-4 times the number of relays as 3U PXI products eliminating the need to build switching structures across boards decreasing Bandwidth. Coaxially Shielded Reed Relays – • Shielding allows a characteristic 50Ω impedance to be maintai ...
... 6U Form Factor – the larger 6U form factor will accommodate 3-4 times the number of relays as 3U PXI products eliminating the need to build switching structures across boards decreasing Bandwidth. Coaxially Shielded Reed Relays – • Shielding allows a characteristic 50Ω impedance to be maintai ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).