LF198/LF298/LF398, LF198A/LF398A Monolithic Sample-and-Hold Circuits LF198/LF298/LF398, LF198A/LF398A
... Note 1: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. Note 2: The maximum power dissipation must be derated at elevated temperatures a ...
... Note 1: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. Note 2: The maximum power dissipation must be derated at elevated temperatures a ...
RF5189 3V, 2.45GHz LINEAR POWER AMPLIFIER Features
... The RF5189 is a two-stage device with a nominal gain of 25dB in the 2.4GHz to 2.5GHz ISM band. The RF5189 is designed primarily for IEEE802.11B WiFi applications where the available supply voltage and current are limited. This amplifier will operate to (and below) the lowest expected voltage made av ...
... The RF5189 is a two-stage device with a nominal gain of 25dB in the 2.4GHz to 2.5GHz ISM band. The RF5189 is designed primarily for IEEE802.11B WiFi applications where the available supply voltage and current are limited. This amplifier will operate to (and below) the lowest expected voltage made av ...
TS556
... Figure 7 shows actual waveforms generated in this mode of operation. The charge time (output HIGH) is given by: t1 = 0.693 (RA + RB) C and the discharge time (output LOW) by: t2 = 0.693 x RB x C Thus the total period T is given by: T = t1 + t2 = 0.693 (RA + 2RB) C The frequency of oscillation is the ...
... Figure 7 shows actual waveforms generated in this mode of operation. The charge time (output HIGH) is given by: t1 = 0.693 (RA + RB) C and the discharge time (output LOW) by: t2 = 0.693 x RB x C Thus the total period T is given by: T = t1 + t2 = 0.693 (RA + 2RB) C The frequency of oscillation is the ...
SCP6868-GL-#NE - Sumitomo Electric Europe Ltd
... 1) Tx Fault is an open collector output that shall be pulled up with a 4.7k - 10kΩ resistor on the host board. Pull up voltage between 2.0V and VccT+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. Tx Fault is asserted when bias current of laser exceeds t ...
... 1) Tx Fault is an open collector output that shall be pulled up with a 4.7k - 10kΩ resistor on the host board. Pull up voltage between 2.0V and VccT+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. Tx Fault is asserted when bias current of laser exceeds t ...
BU6904NUX - uri=media.digikey
... When using both small signal and large current GND patterns, it is recommended to isolate the two ground patterns, placing a single ground point at the ground potential of application so that the pattern wiring resistance and voltage variations caused by large currents do not cause variations in the ...
... When using both small signal and large current GND patterns, it is recommended to isolate the two ground patterns, placing a single ground point at the ground potential of application so that the pattern wiring resistance and voltage variations caused by large currents do not cause variations in the ...
UCC28810 数据资料 dataSheet 下载
... transformer zero energy. The transition is detected when the inductor current falls to zero and the TZE input goes low. Internal active clamps are provided to prevent TZE from going below ground or rising too high. If zero energy is not detected within 400 µs, a restart timer sets the latch and the ...
... transformer zero energy. The transition is detected when the inductor current falls to zero and the TZE input goes low. Internal active clamps are provided to prevent TZE from going below ground or rising too high. If zero energy is not detected within 400 µs, a restart timer sets the latch and the ...
BD6965NUX
... When using both small signal and large current GND patterns, it is recommended to isolate the two ground patterns, placing a single ground point at the ground potential of application so that the pattern wiring resistance and voltage variations caused by large currents do not cause variations in the ...
... When using both small signal and large current GND patterns, it is recommended to isolate the two ground patterns, placing a single ground point at the ground potential of application so that the pattern wiring resistance and voltage variations caused by large currents do not cause variations in the ...
TPS2043, TPS2053
... of the MOSFET above the source. The charge pump operates from input voltages as low as 2.7 V and requires very little supply current. driver The driver controls the gate voltage of the power switch. To limit large current surges and reduce the associated electromagnetic interference (EMI) produced, ...
... of the MOSFET above the source. The charge pump operates from input voltages as low as 2.7 V and requires very little supply current. driver The driver controls the gate voltage of the power switch. To limit large current surges and reduce the associated electromagnetic interference (EMI) produced, ...
12-bit, serial IN, parallel OUT driver
... Application circuit diagrams and circuit constants contained herein are shown as examples of standard use and operation. Please pay careful attention to the peripheral conditions when designing circuits and deciding upon circuit constants in the set. Any data, including, but not limited to applicati ...
... Application circuit diagrams and circuit constants contained herein are shown as examples of standard use and operation. Please pay careful attention to the peripheral conditions when designing circuits and deciding upon circuit constants in the set. Any data, including, but not limited to applicati ...
95-6571 - L8124A,C,E,L and M Aquastat® Relays
... temperature changes in the boiler water. L8124 can provide multizone control by using a separate circulator and R845 Relay for each zone. L8124E and L have large transformers and extra terminals for supplying power to low voltage valves. L8124L includes a large transformer and extra terminals for lo ...
... temperature changes in the boiler water. L8124 can provide multizone control by using a separate circulator and R845 Relay for each zone. L8124E and L have large transformers and extra terminals for supplying power to low voltage valves. L8124L includes a large transformer and extra terminals for lo ...
LMC555 CMOS Timer (Rev. M)
... When operated as a one-shot, the time delay is precisely controlled by a single external resistor and capacitor. In the astable mode, the oscillation frequency and duty cycle are accurately set by two external resistors and one capacitor. The use of TI’s LMCMOS process extends both the frequency ran ...
... When operated as a one-shot, the time delay is precisely controlled by a single external resistor and capacitor. In the astable mode, the oscillation frequency and duty cycle are accurately set by two external resistors and one capacitor. The use of TI’s LMCMOS process extends both the frequency ran ...
ADP5033 英文数据手册DataSheet 下载
... rejection greater than 60 dB for frequencies as high as 10 kHz while operating with a low headroom voltage. ...
... rejection greater than 60 dB for frequencies as high as 10 kHz while operating with a low headroom voltage. ...
Student Study Aids
... Problem: Why can arcing be a problem when coils are used in switching circuits? Answer: A demonstration of producing a high voltage by opening an inductive circuit is shown in Figure 22-3 (page 656 of the text). 1. With the switch, S, closed, the applied voltage, V, of 8 V is not enough to light the ...
... Problem: Why can arcing be a problem when coils are used in switching circuits? Answer: A demonstration of producing a high voltage by opening an inductive circuit is shown in Figure 22-3 (page 656 of the text). 1. With the switch, S, closed, the applied voltage, V, of 8 V is not enough to light the ...
LT5537 - Wide Dynamic Range RF/IF Log Detector.
... terminate the input signal with a 50Ω resistor and AC couple it to one of the input pins while AC grounding the other input pin (Figure 13). The sensitivity (defined as the minimum input power required for the output to be within 3dB of the ideal log-linear response) is –76.4dBm at 200MHz in this ca ...
... terminate the input signal with a 50Ω resistor and AC couple it to one of the input pins while AC grounding the other input pin (Figure 13). The sensitivity (defined as the minimum input power required for the output to be within 3dB of the ideal log-linear response) is –76.4dBm at 200MHz in this ca ...
UCC28050 数据资料 dataSheet 下载
... Additionally, the controller provides features such as peak current limit, default timer, overvoltage protection (OVP) and enable. The UCC38050 and UCC38051, while being pin compatible with other industry controllers providing similar functionality, offer many feature enhancements and tighter specif ...
... Additionally, the controller provides features such as peak current limit, default timer, overvoltage protection (OVP) and enable. The UCC38050 and UCC38051, while being pin compatible with other industry controllers providing similar functionality, offer many feature enhancements and tighter specif ...